Back to Authors

Restrepo, Diego J.

0009-0007-8195-4189

A5126631361 | I4210125099

Mayo Clinic

Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.

Citations 14

Extended Trochanteric Osteotomy Combined with Medial Reduction Corticotomy to Correct Femoral Deformity at the Time of Revision Total Hip Arthroplasty

JBJS Open Access | September 19, 2025 | Volume: 10 | Issue: 3 | Pages: No page available

10.2106/jbjs.oa.25.00193 | PMID 40978000

Background: An extended trochanteric osteotomy (ETO) is commonly used to improve exposure and facilitate femoral component removal in revision total hip arthroplasty (THA). An additional medial corticotomy may be used in conjunction with an ETO to correct a femoral deformity, particularly varus remodeling in association with a failed femoral component. This study evaluated the outcomes of combining an ETO with a medial corticotomy in revision THA, with emphasis on implant fixation, femoral alignment, bone union, and clinical outcomes. Methods: Of the 612 ETOs performed between 2003 and 2013, 13 patients (9 men and 4 women) underwent ETO combined with a medial corticotomy to correct varus remodeling, representing 2% of all ETOs during that period. The average follow-up was 8 ± 3.5 years. The mean age at surgery was 67 ± 13.5 years. The mean body mass index was 32 ± 7.7 kg/m 2 . Radiographs were reviewed to measure preoperative and postoperative femoral deformity, time to consolidation, and femoral fixation. Clinical outcomes were evaluated using the Harris Hip Score (HHS). Results: All patients had preoperative varus femoral deformity (mean 16.3° ± 5.7°). The mean postoperative alignment was 4.3 ± 1.6° varus achieving an average correction of 12° (95% CI −15.7 to −8.3, p < 0.0001). Both the ETO and the medial corticotomy consolidated in 10 of 11 patients (91%) with available 1-year radiographs at a mean of 11 ± 7.7 months. The mean HHS improved significantly from 42 preoperatively to 82 at 5-year follow-up (p = 0.0002). Complications related to the ETO and corticotomy occurred in 4 patients (30%), including 1 intraoperative fracture, 1 postoperative greater trochanteric fracture, 1 nonunion of the medial corticotomy, and 1 postoperative wound-hematoma. All femoral components remained well fixed at final follow-up. Conclusion: The combination of ETO and medial corticotomy in revision THA effectively corrected femoral alignment in patients with a preoperative varus deformity and was associated with significant functional improvement at the final follow-up. Level of Evidence: Level IV . See Instructions for Authors for a complete description of levels of evidence.
The Broken Wing Sign: A New Clinical Test to Detect Gluteus Medius Pathology with and without Fatty Infiltration

Journal of Bone and Joint Surgery | September 12, 2025 | Volume: 107 | Issue: 21 | Pages: 2359-2364

10.2106/jbjs.25.00427 | PMID 40938961

Background: Gluteus medius tears and atrophy cause lateral hip pain, limp, and functional impairment. We developed the “broken wing sign,” a novel physical examination test for detecting gluteus medius tendon tears and muscle degeneration. This study evaluated its diagnostic accuracy and clinical utility against magnetic resonance imaging (MRI) and intraoperative findings. Methods: We prospectively examined 59 patients (75 hips; mean age, 69.5 ± 10.8 years; 48 women) with suspected hip abductor insufficiency. The broken wing sign was tested with patients prone, the knee flexed at 90°, and the hip actively extended. A positive sign involved ≥10° of compensatory external hip rotation, visible as an inward drift of the foot, indicating gluteus medius (and resulting internal rotation) weakness. MRI served as the reference standard for classifying gluteus medius integrity as no tear, partial, full-thickness, or massive. Fatty infiltration was graded (Goutallier grades 0 to 4), quantified, and analyzed for a correlation with the examination findings. Diagnostic accuracy metrics were calculated. Results: The broken wing sign demonstrated high accuracy (sensitivity, 81.8%; specificity, 80.0%; positive predictive value [PPV], 91.8%; negative predictive value, 61.5%; diagnostic odds ratio, 17.8). An external rotation threshold of ≥30° yielded 100% specificity and 100% PPV for a tear. The sign detected acute tears with no or minimal fatty infiltration (100% sensitivity for massive tears). The degree of the external rotation angle was strongly correlated with muscle atrophy with fatty infiltration, showing 88.0% sensitivity for Goutallier grade ≥3 and 100% sensitivity for grade 4. Conclusions: The broken wing sign is clinically useful for diagnosing gluteus medius tendon tears and muscle atrophy, particularly massive tears and advanced fatty degeneration. It effectively guides MRI utilization and surgical planning, serving as a valuable initial diagnostic tool in the clinical setting. Level of Evidence: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.
In Young Patients Undergoing Total Hip Arthroplasty, Is There a Correlation Between Activity Level and Wear of Highly Cross-Linked Polyethylene?

