ABSTRACT Understanding how some HIV-infected cells resist the cytotoxicity of HIV replication is crucial to enabling HIV cure efforts. HIV killing of CD4 T cells that replicate HIV can involve HIV protease-mediated cleavage of procaspase 8 to generate a fragment (Casp8p41) that directly binds and activates the mitochondrial proapoptotic protein BAK. Here, we demonstrate that Casp8p41 also binds with nanomolar affinity to the antiapoptotic protein Bcl-2, which sequesters Casp8p41 and prevents apoptosis. Further, we show that central memory CD4 T cells (T CM ) from HIV-infected individuals have heightened expression of BCL-2 relative to procaspase 8, possibly explaining the persistence of HIV-infected T CM despite generation of Casp8p41. Consistent with this hypothesis, the selective BCL-2 antagonist venetoclax induced minimal killing of uninfected CD4 T cells but markedly increased the death of CD4 T cells and diminished cell-associated HIV DNA when CD4 T cells from antiretroviral therapy (ART)-suppressed HIV patients were induced with αCD3/αCD28 to reactivate HIV ex vivo . Thus, priming CD4 T cells from ART suppressed HIV patients with a BCL-2 antagonist, followed by HIV reactivation, achieves reductions in cell-associated HIV DNA, whereas HIV reactivation alone does not. IMPORTANCE HIV infection is incurable due to a long-lived reservoir of HIV + memory CD4 T cells, and no clinically relevant interventions have been identified that reduce the number of these HIV DNA-containing cells. Since postintegration HIV replication can result in HIV protease generation of Casp8p41, which activates BAK, causing infected CD4 T cell death, we sought to determine whether this occurs in memory CD4 T cells. Here, we demonstrate that memory CD4 T cells can generate Casp8p41 and yet are intrinsically resistant to death induced by diverse stimuli, including Casp8p41. Furthermore, BCL-2 expression is relatively increased in these cells and directly binds and inhibits Casp8p41's proapoptotic effects. Antagonizing BCL-2 with venetoclax derepresses this antagonism, resulting in death, preferentially in HIV DNA containing cells, since only these cells generate Casp8p41. Thus, BCL-2 antagonism is a clinically relevant intervention with the potential to reduce HIV reservoir size in patients.
Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory
Journal of Clinical Microbiology | May 15, 2014 | Volume: 52 | Issue: 7 | Pages: 2689-2693
ABSTRACT Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved.
Evaluation of the Abbott HBV RUO Sequencing Assay Combined with Laboratory-Modified Interpretive Software
Journal of Clinical Microbiology | October 25, 2012 | Volume: 51 | Issue: 1 | Pages: 95-100
ABSTRACTThe Abbott HBV RUO Sequencing assay (Abbott Molecular Inc., Des Plaines, IL), which combines automated sample processing, real-time PCR, and bidirectional DNA sequencing, was evaluated for detection of nucleos(t)ide analogue (NA) resistance-associated mutations located in the hepatitis B virus (HBV) polymerase (Pol) gene. Interpretive software from the assay manufacturer was modified to allow interrogation of the overlapping HBV surface (S) gene sequence for HBV genotype determination and detection of immune escape mutations. Analytical sensitivity (detection and sequencing) of the assay was determined to be 103.9 IU/ml (95% confidence interval [CI], 80.0 to 173.3) for HBV genotype A. Testing of commercially available HBV genotype panels consisting of 23 individual members yielded complete agreement between expected results and results obtained from the laboratory-developed HBV genotype library. Excellent specificity was observed among clinical specimens with serologic or molecular markers for various unrelated blood-borne viruses (n= 6) and sera obtained from healthy, HBV-negative blood donors (n= 20). Retrospectively selected clinical specimens tested by a commercial reference laboratory HBV sequencing assay (n= 54) or the TrugeneHBVGenotyping kit (n= 7) and the Abbott HBV RUO Sequencing assay showed minor differences in detection and reporting of NA resistance-associated mutations in 7 of 61 (11.5%) specimens but complete agreement of genotype results. The Abbott HBV RUO Sequencing assay provided a convenient and efficient assay workflow suitable for routine clinical laboratory use, with the flexibility to be modified for customized detection of NA resistance-associated mutations, HBV genotype determination, and detection of immune escape mutations from a single contiguous HBV sequence.
Hepatitis C Virus Genotypes in Clinical Specimens Tested at a National Reference Testing Laboratory in the United States
Journal of Clinical Microbiology | May 26, 2011 | Volume: 49 | Issue: 8 | Pages: 3040-3043
ABSTRACTHepatitis C virus (HCV) genotype (GT) distribution and frequency were studied among 22,407 unique specimens tested at a national reference testing laboratory. Subjects with HCV GT 3 were younger (P< 0.0001) than those with GT 1, 2, or 4, and the regional frequencies of HCV GT 2 and 3 ranged from 19.9% to 29.2%.
Results of the Abbott RealTi
m
e HIV-1 Assay for Specimens Yielding “Target Not Detected” Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test
Journal of Clinical Microbiology | December 31, 2009 | Volume: 48 | Issue: 3 | Pages: 969-971
ABSTRACT No significantly discordant results were observed between the Abbott RealTi m e HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding “target not detected” results by CTM.
Detection and Quantification of Hepatitis C Virus (HCV) by MultiCode-RTx Real-Time PCR Targeting the HCV 3′ Untranslated Region
Journal of Clinical Microbiology | June 18, 2009 | Volume: 47 | Issue: 8 | Pages: 2635-2638
ABSTRACT A prototype, real-time reverse-transcription PCR assay, based on MultiCode-RTx technology, quantifying hepatitis C virus (HCV) RNA by targeting the HCV 3′ untranslated region demonstrated linearity over 7 logs, with a good correlation between the quantitative results of this assay and the results of two commercially available comparator assays for 466 clinical specimens comprising all six HCV genotypes.
Anomalous Quantitation Standard Growth Curves in a Laboratory-Developed Hepatitis C Virus (HCV) RNA Quantification Assay Using the TaqMan HCV Analyte-Specific Reagent
Journal of Clinical Microbiology | May 7, 2009 | Volume: 47 | Issue: 7 | Pages: 2317-2320
ABSTRACT A retrospective examination of quantitation standard growth curves associated with 1,000 unique clinical serum specimens tested by a laboratory-developed TaqMan hepatitis C virus analyte-specific reagent-based assay revealed anomalous growth curves associated with 0.40% (95% confidence interval, 0.11% to 1.00%) of these specimens.
Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
Journal of Clinical Microbiology | February 5, 2009 | Volume: 47 | Issue: 4 | Pages: 889-895
ABSTRACT The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results ( r = 0.95) among clinical specimens, with a mean difference of −0.34 log 10 copies/ml. Testing of healthy donor plasma specimens yielded “target not detected” results by ART, with “HIV-1 RNA detected, <40 copies/ml” results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively ( P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively ( P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.
Plasma Load Discrepancies between the Roche Cobas Amplicor Human Immunodeficiency Virus Type 1 (HIV-1) Monitor Version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Assays
Journal of Clinical Microbiology | February 5, 2008 | Volume: 46 | Issue: 2 | Pages: 834-834