BACKGROUND: Cardiac computed tomography (CT) acquired during the acute stroke imaging protocol is an emerging modality to detect cardiac thrombi. We determined its yield in patients with acute ischemic stroke. METHODS: We performed a 1-stage individual patient data meta-analysis of 4 prospective observational cohorts (AIS of HEARTS [Acute Ischemic Stroke of Heart-Related Embolic Sources Detected on Acute Cardiac CT Scans]), including patients with acute ischemic stroke who underwent ECG-gated or non–ECG-gated cardiac CT between May 2018 and June 2024. We excluded patients with transient ischemic attack or stroke mimics. The primary outcome was the proportion of patients with a thrombus on cardiac CT. Secondary outcomes were additional scan time, radiation dose, comparison with echocardiography, and 90-day outcomes. We performed logistic regression analyses to compare 90-day outcomes between patients with and without thrombus, adjusting for age, sex, history of atrial fibrillation, ischemic heart disease, chronic heart failure, stroke or transient ischemic attack, anticoagulant use, prestroke modified Rankin Scale score, National Institutes of Health Stroke Scale score, large vessel occlusions, and intravenous thrombolysis, as appropriate for each outcome. RESULTS: We included 3919 patients (median age, 74 [interquartile range (IQR), 63–82], 58% male, median National Institutes of Health Stroke Scale score 6 [IQR, 3–12]). Cardiac CT detected a thrombus in 243 (6.2%) patients. Among 1323 patients that underwent both cardiac CT and transthoracic echocardiography, cardiac CT had a higher yield than transthoracic echocardiography (odds ratio, 7.4 [95% CI, 4.0–15.1]; P <0.001). Median additional scan time was 6 minutes (IQR, 5–7) for ECG-gated and 13 seconds (IQR, 12–61) for non–ECG-gated cardiac CT. Median additional radiation dose was 2.9 mSv (IQR, 1.6–4.1). Patients with thrombi had higher 90-day mortality (33% versus 15%, adjusted odds ratio, 1.6 [95% CI, 1.1–2.3]) and worse modified Rankin Scale scores (median modified Rankin Scale score 3 versus 2, adjusted odds ratio, 1.6 [95% CI, 1.2–2.0]), but similar recurrent stroke rates (5% versus 4%, adjusted odds ratio, 1.4 [95% CI, 0.7–2.5]). CONCLUSIONS: Implementing cardiac CT into the acute stroke imaging protocol is feasible, detects thrombi in ≈6% of patients, and has a higher yield than transthoracic echocardiography. Cardiac thrombi were associated with higher mortality, but not higher stroke recurrence. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT07165093.
In situ impedance analysis device for clot characterization in large vessel occlusion acute ischemic stroke, a first-in-human study
Journal of NeuroInterventional Surgery | May 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: jnis-2025-024772
Background Large vessel occlusion (LVO) stroke is associated with a high risk of permanent disability. There are no reliable tools providing periprocedural information on clot characteristics, such as composition and length, that may impact first pass effect, which has been shown to improve functional outcomes. In the first study of a novel technology, we evaluated whether the Clotild Smart Guidewire System (Clotild), an impedance-based device, can provide in situ information on clot characteristics during a mechanical thrombectomy procedure. Methods This is the first-in-human, international, multicentric, single-arm trial involving LVO stroke patients. Of 45 enrolled subjects, 41 constituted the safety population; 39 was the per protocol population, of which 26 subjects with complete impedance data comprised the performance population. The latter was divided into development (11 subjects) and validation (15 subjects) populations for prediction model development and assessment. The safety endpoint assessed Clotild-related intracranial vessel perforation/dissection. Performance endpoints evaluated Clotild’s ability to perform classification of impedance measurements distinguishing substantial versus negligible local content in red blood cells (RBCs) and platelets, to detect the arterial wall and the distal end of the clot. Results The safety endpoint was met in all subjects. Performance analysis comparing the agreement between Clotild’s output and impedance experts’ readings showed an area under the receiver operating characteristic curve (AUC) of 0.97 (95% CI 0.93 to 0.99) for RBC, and 0.94 (95% CI 0.89 to 0.98) for platelet clot composition. Regarding detection, Clotild’s performance showed an AUC of 0.69 (95% CI 0.59 to 0.77) for the arterial wall, and 0.83 (95% CI 0.59 to 1.00) for the distal end of the clot. Conclusions Clotild was proven safe to acquire impedance data and to provide information on in situ clot characteristics in large vessel occlusions.