JBJS Open Access | May 14, 2025 | Volume: 10 | Issue: 2 | Pages: No page available

10.2106/jbjs.oa.24.00242 | PMID 40371259

Background: Total hip arthroplasty (THA) effectively restores mobility, reduces pain, and enhances the quality of life of patients of all ages. Despite its benefits, concerns regarding the long-term effects of high-impact activities and sports on implant longevity require further study. This study investigated the effect of activity level on long-term radiographic wear of highly cross-linked polyethylene (HXLPE) in young patients undergoing THA. Methods: Between 1999 and 2008, 785 patients (909 hips) aged ≤50 underwent primary THA using first-generation HXLPE liners from 4 different vendors with either metal or ceramic heads. Functional activity and participation questionnaires, including the Hip Injury and Osteoarthritis Outcome Score (HOOS Jr), University of California Los Angeles (UCLA) activity scale, and High-Activity Arthroplasty Score (HAAS), were surveyed in 2018 to 2019. The response rate was 44%. Radiographic linear wear rates were measured using the ROMAN software in patients who had completed questionnaires and had radiographs taken at least 10 years apart, leaving a final cohort of 249 patients (284 hips). Multivariate analyses were performed to determine the relationship between HXLPE wear rates and activity scores. Results: At the time of the survey, approximately 10% of the patients performed high-impact activities not-recommended by consensus guidelines. The HXLPE linear wear rate was 0.036 mm/year (SD: 0.026). Patients with higher activity levels, as measured on the continuous UCLA/HAAS activity scale, did not exhibit increased wear (β = -0.0009; p = 0.31). Stair climbing was correlated with increased wear rates (β = 0.0066; p = 0.004), whereas walking (β = 0.0005; p = 0.66) and running (β = 0.0017; p = 0.30) were not significantly correlated. Patients performing nonrecommended activities did not show increased wear rates compared with those performing recommended activities (β = 0.0063; p = 0.19). Conclusions: Linear wear rates of first-generation HXLPE were not related to functional activity or participation in high-impact activities. Future research should include longitudinal assessments of activity levels and data on other potential complications related to high-impact sports to provide robust evidence regarding recommended activity level postoperatively. Level of Evidence: Level III , Retrospective Comparative Study. See Instructions for Authors for a complete description of levels of evidence.
The effect of cemented femoral component design and prophylactic wire placement against early periprosthetic femoral fracture in primary total hip arthroplasty

The Bone & Joint Journal | May 1, 2025 | Volume: 107-B | Issue: 5 Supple A | Pages: 32-37

10.1302/0301-620x.107b5.bjj-2024-1116.r1 | PMID 40306725

AimsPrevious studies have highlighted differences in the risk of periprosthetic fractures (PPFs) in patients undergoing total hip arthroplasty with either a cemented taper slip (TS) stem or a composite beam (CB) stem. This biomechanical study explored the occurrence of PPF around these stems, and the protective effect of adding a 16-gauge prophylactic calcar or diaphyseal wire to the TS stems to increase the resistance to torque as a potential way to prevent these fractures.MethodsA total of 21 TS stems (eight alone, six with calcar wiring, and seven with diaphyseal wiring placed 2 cm distal to the lesser trochanter) and seven CB stems were cemented into standard sawbones. The peak torque at failure was measured using a servohydraulic test machine, and the fracture location was recorded. An a priori power analysis determined that seven specimens per group were needed to detect a 30 Nm difference with 90% power, assuming a 14.8 Nm SD in peak torque between groups. Comparisons were performed using paired t-tests.ResultsCB stems exhibited a significantly higher mean peak torque at failure (205.3 Nm (SD 26.9)) than TS stems (159.5 Nm (SD 17.4); p = 0.012), calcar-wired TS (148.2 Nm (SD 38.6); p = 0.031), and diaphyseal-wired TS (164.9 Nm (SD 21.5); p = 0.027). This study did not demonstrate that wired-TS stems had a higher peak torque at failure than non-wired TS stems. Additionally, calcar wiring was not found to be stronger than diaphyseal wiring (p = 0.400). Four CB fractures occurred distal to the stem, whereas all TS fractures occurred at the mid-stem, simulating a Vancouver type B fracture. Interestingly, adding the diaphyseal wire shifted the fracture location more distally in four of the seven stems (p = 0.070).ConclusionIn this model, CB stems had greater resistance to torque than TS stems, which may explain the lower risk of PPF. Adding calcar or diaphyseal wires to the TS stems resulted in no significant change in peak torque to fracture. CB cemented stems should be considered in patients at high risk of PPF.Cite this article: Bone Joint J 2025;107-B(5 Supple A):32–37.