Background: Medial elbow injuries are common among baseball pitchers. Easily accessed methods to assess medial elbow stress may be useful in identifying individuals with increased injury risk. Hypothesis: Pitch velocity (PV) is positively associated with higher medial elbow adduction moments. Study Design: Cohort study; Level of evidence, 2. Methods: Participants included 26 uninjured high school pitchers, 15 to 18 years in age. Three-dimensional data and PV were collected as athletes threw 10 fastballs for strikes to a regulation-distance target. Variables of interest were the normalized peak internal elbow adduction moment and peak PV. Linear regression was performed to evaluate the influence of PV on the adduction moment. Results: For the group, mean PV was 71 mph (range, 58-81 mph), and the adduction moment was 0.558 Nm/Ht × mass (range, 0.378-0.723). PV was positively associated with the adduction moment ( P < 0.01, R 2 = 0.373). Conclusions: Talented young pitchers may be more susceptible to elbow injuries as a consequence of a biomechanical coupling between PV and upper extremity joint moments. Clinical Relevance: PV may be measured easily and serve as an indicator of medial elbow stress.
Relationship Between the Medial Elbow Adduction Moment During Pitching and Ulnar Collateral Ligament Appearance During Magnetic Resonance Imaging Evaluation
The American Journal of Sports Medicine | February 19, 2011 | Volume: 39 | Issue: 6 | Pages: 1233-1237
Background: Medial elbow distraction during pitching as the primary mechanism contributing to adaptations in ulnar collateral ligament (UCL) appearance during magnetic resonance imaging (MRI) evaluation has not been established. Hypothesis: Uninjured high school–aged pitchers with unilateral adaptations of the UCL exhibit a higher peak internal elbow adduction moment than those without UCL adaptations. Study Design: Cohort study (Prevalence); Level of evidence, 2. Methods: Twenty uninjured, asymptomatic high school–aged pitchers underwent bilateral elbow MRI examinations. Three-dimensional motion analysis testing was performed to collect throwing arm biomechanics as participants pitched from an indoor mound. Nonparametric tests were performed to compare peak internal elbow adduction moment in uninjured participants with and without adaptations in UCL appearance and to determine the nature of the relationship between the peak internal adduction moment and UCL appearance. Results: Uninjured participants with UCL thickening exhibited a higher peak internal elbow adduction moment of 53.3 ± 6.8 N·m compared with uninjured participants without adaptations in UCL appearance, 38.8 ± 10.9 N·m ( P = .05), as higher moments were correlated with ligament thickening (correlation coefficient, 0.45) ( P = .02). Conclusion: This study establishes the association between medial elbow distraction captured by the internal adduction moment during pitching and UCL adaptations visible during MRI evaluation.
Magnetic Resonance Imaging of the Throwing Elbow in the Uninjured, High School–Aged Baseball Pitcher
The American Journal of Sports Medicine | January 12, 2011 | Volume: 39 | Issue: 4 | Pages: 722-728
Background: Tissue adaptations in response to pitching are an expected finding during magnetic resonance imaging (MRI) evaluation of the throwing elbow of adult pitchers. These changes are considered normal in the absence of symptom complaints. It is unclear when during the playing career these tissue adaptations are initiated. Hypothesis: Abnormalities in the appearance of the throwing elbow compared with the nonthrowing elbow would be visible during MRI assessment of this asymptomatic population of high school–aged throwers. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty-three uninjured, asymptomatic male high school–aged baseball pitchers (mean age, 16 years) with no history of elbow injury were recruited for the study. Participants had a minimum of 3 years’ experience with pitching as their primary position (mean experience, 6 years). Bilateral elbow MRI examinations were performed using a standardized protocol including fast spin-echo proton-density (axial and coronal), T1-weighted (sagittal), and T2-weighted fat-saturated (axial, sagittal, and coronal) sequences. Osteoarticular, ligamentous, musculotendinous, and neural structures were evaluated and compared bilaterally. The images were reviewed by a musculoskeletal radiologist who was blinded to all the gathered data on these athletes, including limb dominance. Results: Three participants (13%) had no abnormalities. Fifteen individuals (65%) had asymmetrical anterior band ulnar collateral ligament thickening, including 4 individuals who also had mild sublime tubercle/anteromedial facet edema. Fourteen participants (61%) had posteromedial subchondral sclerosis of the ulnotrochlear articulation, including 8 (35%) with a posteromedial ulnotrochlear osteophyte, and 4 (17%) with mild posteromedial ulnotrochlear chondromalacia. Ten individuals (43%) had multiple abnormal findings in the throwing elbow. Conclusion: Thickening of the anterior band of the ulnar collateral ligament and posteromedial subchondral sclerosis of the trochlea are common findings in the high school–aged pitcher and may be considered normal clinical findings in the absence of symptom complaints. Other changes in tissue appearance of the throwing elbow are uncommon in this age group and should be regarded with a higher level of caution when evaluating for the presence of injury. An understanding of the MRI appearance of the uninjured youth pitcher is necessary for clinicians to distinguish between normal adaptations and the presence of injury.
Comparison of Shoulder Range of Motion, Strength, and Playing Time in Uninjured High School Baseball Pitchers Who Reside in Warm- and Cold-Weather Climates
The American Journal of Sports Medicine | November 4, 2010 | Volume: 39 | Issue: 2 | Pages: 320-328
Background: There is an assumption that baseball athletes who reside in warm-weather climates experience larger magnitude adaptations in throwing shoulder motion and strength compared with their peers who reside in cold-weather climates. Hypotheses: (1) The warm-weather climate (WWC) group would exhibit more pronounced shoulder motion and strength adaptations than the cold-weather climate (CWC) group, and (2) the WWC group would participate in pitching activities for a greater proportion of the year than the CWC group, with the time spent pitching predicting throwing shoulder motion and strength in both groups. Study Design: Cross-sectional study; Level of evidence, 3. Methods: One hundred uninjured high school pitchers (50 each WWC, CWC) were recruited. Rotational shoulder motion and isometric strength were measured and participants reported the number of months per year they pitched. To identify differences between groups, t tests were performed; linear regression was used to determine the influence of pitching volume on shoulder motion and strength. Results: The WWC group pitched more months per year than athletes from the CWC group, with the number of months spent pitching negatively related to internal rotation motion and external rotation strength. The WWC group exhibited greater shoulder range of motion in all planes compared with the CWC group, as well as significantly lower external rotation strength and external/internal rotation strength ratios. There was no difference in internal rotation strength between groups, nor a difference in the magnitude of side-to-side differences for strength or motion measures. Conclusion: Athletes who reside in cold- and warm-weather climates exhibit differences in throwing shoulder motion and strength, related in part to the number of months spent participating in pitching activities. The amount of time spent participating in pitching activities and the magnitude of range of motion and strength adaptations in athletes who reside in warm-weather climates may make these athletes more susceptible to throwing-related injuries.
