Back to Authors

Inglis, Sara S

0000-0003-3200-3575

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 15

Biventricular Pressure‐Volume Loop Analysis in an LVAD Patient Optimized With Impella RP Flex

Catheterization and Cardiovascular Interventions | October 1, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.70929 | PMID 42820845

ABSTRACT Right ventricular (RV) failure after left ventricular assist device (LVAD) implantation is a serious complication which may necessitate temporary mechanical support in refractory cases. Here we describe a 63‐year‐old man with end‐stage ischemic cardiomyopathy and severe combined pre‐ and post‐capillary pulmonary hypertension who developed persistent RV failure post‐LVAD. He was intolerant to speed optimization secondary to preload mismatch, and invasive hemodynamics confirmed LV underfilling. An Impella RP Flex was placed for RV support, and biventricular (BiV) pressure‐volume (PV) loops were utilized to ascertain hemodynamic response. With increasing Impella RP Flex support, left ventricular end‐diastolic volume increased with subsequent improvement in left ventricular performance. This case represents the first reported use of BiV PV loop analysis to characterize the physiological effects of Impella RP Flex in a patient with LVAD support, underscoring its utility in understanding device‐ventricular interactions.
Biventricular Pressure–Volume Loop Assessment of Impella 5.5 in an Acute ST‐Segment–Elevation Myocardial Infarction Shock Model Unmasks Diminished Right Ventricular Reserve

Journal of the American Heart Association | September 25, 2026 | Volume: 15 | Issue: 19 | Pages: No page available

10.1161/jaha.125.047609 | PMID 42786601

Background The Impella 5.5 is employed to provide left ventricular support in cardiogenic shock. Mechanistic understanding of biventricular relationships is essential in device optimization. Using a porcine model of acute myocardial infarction in tandem with pressure–volume loops, this study aimed to understand the impact of Impella 5.5 on biventricular hemodynamics. Methods Using Domestic Yorkshire pigs, an Impella 5.5 was inserted percutaneously under fluoroscopic guidance via carotid/aortic access and an acute myocardial infarction was created. Biventricular pressure–volume loops and derived parameters were generated for each level of support before (n=6) and after myocardial infarction (n=6). Results With increasing Impella 5.5 support, left ventricular pressure–volume loops shifted left, and right ventricular (RV) loops shifted right. In a healthy porcine heart, the RV adequately compensated for increased preload from the device, demonstrated by increased RV performance at higher P levels. After myocardial infarction, pigs were unable to tolerate speeds beyond P7 from diminished RV stroke volume reserve compared to healthy hearts. Median RV stroke volume percentage change from P1 to P9 before myocardial infarction was from 5.7% (interquartile range, −15.1% to 9.7%) to 50.6% (interquartile range, −11.6% to 60.2; P <0.05), and following acute myocardial infarction from P1 to P7 was from 3.9% (interquartile range, −2.7 to 78.4) to 13.4% (interquartile range, −8.9% to 147.2; P =0.94). Conclusions Impella 5.5 speed modulation highlights significant interventricular interactions with opposing biventricular trends. While the heart can mount an improvement in RV stroke volume with increasing Impella 5.5 support, these data suggest an attenuated response following acute myocardial infarction, which may relate to inadequate response to increased preload needed by the device after infarction affecting the interventricular septum.
A Novel Low-Profile Full-Flow Percutaneous Ventricular Assist Device

ASAIO Journal | October 8, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/mat.0000000000002564 | PMID 41076727

Percutaneous ventricular assist devices (pVAD) decrease mortality in cardiogenic shock (CS) patients, but at a high adverse event rate. Novel pVADs need to improve cardiac power output (CPO) to improve efficacy and reduce profile to reduce adverse events. Venstramedical has developed an impeller with nitinol and polymer which can collapse for low-profile insertion and expand in the body to provide optimal CPO. We have also developed a unique 9 French (9Fr) delivery system. In vitro and in vivo testing have been performed to develop this device. Head-flow (HQ) tests generate 5.0 L/min with a pressure differential of 80 mm Hg and 7.0 L/min against 60 mm Hg. Durability testing demonstrated continuous operation of up to 20 days. In the acute healthy ovine model, we demonstrated full flow (7–9 L against 60–80 mm Hg), transcatheter 9Fr delivery, retrieval of the device, and resting of the native heart during pumping. In a CS animal, we demonstrated survival and resting of the native heart during the acute study with decreased stroke work (SW), decreased stroke volume (SV), while total cardiac output was up to 7 L/min and maintaining adequate pressure with low hemolysis. We also demonstrated multiday functioning of the device in a healthy ovine model with good CO and low hemolysis.
Atrioventricular Dyssynchrony and Dyspnea in Heart Failure With Preserved Ejection Fraction

