Abstract Background Cardiac magnetic resonance elastography (MRE) allows the non-invasive quantification of myocardial stiffness, but long-interval reproducibility data at 3.0 T single-frequency 140-Hz remain limited. Purpose To evaluate the short- and long-interval reproducibility of 3.0 T cardiac MRE for left ventricular (LV) myocardial stiffness across healthy volunteers and patients with conditions associated with elevated myocardial stiffness. Materials and Methods This prospective single-center study included 69 participants: 60 healthy volunteers and 9 with cardiovascular disease (6 with aortic stenosis and 3 with long-standing hypertension). All participants underwent baseline cardiac MRE (scanner: Signa Premier 3.0 T, GE Healthcare, driver: Resoundant), an immediate short-interval rescan (SIR) within 5 minutes, and a long-interval rescan (LIR) after approximately 1 month. Left ventricular myocardial stiffness and octahedral shear strain signal-to-noise ratio were measured independently by 2 readers. Reproducibility was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), within-subject coefficient of variation, standard error of measurement, and smallest detectable change at the 95% confidence (SDC95) level. Results Baseline LV myocardial stiffness was higher in the disease group than in healthy volunteers, 11.73 ± 1.01 kPa and 7.80 ± 0.70 kPa (mean ± SD; P < .001), respectively. Inter-reader agreement was excellent across all timepoints, with ICCs of 0.970 at baseline (95% CI, 0.953-0.982), 0.966 for SIR (95% CI, 0.945-0.979), and 0.962 for LIR (95% CI, 0.939-0.976). Within-reader scan-rescan reproducibility was also excellent. For Reader 1, stiffness ICC was 0.979 for the SIR (95% CI, 0.966-0.987) and 0.957 for the LIR (95% CI, 0.932-0.973), with SDC95 values of 0.616 kPa (95% CI, 0.528-0.741) and 0.869 kPa (95% CI, 0.744-1.044), respectively. Reader 2 showed excellent reproducibility, with ICCs ≤0.943. Conclusions 3D single-frequency 140-Hz cardiac MRE at 3.0 T provides excellent short- and long-interval reproducibility for LV myocardial stiffness quantification. The SDC95 values may help distinguish true longitudinal stiffness changes from measurement variability.
Comparing Harmonization Approaches for Protocol-Related Variability in Multisite Diffusion MRI Data
No container title available | July 11, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
Diffusion MRI (dMRI) enables assessment of white matter microstructural abnormalities in Alzheimer's disease (AD), and multisite datasets enable more robust modeling of non-biological variation that can confound analyses. The Alzheimer's Disease Neuroimaging Initiative (ADNI) includes over 10 dMRI protocols, necessitating robust methods to model protocol-related variability when pooling data. Here, we compared three harmonization approaches: (1) mixed-effects models, (2) ComBat-GAM, and (3) eHarmonize, a reference-based lifespan method. We assessed their ability to reduce protocol-related variability in diffusion tensor imaging fractional anisotropy (FA) and mean diffusivity (MD) while preserving associations with cognitive impairment (CI), and amyloid-beta (Aβ) and tau PET burden in 1,086 ADNI3/4 participants. All approaches yielded more closely aligned FA/MD distributions across protocols. Associations with clinical indicators of CI were highly consistent across approaches, whereas PET associations were less widespread and more variable. Overall, multiple strategies effectively modeled protocol-related variability while preserving AD-related associations.