Citations 11

Standard clinical and stress electrocardiogram variables to exclude left main and left main-equivalent disease: the MASTER study

European Heart Journal | May 30, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/eurheartj/ehag464 | PMID 42489631

Abstract Background and Aims A simple diagnostic method able to reliably exclude left main (LM) coronary artery disease (CAD) or LMCAD-equivalent would expand implementation of an initial non-invasive strategy in patients with chronic coronary syndrome (CCS). This study assessed the diagnostic utility of an approach using clinical and ECG stress testing (EST) variables in excluding LMCAD/LMCAD-equivalent in CCS patients. Methods In a multicentre case-control study, CCS patients undergoing invasive coronary angiography (CAG) after a maximal EST were evaluated. Cases were patients with angiographic ≥ 50% LM stenosis or ≥70% stenosis of both proximal left anterior descending and proximal circumflex arteries, matched with similar patients without them (controls) in a 1:3 ratio. A risk model developed through logistic regression was internally and externally validated. Results Three hundred and thirty-five cases were matched with 797 controls. The model area under the curve (AUC) was .78. Assuming LMCAD prevalence of 5% and a misclassification cost ratio of 1:100 (ratio of cost of performing CAG in a control to cost of not performing CAG in a case), negative predictive value was 98.2%. Thus, CAG could be safely avoided in 41% of patients, missing one LMCAD/LMCAD-equivalent diagnosis for every 58 CAGs safely spared in patients without them. Conclusions Among CCS patients, LMCAD/LMCAD-equivalent can be excluded with high negative predictive value through a model based on clinical and EST parameters, allowing initial non-invasive management of most patients able to exercise. This approach is potentially useful particularly in communities where access to computed tomography coronary angiography is limited.
Incremental Prognostic Power of Coronary Flow Reserve and Artificial Intelligence–Enabled ECG–Derived Filling Pressure in Angina With Nonobstructive Coronary Arteries

Journal of the American Heart Association | May 6, 2026 | Volume: 15 | Issue: 10 | Pages: No page available

10.1161/jaha.125.047946 | PMID 42089212

Background Coronary flow reserve reflects microvascular function, whereas filling pressure indicates myocardial hemodynamic burden. In angina with nonobstructive coronary arteries, abnormalities in either could contribute to a supply–demand mismatch; however, their combined prognostic significance remains unclear. Methods Patients with angina with nonobstructive coronary arteries who underwent invasive coronary reactivity tests were studied retrospectively. Coronary microvascular dysfunction (CMD) was coronary flow reserve <2.5. An artificial intelligence–enabled ECG marker of elevated filling pressure (AIEFP) was applied as a scalable prognostic marker of myocardial hemodynamic stress. Associations with major adverse cardiovascular events were evaluated using Cox regression and propensity score overlap weighting. Results Among 1957 patients with angina with nonobstructive coronary arteries (median age, 51.8 years; 67.2% women), CMD+ was identified in 26.4% and AIEFP+ in 6.6%. Over 8 years, 204 patients (10.4%) experienced major adverse cardiovascular events. In nested models, both CMD (hazard ratio [HR]=1.42 [95% CI=1.13–1.78]; P =0.002) and AIEFP (HR=2.28 [95% CI=1.67–3.11]; P <0.001) remained associated with major adverse cardiovascular events after adjustment. Adding AIEFP to the base model improved model fitness (Δχ 2 =23.65, P <0.001; ΔAkaike Information Criterion=−21.7) and modestly improved discrimination (ΔHarrell concordance index=0.02, P =0.02). In a 4‐group model, adjusted risks increased in a graded manner. Overlap‐weighted analysis after covariate balance demonstrated distinct temporal risk trajectories: CMD+/AIEFP+ had the highest 1‐year risk (12.7%), and AIEFP+ had the highest cumulative 8‐year risk (57% in CMD− and 51.8% in CMD+). Conclusions CMD and AIEFP provide complementary prognostic information, with AIEFP remaining significantly associated with outcomes after multivariable adjustment. A dual‐axis framework integrating myocardial hemodynamic stress (AIEFP) and microvascular function (coronary flow reserve) may enhance risk stratification and enable identification of clinically distinct angina with nonobstructive coronary arteries phenotypes with divergent trajectories.
Inadequate Preventive Dental Care Is Associated With Higher Cardiovascular Risk Identified by ECG‐Based Artificial Intelligence Algorithms

Journal of the American Heart Association | February 20, 2026 | Volume: 15 | Issue: 5 | Pages: No page available