Circulation: Heart Failure | May 19, 2025 | Volume: 18 | Issue: 7 | Pages: No page available

10.1161/circheartfailure.125.013183 | PMID 40384453

Impact of glucagon-like peptide-1 receptor agonists on hypertension management: a narrative review

Current Opinion in Cardiology | May 1, 2025 | Volume: 40 | Issue: 4 | Pages: 185-192

10.1097/hco.0000000000001225 | PMID 40305149

Purpose of review The increasing prevalence of hypertension, alongside the growing use of glucagon-like peptide-1 receptor agonists (GLP-1 RAs) for conditions beyond type 2 diabetes, underscores the need for understanding if there is a role for these medications in blood pressure management. This review addresses the timely opportunity to assess how GLP-1 RAs could influence blood pressure control, potentially broadening therapeutic strategies for cardiovascular risk management. Recent findings Emerging literature indicates that GLP-1 RAs influence blood pressure through various mechanisms, such as sympathetic nervous modulation, vasodilation, and diuretic effects. Clinical trials demonstrate modest yet statistically significant reductions in systolic blood pressure (SBP), with less consistent effects on diastolic blood pressure (DBP). The advent of dual GLP-1 and glucose-dependent insulinotropic polypeptide (GIP) receptor agonists presents enhanced possibilities for managing hypertension. Summary The implications of these findings suggest that GLP-1 RAs have potential as adjunctive therapies for hypertension, especially in patients already receiving these agents for other cardiometabolic conditions. The blood pressure-lowering effects, often independent of weight loss or glucose control, warrant further investigation to determine their precise role within hypertension treatment algorithms and encourage integration into clinical practice.
Assessment of Left‐Sided Hemodynamics With Exercise in Patients With Continuous Flow Left Ventricular Assist Device Support

Artificial Organs | March 13, 2025 | Volume: 49 | Issue: 9 | Pages: 1462-1469

10.1111/aor.14995 | PMID 40078038

ABSTRACT Background Addition of left heart catheterization (LHC) to exercise protocols allows for a unique focus on parameters of systolic and diastolic responses to increased activity in patients with left ventricular assist device (LVAD) support. Methods A retrospective review was conducted of all consecutive adult patients who underwent LHC with exercise for any indication from June 2017 to June 2023. For all patients, the relationship between exercise and parameters of LV systolic and diastolic response was assessed. Patients were divided into two cohorts based on the indication for testing: hemodynamic optimization (Optim, n = 5) or weaning consideration (Wean, n = 3). Results Eight patients (88% male, median age 57 years (IQR 44, 65)) were included. LVEF was 45% (IQR 45, 56) in Wean and 25% (IQR 20, 42) in Optim. LV systolic work index (LVSWI) increased more rapidly over levels of exercise in Wean vs. Optim (slope 46.3 vs. −0.625; p = 0.044) and LVSWI rose more quickly at lower levels of LV end diastolic pressure (LVEDP) in Wean vs. Optim (slope 219.5 vs. −2.008; p = 0.0026). Pulse power index was higher in Wean patients at baseline (0.046 (IQR 0.04, 0.07) vs. 0.016 (IQR 0.001, 0.04); p = 0.14) and peak exercise (0.12 (IQR 0.12, 0.12) vs. 0.06 (IQR 0.03, 0.1); p = 0.29). Conclusions Patients with favorable remodeling on LVAD support have significantly improved LV systolic and diastolic responses to exercise and a trend of higher systemic pulsatility. Improving our understanding of LV‐LVAD interactions with activity may aid in future efforts to improve exercise tolerance through speed modulation.
Reduction in Balloon Pump Size Reduces Axillary Intraaortic Balloon Pump Failure Risk

