Citations 96

Analysis of fluid movement in skeletal muscle using fluorescent microspheres

Muscle & Nerve | February 2, 2016 | Volume: 54 | Issue: 3 | Pages: 444-450

10.1002/mus.25063 | PMID 26833456

ABSTRACTIntroductionRegional variability in interstitial fluid pressure confounds use of intramuscular pressure measurement to assess muscle force. It is hypothesized that interstitial flow is dependent on intramuscular pressure. The goal of this study was to assess the feasibility of using fluorescent microspheres to evaluate movement of interstitial fluid in skeletal muscle.MethodsTwo diameters of fluorescent microspheres were injected into the rat tibialis anterior during both static (n = 6) and passively lengthened (10% strain) experimental conditions (n = 6). Microsphere dispersion was evaluated using confocal imaging of transverse muscle sections.ResultsFluorescent microspheres tracked interstitial fluid while not penetrating the muscle fiber. When compared with the static condition, significantly greater dispersion (P = 0.003) was seen with passively lengthened conditions (17 ± 9% vs. 31 ± 7%, respectively). Dispersion did not differ for the 2 microsphere sizes (P = 0.811).ConclusionsFluorescent microspheres track movement of interstitial fluid, and dispersion is dependent on passive lengthening. Muscle Nerve 54: 444–450, 2016
Gait Emulator for Evaluation of Ankle–Foot Prostheses Capable of Turning1

Journal of Medical Devices | July 16, 2015 | Volume: 9 | Issue: 3 | Pages: No page available

10.1115/1.4030546

Ankle mechanics during sidestep cutting implicates need for 2-degrees of freedom powered ankle-foot prostheses

Journal of Rehabilitation Research and Development | June 2, 2015 | Volume: 52 | Issue: 1 | Pages: 97-112

10.1682/jrrd.2014.02.0043 | PMID 26186014

Assessment of Gait Kinetics Using Triaxial Accelerometers

Journal of Applied Biomechanics | July 10, 2014 | Volume: 30 | Issue: 5 | Pages: 668-674

10.1123/jab.2014-0037 | PMID 25010675

Repeated durations of dynamic activity with high ground reaction forces (GRFs) and loading rates (LRs) can be beneficial to bone health. To fully characterize dynamic activity in relation to bone health, field-based measurements of gait kinetics are desirable to assess free-living lower-extremity loading. The study aims were to determine correlations of peak vertical GRF and peak vertical LR with ankle peak vertical accelerations, and of peak resultant GRF and peak resultant LR with ankle peak resultant accelerations, and to compare them to correlations with tibia, thigh, and waist accelerations. GRF data were collected as ten healthy subjects (26 [19–34] years) performed 8–10 walking trials at velocities ranging from 0.19 to 3.05 m/s while wearing ankle, tibia, thigh, and waist accelerometers. While peak vertical accelerations of all locations were positively correlated with peak vertical GRF and LR (r2 > .53, P < .001), ankle peak vertical accelerations were the most correlated (r2 > .75, P < .001). All peak resultant accelerations were positively correlated with peak resultant GRF and LR (r2 > .57, P < .001), with waist peak resultant acceleration being the most correlated (r2 > .70, P < .001). The results suggest that ankle or waist accelerometers give the most accurate peak GRF and LR estimates and could be useful tools in relating physical activity to bone health.
Tibiofemoral alignment in posterior stabilized total knee arthroplasty: Static alignment does not predict dynamic tibial plateau loading

Journal of Orthopaedic Research | May 12, 2014 | Volume: 32 | Issue: 8 | Pages: 1068-1074

10.1002/jor.22644 | PMID 24820681

ABSTRACTFor total knee arthroplasty (TKA), neutral mechanical alignment produces balanced static knee loading. Dynamically, knee loading is affected by more than limb static alignment. We compared static and dynamic knee loading following TKA. Fifteen TKA patients were evaluated pre‐operatively and 2 months and 2 years post‐operatively. Tibiofemoral angles and medial tibial plateau loading were calculated. Pre‐operatively, static medial load was greater for varus than valgus knees. Post‐operatively, no relationship existed between tibiofemoral angle and static medial plateau load. Pre‐operatively and post‐operatively, dynamic medial load was not dependent on tibiofemoral angle. While all patients achieved equal static plateau load distributions at 2 years, only 47% had dynamic medial load distributions of 50 ± 10%. Static tibiofemoral alignment alone does not predict dynamic tibial loading. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:???–???, 2014.
Tensile Material Properties of Skeletal Muscle Tissue in Longitudinal and Transverse Directions

ASME 2008 Summer Bioengineering Conference, Parts A and B | March 13, 2014 | Volume: No volume available | Issue: No issue available | Pages: 1027-1028