10.1161/jaha.125.044906 | PMID 41717947

Background Inadequate preventive dental care may contribute to inflammatory conditions such as periodontitis, increasing cardiovascular disease risk. Artificial intelligence–enabled electrocardiography (AI‐ECG) algorithms accurately estimate cardiovascular disease risk. We investigated the association between inadequate preventive dental care and the AI‐ECG–estimated risk of atrial fibrillation, aortic stenosis, low ejection fraction, cardiac amyloid, cardiovascular aging, and all‐cause mortality. Methods We retrospectively analyzed 266 637 Mayo Clinic patients (2018–2024) who completed a Social Determinants of Health Survey and had an ECG performed within 1 year of survey completion. AI‐ECG algorithms generated continuous risk scores (0 or 1) for atrial fibrillation, aortic stenosis, low ejection fraction, and amyloid. Cardiac aging was assessed by delta age, calculated as AI‐ECG–estimated physiological age minus the chronological age. Associations with preventive dental care were analyzed using logistic regression. Cox regression evaluated dental care predictiveness on all‐cause mortality. Results Among 266 637 individuals (mean age, 59.5±16.4 years; 51.1% women), 49 918 (18.7%) reported inadequate preventive dental care. These individuals had higher delta age and increased AI‐ECG–predicted risks of atrial fibrillation, aortic stenosis, amyloid, and reduced ejection fraction (all P <0.001). In multivariable logistic regression models including all AI‐ECG scores, inadequate preventive dental care was associated with higher probabilities of low ejection fraction (odds ratio [OR], 1.80 [95% CI, 1.69–1.91]), atrial fibrillation (OR, 1.10 [95% CI, 1.04–1.17]), aortic stenosis (OR, 1.90 [95% CI, 1.64–2.20]), amyloid (OR, 1.18 [95% CI, 1.12–1.25]), and higher delta age (OR, 1.03 [95% CI, 1.02–1.03]) (all P <0.001). Inadequate preventive dental care predicted all‐cause mortality after adjusting for demographics, risk factors, and AI‐ECG algorithms (HR, 1.45 [95% CI, 1.38–1.53], P <0.001). Conclusions Inadequate preventive dental care is associated with subclinical cardiovascular disease. AI‐ECG algorithms may facilitate cardiovascular risk stratification among individuals with limited preventive dental care access.
Phenotypic Clustering of Systolic Blood Pressure–Heart Rate Synchronization Using Ambulatory Monitoring

No container title available | January 22, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.01.16.26343820

Abstract Background Interindividual variation in systolic blood pressure (SBP)–heart rate (HR) coupling reflects differences in autonomic and vascular regulation. The primary objective of this study was to determine whether SBP–HR synchronization identifies distinct hemodynamic phenotypes associated with demographic characteristics and blood pressure (BP) profiles in hypertensive and normotensive individuals. Methods We conducted a cross-sectional cohort analysis of 1,122 adults who underwent continuous 24-hour ambulatory monitoring of SBP, diastolic blood pressure (DBP), and HR in an outpatient clinical setting. Participants were classified as hypertensive or normotensive using guideline-based criteria. The primary exposure variable was SBP–HR synchronization, quantified using zero-lag cross-correlation coefficients. The primary outcomes were demographic characteristics (age, sex, stature) and BP phenotypes, including isolated systolic hypertension (ISH). Unsupervised partitioning around medoids clustering was used to identify synchronization-based phenotypes. Group comparisons were performed using Welch’s ANOVA and χ² testing, with multivariable adjustment for age and sex where applicable. Results All 1,122 participants were included in the final analysis (mean age 60.7 years; 52% female). Three synchronization phenotypes were identified: low, moderate, and high. Compared with the low-synchronization phenotype, the high-synchronization phenotype was younger (55.2 ± 15.0 vs. 66.6 ± 13.9 years), taller (170.4 ± 9.4 vs. 167.4 ± 10.5 cm), more frequently male (56% vs. 38%), and had lower baseline SBP (131.8 ± 17.5 vs. 136.7 ± 24.2 mmHg). Overall hypertension prevalence did not differ across phenotypes; however, ISH was less frequent in the high-synchronization phenotype (15.7% vs. 23.4%). Cluster assignments were robust across sensitivity analyses. Conclusions SBP–HR synchronization identifies distinct hemodynamic phenotypes associated with age, sex, stature, and BP characteristics. Stronger synchronization reflects a physiological profile consistent with preserved autonomic–vascular integration and lower prevalence of isolated systolic hypertension, supporting its potential role in refined cardiovascular phenotyping.
Assessment of Clinical Significance of Molecular Streptococcus agalactiae Detection in Patients With Suspected Pneumonia

