Citations 6

0895 Pediatric Positive Pressure Therapy: Enhancing Education And Parent/guardian Confidence To Implement Therapy

Sleep | May 27, 2020 | Volume: 43 | Issue: Supplement_1 | Pages: A341-A341

10.1093/sleep/zsaa056.891

Abstract Introduction Pediatric positive airway pressure (PAP) therapy can be challenging for children and their parent/guardian (PG). These challenges are complicated by the need to facilitate behavioral competency in the management of both device equipment and therapy. Methods As part of a larger quality management project aimed to improve PG and patient satisfaction we developed a targeted education visit provided by registered nurses prior to PAP trial initiation. Principle aims were to measure satisfaction with education and increase PG confidence in ability to manage therapy. The nurse session included: education on Obstructive Sleep Apnea (OSA) and PAP therapy, development of plan for first month of therapy, concepts of desensitization, regular practice, discussion and identification of concerns (assessment of barriers to implementation). A survey was administered pre-intervention to assess PG confidence in ability to manage therapy. Post-intervention, PG rated the interventions impact on baseline confidence, as well as an assessment of satisfaction with the education and content. Descriptive statistics were utilized to summarize the Likert survey questions. Results A total of 21of 25 (84%) participants completed surveys. 100% of PG that responded was either extremely satisfied or very satisfied with the educational intervention. Prior to the intervention, 19% (N4) indicated little to no confidence, 19% (N4) indicated some confidence and 62% (N13) indicated being very confident. 62% (N13) of PG’s indicated the information covered was new to them, while 24% (N5) indicated some information was new and 14% (N3) indicated none of the information was new. Regardless of baseline confidence, 100% (N21) responded that the intervention further improved confidence to a great degree. Conclusion The nurse visit resulted in high satisfaction with care and education and impacted PG confidence in ability to implement treatment. Future studies are needed to determine the impact on patient compliance. Support
Enhancing the patient and family experience during pediatric sleep studies

Journal of Clinical Sleep Medicine | February 17, 2020 | Volume: 16 | Issue: 7 | Pages: 1037-1043

10.5664/jcsm.8386 | PMID 32065112

0966 Navigating the Path to Primary Care Involvement in the Care of Stable Obstructive Sleep Apnea Patients

Sleep | April 13, 2019 | Volume: 42 | Issue: Supplement_1 | Pages: A388-A389

10.1093/sleep/zsz067.963

1056 Exploring the Impact of a Sleep Enhancement Program in the Inpatient Environment on Patient Satisfaction: Lessons Learned

Sleep | April 27, 2018 | Volume: 41 | Issue: suppl_1 | Pages: A393-A393

10.1093/sleep/zsy061.1055

Characterizing the Emotions That Trigger Cataplexy

The Journal of Neuropsychiatry and Clinical Neurosciences | December 17, 2014 | Volume: 17 | Issue: 1 | Pages: 45-50

10.1176/jnp.17.1.45 | PMID 15746482

The oesophageal string test: a novel, minimally invasive method measures mucosal inflammation in eosinophilic oesophagitis

Gut | August 15, 2012 | Volume: 62 | Issue: 10 | Pages: 1395-1405

10.1136/gutjnl-2012-303171 | PMID 22895393

Objective Eosinophil predominant inflammation characterises histological features of eosinophilic oesophagitis (EoE). Endoscopy with biopsy is currently the only method to assess oesophageal mucosal inflammation in EoE. We hypothesised that measurements of luminal eosinophil-derived proteins would correlate with oesophageal mucosal inflammation in children with EoE. Design The Enterotest diagnostic device was used to develop an oesophageal string test (EST) as a minimally invasive clinical device. EST samples and oesophageal mucosal biopsies were obtained from children undergoing upper endoscopy for clinically defined indications. Eosinophil-derived proteins including eosinophil secondary granule proteins (major basic protein-1, eosinophil-derived neurotoxin, eosinophil cationic protein, eosinophil peroxidase) and Charcot–Leyden crystal protein/galectin-10 were measured by ELISA in luminal effluents eluted from ESTs and extracts of mucosal biopsies. Results ESTs were performed in 41 children with active EoE (n=14), EoE in remission (n=8), gastro-oesophageal reflux disease (n=4) and controls with normal oesophagus (n=15). EST measurement of eosinophil-derived protein biomarkers significantly distinguished between children with active EoE, treated EoE in remission, gastro-oesophageal reflux disease and normal oesophagus. Levels of luminal eosinophil-derived proteins in EST samples significantly correlated with peak and mean oesophageal eosinophils/high power field (HPF), eosinophil peroxidase indices and levels of the same eosinophil-derived proteins in extracts of oesophageal biopsies. Conclusions The presence of eosinophil-derived proteins in luminal secretions is reflective of mucosal inflammation in children with EoE. The EST is a novel, minimally invasive device for measuring oesophageal eosinophilic inflammation in children with EoE.