Citations 79

Determinants of Health-Related Quality of Life as Assessed by the PAH-SYMPACT Questionnaire in Patients with Pulmonary Arterial Hypertension

B55. POT POURRI OF THE TOP CLINICAL STUDIES IN PULMONARY HYPERTENSION | July 7, 2020 | Volume: No volume available | Issue: No issue available | Pages: A3799-A3799

10.1164/ajrccm-conference.2020.201.1_meetingabstracts.a3799

Quality of Life as Assessed by the SYMPACT Questionnaire in Patients with Chronic Thromboembolic Pulmonary Hypertension

A54. WHAT'S NEW IN CTEPH?: CLINICAL STUDIES | July 7, 2020 | Volume: No volume available | Issue: No issue available | Pages: A2046-A2046

10.1164/ajrccm-conference.2020.201.1_meetingabstracts.a2046

Left ventricle assist device pulsatility index at the time of implantation is associated with follow-up pulmonary hemodynamics

The International Journal of Artificial Organs | January 27, 2020 | Volume: 43 | Issue: 7 | Pages: 452-460

10.1177/0391398819899403 | PMID 31984834

HeartMate II left ventricular assist device controllers provide data including pulsatility index, reflecting the relationship between pump function and hemodynamics. We propose that a higher pulsatility index at hospital discharge following implant may be associated with less vascular congestion and improved clinical outcomes. A retrospective analysis of 40 patients (age 59.2 ± 10.3 years) supported with the HeartMate II devices was conducted. Data revealed moderate Pearson correlations between pulsatility index at discharge and right atrial pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure, respectively, post-surgery (median of 377 days), demonstrating a stronger relationship when analyzed for the EPC controller (n = 28) only (r = −.57, p < .01; r = −.38, p < .05; r = −.59, p < .01; r = −.47, p = .01 and r = −.53, p < .01, respectively). The pulsatility index derived from the EPC controller was associated with the significant risk of re-hospitalization within 1 and 2 years after the implantation of left ventricular assist device; hazard ratio = 0.557 with 95% confidence interval (0.315–0.983), p = .04 and hazard ratio = .579 (0.341–0.984), p = .04. A higher pulsatility index at discharge was associated with greater volume unloading, lower pulmonary pressures, and lower risk of all-cause re-hospitalizations within 1 and 2 years post-surgery. As such, pump-derived data may provide additional value in predicting left ventricular assist device hemodynamics.
Predictors and Clinical Outcomes of Vasoplegia in Patients Bridged to Heart Transplantation With Continuous‐Flow Left Ventricular Assist Devices

Journal of the American Heart Association | November 8, 2019 | Volume: 8 | Issue: 22 | Pages: No page available

10.1161/jaha.119.013108 | PMID 31701791

Background The presence of a durable left ventricular assist device ( LVAD ) is associated with increased risk of vasoplegia in the early postoperative period following heart transplantation ( HT ). However, preoperative predictors of vasoplegia and its impact on survival after HT are unknown. We sought to examine predictors and outcomes of patients who develop vasoplegia after HT following bridging therapy with an LVAD . Methods and Results We identified 94 patients who underwent HT after bridging with continuous‐flow LVAD from 2008 to 2018 at a single institution. Vasoplegia was defined as persistent low vascular resistance requiring ≥2 intravenous vasopressors within 48 hours after HT for >24 hours to maintain mean arterial pressure >70 mm Hg. Overall, 44 patients (46.8%) developed vasoplegia after HT . Patients with and without vasoplegia had similar preoperative LVAD , echocardiographic, and hemodynamic parameters. Patients with vasoplegia were significantly older; had longer LVAD support, higher preoperative creatinine, longer cardiopulmonary bypass time, and higher Charlson comorbidity index; and more often underwent combined organ transplantation. In a multivariate logistic regression model, older age (odds ratio: 1.08 per year; P =0.010), longer LVAD support (odds ratio: 1.06 per month; P =0.007), higher creatinine (odds ratio: 3.9 per 1 mg/dL; P =0.039), and longer cardiopulmonary bypass time (odds ratio: 1.83 per hour; P =0.044) were independent predictors of vasoplegia. After mean follow‐up of 4.0 years after HT , vasoplegia was associated with increased risk of all‐cause mortality (hazard ratio: 5.20; 95% CI, 1.71–19.28; P =0.003). Conclusions Older age, longer LVAD support, impaired renal function, and prolonged intraoperative CPB time are independent predictors of vasoplegia in patients undergoing HT after LVAD bridging. Vasoplegia is associated with worse prognosis; therefore, detailed assessment of these predictors can be clinically important.
Exercise-induced hypoxemia predicts heart failure hospitalization and death in patients supported with left ventricular assist devices

The International Journal of Artificial Organs | October 19, 2019 | Volume: 43 | Issue: 3 | Pages: 165-172

10.1177/0391398819882435 | PMID 31630619

Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise–induced hypoxemia (O 2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4–57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO 2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6–322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.
Sequential Heart and Autologous Stem Cell Transplantation for AL Amyloidosis.