Open Forum Infectious Diseases | December 20, 2025 | Volume: 13 | Issue: 1 | Pages: No page available

10.1093/ofid/ofaf781 | PMID 41531502

Abstract Background Streptococcus agalactiae (group B Streptococcus [GBS]) may cause pneumonia or may colonize the respiratory tract, making its clinical significance uncertain when detected in respiratory specimens. This study aimed to assess whether clinicians interpreted GBS detected by the BIOFIRE Pneumonia Panel (BF-PP) as a pathogen implicated in pneumonia. Methods This retrospective cohort study included adult patients hospitalized with suspected pneumonia at Mayo Clinic, Rochester, between September 2020 and February 2025. Cases were independently classified into pathogen and nonpathogen groups by 2 infectious diseases (ID) specialists, with a third reviewer resolving disagreements. Clinical characteristics and outcomes of both groups were recorded. A subgroup analysis of patients who had an ID consultation was performed. Results A total of 109 cases were included. GBS was considered a pneumonia pathogen in 47.7% of cases and a nonpathogen in 52.3%. ID consultation was performed in 33.0% of cases, with GBS considered a pathogen in 30.6% of those. Common comorbid conditions included pulmonary, gastrointestinal, neurologic, and cardiovascular disease and obesity. Rates of endotracheal intubation were similar in the pathogen and nonpathogen groups (51.9% vs 50.9%, respectively), with the in-hospital mortality rate being numerically but not significantly higher in the former versus the latter (21.2% vs 14.0%; P = .33); findings were similar in the ID-assessed subgroup. In 76.1% of GBS detections, other microorganisms—most commonly Staphylococcus aureus—were codetected. Only 10.2% of BF-PP GBS-positive specimens were culture positive for GBS. Conclusions While GBS is not an uncommon pneumonia pathogen, the clinical significance of its detection by BF-PP is uncertain in many cases.
Reduced Circulating α‐Klotho Levels Are Associated With Elevated Mortality and Arterial Calcifications of Aorta and Iliac Arteries

Journal of the American Heart Association | November 17, 2025 | Volume: 14 | Issue: 22 | Pages: No page available

10.1161/jaha.125.043654 | PMID 41246814

Background α‐Klotho is a multifunctional protein implicated in vascular aging. Declining Klotho levels are associated with arterial stiffness, endothelial dysfunction, and vascular calcification. We investigated the associations between circulating klotho, aortoiliac calcification, endothelial progenitor cells, and 10‐year survival. Methods In this retrospective cohort, blinded clinicians scored calcification on computed tomography (0–10 scale: aorta 6 points, iliac 4 points). Plasma klotho was measured by ELISA; endothelial progenitor cell subsets were quantified via flow cytometry. Mortality data were obtained from the Minnesota Death Registry. Results This study included 148 participants (mean age 72.4±9.6 years; 41% female). Median calcification score was 3 (interquartile range, 1–5). Patients with low calcification had higher Klotho levels (669 [567–841] versus 556 [457–678] pg/mL; P <0.01), with Klotho inversely correlated with calcification (r=−0.315, P <0.01). Stratified by calcification location and severity, the highest Klotho levels were seen in patients without aortic or iliac calcification ( P =0.015). Over 10 years, low Klotho was independently associated with higher mortality (hazard ratio [HR], 3.056 [95% CI 1.288–7.878]; P =0.014). Klotho inversely correlated with mature osteocalcin‐positive EPCs; B=−0.16 (95% CI, −0.29 to −0.02; P =0.027). Immunohistochemistry and immunofluorescence confirmed endothelial Klotho expression in internal mammary artery. Conclusions Lower circulating Klotho levels are associated with increased aortoiliac calcification and higher 10‐year mortality, supporting a role for Klotho in vascular aging.
Abstract 4358325: Performance of a cuffless photoplethysmography-based device for continuous monitoring of blood pressure

