Abstract Background Tau‐PET tracers are essential for visualizing pathology in Alzheimer's (AD). High detectability to tau is crucial for early detection and monitoring of tau deposition. This study compares the noise to dynamic range ratio (NRR) of [ 18 F]FTP, [ 18 F]MK6240, [ 18 F]PI2620, and [ 18 F]RO948, cross‐sectionally and longitudinally. Methods 460 individuals from the HEAD study (23 cognitively unimpaired (CU) young, 249 CU old and 188 cognitively impaired) underwent [ 18 F]FTP and [ 18 F]MK6240 tau‐PET scans; 94 additionally received [ 18 F]PI2620 and [ 18 F]RO948. A subset of 28 individuals (15 CU and 13 CI) underwent [ 18 F]FTP and [ 18 F]MK6240 follow‐up scans (1.5 ± 0.1 years later). Annual change was measured as [(followup‐baseline)/time between scans]. Noise was calculated as the standard deviation (SD) of CU Aβ‐ participants aged ≤65 (SD CUAβ‐≤65 ). The dynamic range was calculated as the SD across all subjects (SD range ). A lower the NRR (=SD CUAβ‐≤65 /SD range ) indicates more detectability. Analyses were performed at both region‐of‐interest and voxel‐wise levels. Results Across the whole cohort, [ 18 F]MK6240 exhibited lower NRR than [ 18 F]FTP in all regions. Voxel‐wise, differences were most pronounced in the frontal medial temporal regions (Figure 1). Within the four‐tracers subset, [ 18 F]PI2620 and [ 18 F]FTP showed the highest NRR in Braak II, followed by [ 18 F]RO948 and [ 18 F]MK6240. In Braak IV‐VI, [ 18 F]MK6240 consistently demonstrated the lowest values, followed by [ 18 F]PI2620, [ 18 F]FTP and [ 18 F]RO948. Similarly, in metatemporal‐ROI and Braak III, [ 18 F]MK6240 remained the lowest, however followed by [ 18 F]FTP, [ 18 F]PI2620 and [ 18 F]RO948 (Figure 2). Lower [ 18 F]MK6240 NRR was due to larger SD range , while [ 18 F]FTP's lower values stemmed from smaller SD CUAβ‐≤65 . Conversely, high [ 18 F]PI2620 and [ 18 F]RO948 values are driven by larger SD CUAβ‐≤65 . Longitudinal analyses further confirmed that [ 18 F]MK6240 exhibited the lowest NRR across the entire brain, including AD‐related regions, with voxel‐wise differences mainly in the temporal and parietal lobes. Conclusion Tau‐PET tracers exhibit significant variability in detectability. [ 18 F]MK6240 consistently demonstrated lower NRR, implying better detectability across all regions, cross‐sectionally and longitudinally. Despite differences in NRR, [ 18 F]FTP, [ 18 F]RO948 and [ 18 F]PI2620 followed similar pattern. These results provide insights into the differential tracer detectability, helping guide their optimal use in detecting and tracking tau pathology. Ongoing follow‐up scans will further clarify longitudinal tracer detectability and its implications for tau progression in AD.
Every Centiloid, from Everywhere, All at Once
Alzheimer's & Dementia | January 9, 2026 | Volume: 21 | Issue: S2 | Pages: No page available
Abstract Background Ten years after the original publication, the Centiloid framework is now broadly used to harmonize amyloid‐PET quantification, facilitate data sharing and comparison across cohorts, and even assist visual interpretation in clinical settings. We evaluated the global implementation of Centiloids by comparing their distribution and corresponding positivity thresholds across cohorts. Methods We gathered data from publicly available cohorts and reached out to investigators across the world to collect cross‐sectional Centiloids, demographic and clinical information, and visual read data. Gaussian mixture models (GMM, k=2) were fitted to Centiloid values for each cohort and cutoffs were calculated as mean + 2SD of the lower Gaussian. When visual reads were available, we determined Centiloid cutoffs that maximized correspondence with visual reads (Cohen's kappa). Data was combined across cohorts using random effects meta‐analyses. Results As of January 2025, we included 37 cohorts ( n = 41,678 participants) with heterogeneous pipelines, radiotracers, and clinical and demographic characteristics (Table‐1). The low Gaussian peaks ranged from ‐9 to 10CL; the meta‐analysis identified a common peak at 1CL. The second peaks were more heterogeneous (range=38‐102CL; meta‐analysis outcome=64CL). Across cohorts, the proportion of cognitively unimpaired versus impaired participants impacted the position of both peaks, with better separation in cohorts enriched in impaired individuals (Figure 1C). The meta‐analysis indicated a GMM‐based cutoff of 19CL (95%CI: 16‐21CL, Figure 1B); subgroup analyses showed no evidence of significant effect between single versus multicenter settings (17 versus 20CL, p = 0.30), MRI‐based or PET‐only processing (18 versus 19CL, p = 0.88), and no evidence of difference across radiotracers (Flutemetamol: 16CL; PIB: 17CL, Flutafuranol: 18CL, Florbetaben: 19CL, Florbetapir: 20CL, p = 0.78). In a subset of 29,496 participants with visual reads available, binary visual reads corresponded well to Centiloids (common kappa=0.86, Figure 2A). The visual read‐based cutoff of 24CL (95%CI: 21‐27CL, Figure 2B) maximized correspondence between visual read and quantification and was slightly higher than the GMM‐based cutoff. All meta‐analysis models showed high non‐random heterogeneity (I 2 >80%) across studies, suggesting non‐random differences in peaks and cutoffs. Conclusions Meta‐analysis‐based cutoffs align well with thresholds from the existing literature. High heterogeneity among studies underscores the need to investigate contributing factors, raising concerns about applying common cutoffs.