10.1115/sbc2008-193043

Since Blix noted that force varies with muscle length [1], many investigators have worked to characterize the passive length-tension properties of skeletal muscle in the tissue’s fiber direction [2]. However, few reports have examined the properties of muscle in either transverse extension or in longitudinal shear [3–4]. Material properties in these three directions are needed to fully characterize computational models, which generally describe muscle as being transversely isotropic, hyperelastic, and isovolumetric [3–6]. Further, previous studies reporting tri-planar material properties indicate that muscle tissue is stiffer in the transverse direction compared to the longitudinal direction [3–4]. This counters conventional notions of transversely isotropic materials, which are generally stiffer in the fiber direction.
Experimental Validation of a Tibiofemoral Model for Analyzing Joint Force Distribution

ASME 2008 Summer Bioengineering Conference, Parts A and B | March 13, 2014 | Volume: No volume available | Issue: No issue available | Pages: 767-768

10.1115/sbc2008-192775

Mathematical models are non-invasive tools used for analyzing biomechanical conditions. Various models of the knee using the finite element analysis technique [1–6] and rigid body spring model (RBSM) [7] have been developed to predict pressure distribution in articulating joints, although the RBSM is considered the simplest of the modeling techniques, while still effectively predicting load distribution. These models can be used to study altered joint loading, which causes a degeneration of the articular cartilage, in order to gain an understanding of the etiology of osteoarthritis (OA). The purpose of this study is to develop a subject-specific analytical knee model using the RBSM approach that incorporates subject-specific geometry, joint health, and loading patterns to predict tibiofemoral load distributions.
Constitutive Modeling of Skeletal Muscle Tissue

ASME 2007 Summer Bioengineering Conference | March 12, 2014 | Volume: No volume available | Issue: No issue available | Pages: 873-874

10.1115/sbc2007-175848

The main functions of the human musculoskeletal system are to sustain loads and provide mobility. Bones and joints themselves cannot produce movement; skeletal muscles provide the ability to move. Knowledge of muscle forces during given activities can provide insight into muscle mechanics, muscle physiology, musculoskeletal mechanics, neurophysiology, and motor control. However, clinical examinations or instrumented strength testing only provides information regarding muscle groups. Musculoskeletal models are typically needed to calculate individual muscle forces.
Accelerations of the Waist and Lower Extremities Over a Range of Gait Velocities to Aid in Activity Monitor Selection for Field-Based Studies

Journal of Applied Biomechanics | March 6, 2014 | Volume: 30 | Issue: 4 | Pages: 581-585

10.1123/jab.2013-0264 | PMID 24610379

This study aimed to define accelerations measured at the waist and lower extremities over a range of gait velocities to provide reference data for choosing the appropriate accelerometer for field-based human activity monitoring studies. Accelerations were measured with a custom activity monitor (± 16g) at the waist, thighs, and ankles in 11 participants over a range of gait velocities from slow walking to running speeds. The cumulative frequencies and peak accelerations were determined. Cumulative acceleration amplitudes for the waist, thighs, and ankles during gait velocities up to 4.8 m/s were within the standard commercial g-range (± 6g) in 99.8%, 99.0%, and 96.5% of the data, respectively. Conversely, peak acceleration amplitudes exceeding the limits of many commercially available activity monitors were observed at the waist, thighs, and ankles, with the highest peaks at the ankles, as expected. At the thighs, and more so at the ankles, nearly 50% of the peak accelerations would not be detected when the gait velocity exceeds a walking velocity. Activity monitor choice is application specific, and investigators should be aware that when measuring high-intensity gait velocity activities with commercial units that impose a ceiling at ± 6g, peak accelerations may not be measured.
Identification of True Knee Flexion Axis Despite Marker Misplacement Using Principal Component Analysis

Volume 1B: Extremity; Fluid Mechanics; Gait; Growth, Remodeling, and Repair; Heart Valves; Injury Biomechanics; Mechanotransduct | January 29, 2014 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/sbc2013-14137

Gait analysis is useful for revealing pathologic tibial rotation in children with cerebral palsy (CP), thus guiding interventions of de-rotational osteotomy [1]. Surface marker misplacement may cause an inaccurate definition of the knee flexion axis, which generates downstream artifacts such as cross talk between knee rotation angles and internal rotation errors, misleading these patients’ assessments and surgical interventions [2,3]. Therefore, the purpose of this study was to develop and evaluate a novel method for defining the true knee flexion axis from existing marker trajectories during gait. We hypothesized that the devised method would accurately quantify the offset in the flexion axis due to a systematically misplaced marker and correct the downstream crosstalk and rotation errors of the knee joint angles associated with the marker misplacement.