ASAIO Journal | July 8, 2024 | Volume: 71 | Issue: 1 | Pages: 68-74

10.1097/mat.0000000000002268 | PMID 38976860

Axillary artery intra-aortic balloon pump (axIABP) placement has been implemented as a bridging solution before heart transplantation. This study evaluates complications associated with axIABP support and describes an approach to minimize adverse events. We previously described a percutaneous approach for axIABP placement. However, patients receiving axIABP between September 1, 2017, and September 26, 2019 (n = 32) demonstrated a high rate of balloon pump malfunction (8/32; 25%) and other complications (totaling 15/32; 47%). Sixty-four patients were sequentially treated under a revised protocol. Compared to the initial cohort, no significant differences in demographics were noted. A significant reduction in rate of balloon malfunction (8/32, 25% vs. 1/64, 2%; p < 0.001) and total complications (15/32, 47% vs. 10/64, 16%; p = 0.0025) during the period of support were noted after intervention. Subsequent analysis of total complications per device size (40 vs. ≤ 34 ml balloon) revealed significantly reduced complications in patients with smaller devices (40% vs. 13%, respectively; p = 0.0022). This study provides guidelines to limit complications in patients supported with axIABP, facilitating a protracted period of bridging support.
Infliximab Limits Injury in Myocardial Infarction

Journal of the American Heart Association | May 3, 2024 | Volume: 13 | Issue: 9 | Pages: No page available

10.1161/jaha.123.032172 | PMID 38700022

Background The purpose of this study was to investigate a therapeutic approach targeting the inflammatory response and consequent remodeling from ischemic myocardial injury. Methods and Results Coronary thrombus aspirates were collected from patients at the time of ST‐segment–elevation myocardial infarction and subjected to array‐based proteome analysis. Clinically indistinguishable at myocardial infarction (MI), patients were stratified into vulnerable and resilient on the basis of 1‐year left ventricular ejection fraction and death. Network analysis from coronary aspirates revealed prioritization of tumor necrosis factor‐α signaling in patients with worse clinical outcomes. Infliximab, a tumor necrosis factor‐α inhibitor, was infused intravenously at reperfusion in a porcine MI model to assess whether infliximab‐mediated immune modulation impacts post‐MI injury. At 3 days after MI (n=7), infliximab infusion increased proregenerative M2 macrophages in the myocardial border zone as quantified by immunofluorescence (24.1%±23.3% in infliximab versus 9.29%±8.7% in sham; P <0.01). Concomitantly, immunoassays of coronary sinus samples quantified lower troponin I levels (41.72±7.34 pg/mL versus 58.11±10.75 pg/mL; P <0.05) and secreted protein analysis revealed upregulation of injury‐modifying interleukin‐2, ‐4, ‐10, ‐12, and ‐18 cytokines in the infliximab‐treated cohort. At 4 weeks (n=12), infliximab treatment resulted in significant protective influence, improving left ventricular ejection fraction (53.9%±5.4% versus 36.2%±5.3%; P <0.001) and reducing scar size (8.31%±10.9% versus 17.41%±12.5%; P <0.05). Conclusions Profiling of coronary thrombus aspirates in patients with ST‐segment–elevation MI revealed highest association for tumor necrosis factor‐α in injury risk. Infliximab‐mediated immune modulation offers an actionable pathway to alter MI‐induced inflammatory response, preserving contractility and limiting adverse structural remodeling.
Biventricular catheterization combined with pressure‐volume loop monitoring provides insight into the dynamic effects of left ventricular assist devices ramp on right ventricular function

Catheterization and Cardiovascular Interventions | March 10, 2024 | Volume: 103 | Issue: 5 | Pages: 799-802

10.1002/ccd.30993 | PMID 38461378

AbstractRamp studies are utilized for speed optimization of continuous flow left ventricular assist devices (CF‐LVADs). We here report the utility of combined left and right heart catheterization during a ramp study to ensure a comprehensive understanding of the hemodynamic implications on both ventricles. Pressure‐volume loop (PV loop) monitoring uncovered compromised systolic and mildly compromised right ventricular function with increasing LVAD speeds, despite improvement in left ventricular unloading. These findings informed patient management and highlight the potential utility of PV loop monitoring as an adjunct to left and right heart catheterization during ramp studies of next‐generation LVADs.
Professional Employment With Left Ventricular Assist Device Support: Does Working With an LVAD Allow It to Work Too?

ASAIO Journal | March 8, 2024 | Volume: 70 | Issue: 5 | Pages: 356-357

10.1097/mat.0000000000002187 | PMID 38457524