Blood | October 11, 2019 | Volume: 108 | Issue: 11 | Pages: 3092-3092

10.1182/blood.v108.11.3092.3092

Abstract Background: Patients with AL and congestive heart failure have a median survival of less than one year. Methods: Between 1994 and 2005, 11 patients underwent sequential heart transplant followed by autologous peripheral blood stem cell transplant (SCT) for treatment of AL. Patients had heart dominant AL with minimal/no other organ impairment and no evidence of multiple myeloma. Results: Patients ranged in age from 35 to 63 years (median 54). All had biopsy proven amyloidosis and monoclonal protein detectable in serum (73%) or urine (100%). Free light chain assay was available prior to SCT in 6 and was abnormal in all. All patients presented with NYHA Class III or IV heart failure. All but two patients had no other organ involved at the time of heart transplant. One patient had his heart transplant at another facility and had renal involvement at the time of heart transplant. One patient had peripheral nerve involvement documented prior to heart transplant. Five patients had progression of amyloid to involve other organs by the time of SCT. These included: renal (6), peripheral nerve (2), macroglossia (3), gastrointestinal (2). The median time from diagnosis to heart transplant was 3 months (range 1 to 5). The median time from heart transplant to SCT was 8 months, (range 3 to 24). Conditioning chemotherapy consisted of melphalan 200 mg /m2 (6 patients) or melphalan 140 mg/m2 (5 patients). Two patients died of complications before day +100, (TRM of 18%). Hematologic remissions were seen in 8 and organ responses in 3. Five were unable to be evaluated for organ response due to the heart transplant. Three died from progressive amyloidosis at 66, 56.7, and 55 months following SCT. The median survival is 56.7 months from SCT. Six are alive with a median follow-up of 24 months, range 9 to 90 months. Among the 6 surviving patients, one patient relapsed and one patient has failed to improve, but 4 patients are in continued remission. One patient developed secondary myelodysplastic syndrome. Conclusions: Heart transplant followed by SCT is feasible and offers durable remissions for carefully selected patients with cardiac AL. Figure Figure
Diastolic Pulmonary Gradient as a Predictor of Right Ventricular Failure After Left Ventricular Assist Device Implantation

Journal of the American Heart Association | August 14, 2019 | Volume: 8 | Issue: 16 | Pages: No page available

10.1161/jaha.119.012073 | PMID 31411097

Background Diastolic pulmonary gradient ( DPG ) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance ( PVR ) and transpulmonary gradient ( TPG ). The prognostic significance of DPG in patients requiring a left ventricular assist device ( LVAD ) remains unclear. We sought to investigate whether pre‐ LVAD DPG is a predictor of survival or right ventricular ( RV ) failure post‐ LVAD . Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all‐cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan–Meier analyses. After a mean follow‐up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [ HR ]: 3.30; P =0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR ( HR 1.85, P =0.13 for PVR ≥3 versus PVR <3) or TPG ( HR 1.47, P =0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk ( HR 1.16, P =0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR , but not TPG , was associated with higher mortality risk ( HR 1.55; P =0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices

The International Journal of Artificial Organs | August 14, 2019 | Volume: 43 | Issue: 2 | Pages: 99-108

10.1177/0391398819868236 | PMID 31411101

Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m −2 ) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy

Journal of the American Heart Association | February 13, 2019 | Volume: 8 | Issue: 4 | Pages: No page available

10.1161/jaha.118.010232 | PMID 30755070

Background Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cf LVADs ). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. Methods and Results To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cf LVAD was developed. Patients implanted with cf LVAD s underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient ( TAG ) was established. Thirty eight patients with cf LVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG . A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. Conclusions Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cf LVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.
Pulmonary Function Assessment Post-Left Ventricular Assist Device Implantation

ESC Heart Failure | October 12, 2018 | Volume: 6 | Issue: 1 | Pages: 53-61

10.1002/ehf2.12348 | PMID 30311748

Abstract Aim The lungs—and particularly the alveolar-capillary membrane—may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function. Methods and results We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)] and diffusing capacity of the lung for carbon monoxide (DLCO) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (−23%) since pre-implantation (P &lt; 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P &lt; 0.01) and ΔDLCO to ΔRAP (r = 0.39, P &lt; 0.05). We observed other reductions in FEV1, FVC, and FEV1/FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1/FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28–0.98); P = 0.03]. Conclusions Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.