Background— The use of transcatheter aortic valve replacement (TAVR) to treat aortic stenosis in the United States is growing, yet little is known about the variation in procedural outcomes in community practice. We developed a TAVR in-hospital mortality risk model and used it to quantify variation in mortality rates across United States (US) TAVR centers. Methods and Results— We analyzed data from 22 248 TAVR procedures performed at 318 sites participating in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry (November 2011 to October 2014). A Bayesian hierarchical model was developed to estimate hospital-specific risk-adjusted mortality rates adjusting for 40 patient baseline factors. A total of 1130 in-hospital deaths (5.1%) were observed. Reliability-adjusted risk-adjusted mortality rate estimates ranged from 3.4% to 7.7% with an interquartile range of 4.8% to 5.4%. A patient’s predicted odds of dying was 80% higher if treated by a hospital 1 standard deviation above the mean compared with a hospital 1 standard deviation below the mean (odds ratio =1.8; 95% credible interval, 1.4%–2.2%). Conclusions— Risk modeling of TAVR in-hospital mortality revealed variation in risk-adjusted mortality rates during the US early commercial experience. Transcatheter Valve Therapy Registry analyses using this model will support research, feedback reporting, and the identification of factors associated with quality.
One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
Development and Validation of a Risk Prediction Model for In-Hospital Mortality After Transcatheter Aortic Valve Replacement
Objective Pulmonary hypertension (PH) is associated with increased mortality after surgical or transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS), and when the pulmonary artery pressure is particularly elevated, there may be questions about the clinical benefit of TAVR. We aimed to identify clinical and haemodynamic factors associated with increased mortality after TAVR among those with moderate/severe PH. Methods Among patients with symptomatic AS at high or prohibitive surgical risk receiving TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) I randomised trial or registry, 2180 patients with an invasive measurement of mean pulmonary artery pressure (mPAP) recorded were included, and moderate/severe PH was defined as an mPAP ≥35 mm Hg. Results Increasing severity of PH was associated with progressively worse 1-year all-cause mortality: none (n=785, 18.6%), mild (n=838, 22.7%) and moderate/severe (n=557, 25.0%) (p=0.01). The increased hazard of mortality associated with moderate/severe PH was observed in females, but not males (interaction p=0.03). In adjusted analyses, females with moderate/severe PH had an increased hazard of death at 1 year compared with females without PH (adjusted HR 2.14, 95% CI 1.44 to 3.18), whereas those with mild PH did not. Among males, there was no increased hazard of death associated with any severity of PH. In a multivariable Cox model of patients with moderate/severe PH, oxygen-dependent lung disease, inability to perform a 6 min walk, impaired renal function and lower aortic valve mean gradient were independently associated with increased 1-year mortality (p<0.05 for all), whereas several haemodynamic indices were not. A risk score, including these factors, was able to identify patients with a 15% vs 59% 1-year mortality. Conclusions The relationship between moderate/severe PH and increased mortality after TAVR is altered by sex, and clinical factors appear to be more influential in stratifying risk than haemodynamic indices. These findings may have implications for the evaluation of and treatment decisions for patients referred for TAVR with significant PH. Trial registration NCT00530894.
Propensity-Matched Comparisons of Clinical Outcomes After Transapical or Transfemoral Transcatheter Aortic Valve Replacement
Background— The higher risk of adverse outcomes after transapical (TA) versus transfemoral (TF) transcatheter aortic valve replacement (TAVR) could be attributable to TA-TAVR being an open surgical procedure or to clinical differences between TA- and TF-TAVR patients. We compared outcomes after neutralizing patient differences using propensity score matching. Methods and Results— From April 2007 to February 2012, 1100 Placement of Aortic Transcatheter Valves (PARTNER)-I patients underwent TA-TAVR and 1521 underwent TF-TAVR with Edwards SAPIEN balloon-expandable bioprostheses. Propensity matching based on 111 preprocedural variables, exclusive of femoral access morphology, identified 501 well-matched patient pairs (46% of possible matches), 95% of whom had peripheral arterial disease. Matched TA-TAVR patients experienced more adverse procedural events, longer length of stay (5 versus 8 days; P <0.0001), and slower recovery (New York Heart Association class I, 31% versus 38% at 30 days, equalizing by 6 months at 51% versus 47%); stroke risk was similar (3.4% versus 3.3% at 30 days and 6.0% versus 6.7% at 3 years); mortality was elevated for the first 6 postprocedural months (19% versus 12%; P =0.01); but aortic regurgitation was less (34% versus 52% mild and 8.9% versus 12% moderate to severe at discharge, P =0.001; 36% versus 50% mild and 10% versus 15% moderate to severe at 6 months, P <0.0001). Conclusions— The likelihood of adverse periprocedural events and prolonged recovery is greater after TA-TAVR than TF-TAVR in vasculopathic patients after accounting for differences in cardiovascular risk factors, although stroke risk is equivalent and aortic regurgitation is less. As smaller delivery systems permit TF-TAVR in many of these patients, we recommend a TF-first access strategy for TAVR when anatomically feasible. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.
Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial Fibrillation
Background— In patients with severe aortic stenosis, transcatheter aortic valve replacement (TAVR) improves survival when compared with nonsurgical therapy but with higher in-hospital and lifetime costs. Complications associated with TAVR may decrease with greater experience and improved devices, thereby reducing the overall cost of the procedure. Therefore, we sought to estimate the effect of periprocedural complications on in-hospital costs and length of stay of TAVR. Methods and Results— Using detailed cost data from 406 TAVR patients enrolled in the Placement of Aortic Transcatheter Valve (PARTNER) I trial, we developed multivariable models to estimate the incremental cost and length of stay associated with specific periprocedural complications. Attributable costs and length of stay for each complication were calculated by multiplying the independent cost of each event by its frequency in the treatment group. Mean cost for the initial hospitalization was $79 619±40 570 ($50 891 excluding the valve); 49% of patients had ≥1 complication. Seven complications were independently associated with increased hospital costs, with major bleeding, arrhythmia, and death accounting for the largest attributable cost per patient. Renal failure and the need for repeat TAVR, although less frequent, were also associated with substantial incremental and attributable costs. Overall, complications accounted for $12 475 per patient in initial hospital costs and 2.4 days of hospitalization. Conclusions— In the PARTNER trial, periprocedural complications were frequent, costly, and accounted for ≈25% of non-implant–related hospital costs. Avoidance of complications should improve the cost-effectiveness of TAVR for inoperable and high-risk patients, but reductions in the cost of uncomplicated TAVR will also be necessary for optimal efficiency. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.
Impact of Aortic Annulus Size on Valve Hemodynamics and Clinical Outcomes After Transcatheter and Surgical Aortic Valve Replacement
Background— The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. Methods and Results— Patients included the randomized controlled trial (n=574) and nonrandomized continued access (n=1358) cohorts were divided in tertiles according to aortic annulus diameter (small aortic annulus tertile, medium aortic annulus tertile, and large aortic annulus tertile [LAA], respectively) as measured by transthoracic echocardiography. Severe prosthesis–patient mismatch was defined as an effective aortic orifice area of <0.65 cm 2 /m 2 . In the randomized controlled trial cohort, patients in the small aortic annulus tertile who underwent transcatheter aortic valve replacement had a lower incidence of severe prosthesis–patient mismatch (19.7% versus 37.5%; P =0.03) and only a trend toward a higher incidence of moderate-to-severe paravalvular leaks compared with surgical aortic valve replacement (5.7% versus 0%; P =0.06). In the LAA tertile, there were no differences in the rate of prosthesis–patient mismatch between groups, and a significant increase in moderate-to-severe paravalvular leaks was associated with transcatheter aortic valve replacement (9% versus 0%; P =0.01). There were no differences in mortality between transcatheter aortic valve replacement and surgical aortic valve replacement. In the nonrandomized continued access cohort, there were no differences in prosthesis–patient mismatch between the small aortic annulus and LAA tertiles, but a higher rate of moderate-to-severe paravalvular leaks was observed in the LAA tertile (5.9% versus 11.5%; P =0.009). Patients in the LAA tertile had a higher mortality rate at 1-year follow-up ( P =0.02), and differences persisted in multivariable analysis ( P =0.048 for LAA versus medium aortic annulus tertile, P =0.035 for LAA versus small aortic annulus tertile). Conclusions— Aortic annulus size had a major impact on valve hemodynamics and clinical outcomes after transcatheter aortic valve replacement and surgical aortic valve replacement. This study highlights the importance of considering aortic annulus size in the evaluation of high-risk patients who are candidates for aortic valve replacement. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.
Hospital Percutaneous Coronary Intervention Appropriateness and In-Hospital Procedural Outcomes
Circulation: Cardiovascular Quality and Outcomes | May 11, 2012 | Volume: 5 | Issue: 3 | Pages: 290-297
Background— Measurement of hospital quality has traditionally focused on processes of care and postprocedure outcomes. Appropriateness measures for percutaneous coronary intervention (PCI) assess quality as it relates to patient selection and the decision to perform PCI. The association between patient selection for PCI and processes of care and postprocedural outcomes is unknown. Methods and Results— We included 203 531 patients undergoing nonacute (elective) PCI from 779 hospitals participating in the National Cardiovascular Data Registry (NCDR) CathPCI Registry between July 2009 and April 2011. We examined the association between a hospital's proportion of nonacute PCIs categorized as inappropriate by the 2009 Appropriate Use Criteria (AUC) for Coronary Revascularization and in-hospital mortality, bleeding complications, and use of optimal guideline-directed medical therapy at discharge (ie, aspirin, thienopyridines, and statins). When categorized as hospital tertiles, the range of inappropriate PCI was 0.0% to 8.1% in the lowest tertile, 8.1% to 15.2% in the middle tertile, and 15.2% to 58.6% in the highest tertile. Compared with lowest-tertile hospitals, mortality was not significantly different at middle-tertile (adjusted odds ratio [OR], 0.93; 95% confidence interval [CI], 0.73–1.19) or highest-tertile hospitals (OR, 1.12; 95% CI, 0.88–1.43; P =0.35 for differences between tertiles). Similarly, risk-adjusted bleeding did not vary significantly (middle-tertile OR, 1.13; 95% CI, 1.02–1.16; highest-tertile OR, 1.02; 95% CI, 0.91–1.16; P =0.07 for differences between tertiles) nor did use of optimal medical therapy at discharge (85.3% versus 85.7% versus 85.2%; P =0.58). Conclusions— In a national cohort of nonacute PCIs, a hospital's proportion of inappropriate PCIs was not associated with in-hospital mortality, bleeding, or medical therapy at discharge. This suggests PCI appropriateness measures aspects of hospital PCI quality that are independent of how well the procedure is performed. Therefore, PCI appropriateness and postprocedural outcomes are both important metrics to inform PCI quality.