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4358325

Introduction: Blood pressure (BP) is a complex physiological marker. Cuffless devices, often based on photoplethysmography (PPG), enable frequent or continuous BP monitoring without arterial occlusion, enhancing comfort and usability in both inpatient and outpatient settings. Various devices have received regulatory clearance, but they are not yet included in clinical guidelines due to evolving validation standards. Aim: To evaluate accuracy of the Biobeat WP613 device for continuous BP monitoring using invasive intra-arterial pressure (IAP) monitoring in ICCU patients. Methods: This prospective, single-center study enrolled adults undergoing cardiac surgery at Chaim Sheba Medical Center (June 2020–January 2023) who had radial artery catheters for standard BP monitoring. Severe shock patients were excluded. Demographics and Fitzpatrick skin tone were recorded. ClinicalTrials.gov NCT04071015. Post-op, patients were simultaneously monitored with the standard IAP system and the Biobeat device. Continuous BP and HR were collected for up to five days. Data analyzed post hoc. Tested device The WP613 (Biobeat, Israel) is FDA-cleared, chest-worn, PPG-based device that uses multi-wavelength light and a sensor to monitor vital signs. It wirelessly transmits data to a cloud based algorithms to measure BP, cardiac output, stroke volume, and more. It also records a single-lead ECG and has a 5-day battery life. Results: A total of 96 patients were enrolled, with 88 included in the final BP analysis after excluding 8 due to technical issues. Of those, 80 received inotropic support. The average age was 63.2±12.2 years, with 33% female. Monitoring lasted an average of 25.6±17.2 hours, yielding over 78000 readings for each BP parameter and over 92000 HR readings (Fig 1) . Patients represented the full range of skin tones, classified using the Fitzpatrick scale I–VI. The Biobeat device showed excellent correlation with IAP monitoring: r=0.959 for SBP, 0.973 DBP, and 0.962 HR. Bland-Altman showed minimal bias (e.g., 0.1±4.8 for SBP) (Fig 2) . Correlation remained strong across BP ranges and skin tones. Heatmaps and representative cases confirmed close tracking between Biobeat and IAP (Fig 3) . Conclusion: The tested cuffless device (Biobeat) offers a high level of accuracy and agreement for BP and HR compared to data obtained by IAP monitoring in post-cardiac surgery patients. Further studies are needed to validate these findings in various populations and clinical settings.
Abstract 4357221: Monocyte to Lymphocytes Ratio as a Superior Predictor of Major Cardiovascular Events compared to hs-CRP in Patients with Angina and Nonobstructive Coronary Artery Disease

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4357221

Background: An increasing recognition of angina and nonobstructive coronary artery disease (ANOCA) underscores the importance of this patient group. While inflammation is a well-established key driver in the initiation and progression of atherosclerosis, its role in early stage is less clear. The current study was designed to assess the predictive value of monocyte-lymphocyte ratio(MLR) in comparison with hs-CRP in these patients. Method: This observational cohort study included patients with chest pain and nonobstructive coronary artery disease <40% stenosis in major coronary arteries on clinically indicated elective coronary angiography who underwent invasive physiological coronary reactivity testing for evaluation of coronary vasomotor function between 1997-2021. Preprocedural MLR was categorized as high (≥0.30) or low (<0.30) using the best cutoff value for predicting major adverse cardiovascular and cerebrovascular events (MACCE) determined by ROC curves. Preprocedural Hs-CRP levels ≥1 and <1 mg/L were classified as high or low, respectively. MACCE comprised cardiovascular death, nonfatal myocardial infarction, heart failure, stroke, and late revascularization. Kaplan-Meier plots, Log-rank test, and Cox regression analysis were used for analysis. Result: Among 892 patients (median age 52 [IQR: 43- 61] years, 69% females), 40% had high MLR and 49% had high hs-CRP, respectively. Over a 10-year follow-up, 125 patients (14%) experienced MACCE. In univariable analysis, high MLR level ( p < 0.001 ) and high hs-CRP ( p = 0.045) were associated with worse outcomes. (Figure 1) In multivariate Cox regression after adjusting for age, body mass index, creatinine, hypertension, hyperlipidemia, and diabetes mellitus, MLR remained a significant predictor of MACCE (HR=1.75, 95% CI=1.20- 2.55, p = 0.004), whereas hs-CRP lost its significance (HR=1.26, 95% CI=0.857- 1.848, p=0.241). Stratifying patients into four groups of high MLR/high hs-CRP (21%), high MLR/low hs-CRP (19%), low MLR/high hs-CRP (28%), and low MLR/low hs-CRP (32%) revealed that high MLR was associated with increased MACCE in both groups with high and low hs-CRP, while in both high MLR and low MLR groups, hs-CRP levels made no difference in MACCE incidences. (Figure 2). Conclusion: elevated MLR is a strong independent predictor of MACCE in patients with ANOCA, superior to hs-CRP. These findings highlight the potential of MLR as a valuable, readily available marker for risk stratification in early atherosclerosis.
Abstract 4365980: Real-World analysis of systemic vascular resistance using a cuffless photoplethysmography-based device for 24-hours ambulatory blood pressure monitoring across diverse patient groups