Short-term repeatability of joint space width measurements using a magnetic resonance imaging compatible knee positioning device
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | February 15, 2010 | Volume: 224 | Issue: 9 | Pages: 1061-1071
The purpose of this study was to evaluate a magnetic resonance imaging (MRI) compatible knee positioning device to aid in minimizing intratechnologist and intertechnologist differences of minimum joint space width (JSW) measurements. Five subjects were scanned by two separate technologists, with and without an MRI-compatible positioning device. A semi-automated program calculated the minimum JSW of the tibiofemoral and patellofemoral joints. The scan-to-scan repeatability was evaluated from measurements between serial scans without subject repositioning, and the intratechnologist and intertechnologist repeatabilities were evaluated when the subject was removed from the magnet and repositioned by an individual technologist. The root mean square (RMS) error of the JSW measurements was also calculated. All measures of scan-to-scan repeatability and intratechnologist repeatability were unchanged with the MRI-compatible positioning device. The intertechnologist repeatability decreased from 0.70 to 0.42 mm, and the RMS error was significantly reduced ( P = 0.0006) from 0.26 to 0.15 mm for the tibiofemoral joint. The variability of patellofemoral JSW measurements increased when using the positioning device; however, the increases were not statistically significant. The intertechnologist repeatability increased from 1.55 to 1.79 mm, and the RMS error increased from 0.58 to 0.73 mm. The MRI-compatible positioning device was successful at reducing JSW measurement variability at the tibiofemoral joint. The increase in measurement variability at the patellofemoral joint may be due to local incongruities of the articular surfaces. An MRI-compatible positioning device may be beneficial for quantitative longitudinal studies evaluating knee joint health.
An Ultraminiature MEMS Pressure Sensor With High Sensitivity for Measurement of Intramuscular Pressure (IMP) in Patients With Neuromuscular Diseases
Journal of Medical Devices | September 3, 2009 | Volume: 3 | Issue: 3 | Pages: No page available
An ultraminiature micropressure sensor to accurately measure intramuscular pressure has been developed. The MEMS sensor is fabricated through surface micromachining and consists of a capacitive array of eight 150 μm diameter sensing membranes connected in parallel. The membranes have been vacuum-sealed via a subsequent deposition and patterning batch microfabrication step. A deep reactive ion etcher (DRIE) based postfabrication self-release has been utilized to fabricate individual devices. Each device has an outline that incorporates specially designed “anchor” structures that are utilized to attach on the muscle tissue during measurements to minimize the effect of muscle contractions on sensor readings. Electrical isolation of the wire bonds and bonding pads has been accomplished by utilizing glob-topping technique. The fabricated sensor performance has been experimentally validated inside a pressure chamber. The current sensors have 0.2 mm Hg pressure resolution in the ±19 mm Hg dynamic range with negligible hysteresis and show a flat frequency response in the 0–5.5 Hz experimental test range.
Constitutive Modeling of Skeletal Muscle Tissue With an Explicit Strain-Energy Function
Journal of Biomechanical Engineering | November 11, 2008 | Volume: 130 | Issue: 6 | Pages: No page available
While much work has previously been done in the modeling of skeletal muscle, no model has, to date, been developed that describes the mechanical behavior with an explicit strain-energy function associated with the active response of skeletal muscle tissue. A model is presented herein that has been developed to accommodate this design consideration using a robust dynamical approach. The model shows excellent agreement with a previously published model of both the active and passive length-tension properties of skeletal muscle.
Prediction of Antagonistic Muscle Forces Using Inverse Dynamic Optimization During Flexion/Extension of the Knee
Journal of Biomechanical Engineering | February 21, 2008 | Volume: 121 | Issue: 3 | Pages: 316-322
This paper examined the feasibility of using different optimization criteria in inverse dynamic optimization to predict antagonistic muscle forces and joint reaction forces during isokinetic flexion/extension and isometric extension exercises of the knee. Both quadriceps and hamstrings muscle groups were included in this study. The knee joint motion included flexion/extension, varus/valgus, and internal/external rotations. Four linear, nonlinear, and physiological optimization criteria were utilized in the optimization procedure. All optimization criteria adopted in this paper were shown to be able to predict antagonistic muscle contraction during flexion and extension of the knee. The predicted muscle forces were compared in temporal patterns with EMG activities (averaged data measured from five subjects). Joint reaction forces were predicted to be similar using all optimization criteria. In comparison with previous studies, these results suggested that the kinematic information involved in the inverse dynamic optimization plays an important role in prediction of the recruitment of antagonistic muscles rather than the selection of a particular optimization criterion. Therefore, it might be concluded that a properly formulated inverse dynamic optimization procedure should describe the knee joint rotation in three orthogonal planes.