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4365980

Introduction: Photoplethysmography-based (PPG) devices represent a significant advancement in noninvasive cardiovascular monitoring. These cuffless technologies enable assessment of hemodynamic parameters with improved comfort, usability and compliance. Modern PPG systems have expanded their capabilities to include advanced metrics such as systemic vascular resistance (SVR) and cardiac output (CO). Many antihypertensive drugs lower blood pressure by reducing SVR through vasodilatation of the systemic and renal vasculature. Limited data is available on SVR during ambulatory monitoring. PPG devices become more common as they allow us to assess SVR in real life, in ambulatory blood pressure monitoring (ABPM) patients. Aim: To evaluate and compare SVR using the Biobeat (WP613) device across patient groups. Methods: Adults from the Hypertension Clinic at University of Miami, Florida, from Aug. 2023–Jan. 2025 underwent 24-h ABPM monitoring using Biobeat device. Patient data was matched with Biobeat. PPG data was available every 15 minutes; The raw data included SBP and DBP, the heart rate, stroke volume, CO and SVR. Results: A total of 539 patients underwent PPG ABPM during the study period. The median was 62 (IQR 54, 71) years, with 57% females (Tab 1) . Patients were defined as hypertensive per AHA 2017 guidelines [SBP≥130 and DBP≥80 mmHg]. Overall, 265 patients were classified as having normal BP, 95 as having isolated systolic hypertension, and 179 as having mixed hypertension. Within the Mix-HTN group, 42 patients had isolated diastolic hypertension and the remaining 137 systolic and diastolic hypertension (Fig 2) . In subgroup analysis (Fig 3); SVR was significantly different between the groups: lowerst in No/C-HTN and highest in Mix-HTN. particularly among the mixed-hypertension group, SVR was higher in the Systolic and Diastolic HTN compared to the Isolated diastolic HTN group. Among the No/C-HTN group, 60 patients were not hypertensives and 205, were hypertensives on at least 1 drug. The SVR was not statistically significant between these 2 subgroups, suggesting that SVR may be a helpful target biomarker used to up-titrate antihypertensives. Conclusion: PPG devices offer a valuable enhancement to conventional ABPM by providing additional physiological measurements such as SVR that can help differentiate between various hypertension phenotypes and potentially provide personalized therapy that target the driver of hypertension.
Abstract 4362007: Sex-Specific Prognostic Implications of Coronary Physiology and Microvascular Dysfunction

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4362007

Background: Sex differences in coronary physiology have been reported, particularly with regard to higher resting coronary flow in women. Resting flow is independently associated with clinical outcomes, irrespective of the presence of coronary microvascular dysfunction (CMD), but its sex-specific prognostic significance remains unclear. Aims: This study aimed to compare the prognostic implications of resting flow and CMD between sexes among patients with angina and non-obstructive coronary arteries (ANOCA). Methods: We studied 1194 patients with ANOCA undergoing coronary reactivity testing. Endothelium-independent microvascular function was assessed by coronary flow reserve (CFR) during adenosine-induced hyperemia, and endothelium-dependent function by coronary blood flow (CBF) increase during intracoronary acetylcholine infusion. Endothelium-dependent CMD was defined as <50% CBF increase, and endothelium-independent CMD as CFR <2.5. Cardiovascular events were defined as a composite of all-cause death, myocardial infarction and heart failure. Results: The median age of the study population was 52 years, and 71.1% were women. Resting average peak velocity (rAPV) and baseline CBF (bCBF) were significantly higher in women (p<0.001 and p=0.006, respectively). Survival analysis revealed that both elevated rAPV and bCBF were significantly associated with worse outcomes in men (p<0.001 and p=0.036, respectively, Figure 1), whereas no such associations were observed in women. In Cox proportional hazard analysis, sex showed a significant interaction effect with elevated rAPV (interaction p=0.014). Furthermore, endothelium-independent CMD was significantly associated with adverse outcomes in both men and women (p=0.011 and p=0.004, respectively), whereas endothelium-dependent CMD was significantly associated with prognosis only in men (p=0.006). Among men with endothelium-dependent CMD, the subtype characterized by higher bCBF was particularly associated with worse prognosis (p=0.001, Figure 2). Conclusions: In patients with ANOCA, men had lower resting coronary flow than women. However, its association with adverse outcomes was observed only in men, especially in those with impaired endothelial function. These results suggest that coronary physiology should be interpreted differently by sex, and that clinical decisions should be adjusted accordingly.