Citations 96

Dynamic joint forces during knee isokinetic exercise

The American Journal of Sports Medicine | June 21, 2007 | Volume: 19 | Issue: 3 | Pages: 305-316

10.1177/036354659101900317 | PMID 1867339

This study analyzed forces in the tibiofemoral and pa tellofemoral joints during isokinetic exercise using an analytical biomechanical model. The results show that isokinetic exercise can produce large loads on these joints, especially during extension exercises. The tibio femoral compressive force (4.0 body weight) is approx imately equal to that obtained during walking but it occurs at 55° of knee flexion. Anterior shear forces (resisting force to anterior drawer) exist during exten sion exercise at less than 40° of knee flexion, with a maximum of 0.3 body weight. Posterior shear forces (resisting force to posterior drawer) exist during exten sion exercise at knee joint angles greater than 40° and during the flexion portion of isokinetic exercise. The maximum posterior shear force is 1.7 body weight. The patellofemoral joint can encounter loads as high as 5.1 body weight which are 10 times higher than during straight leg raises. These results suggest that isokinetic exercise should be used cautiously in patients with knee lesions.
The relationship of strength and jump height in figure skaters

The American Journal of Sports Medicine | June 21, 2007 | Volume: 18 | Issue: 4 | Pages: 400-405

10.1177/036354659001800412 | PMID 2403190

Eighteen junior elite figure skaters were filmed while performing axel and double axel jumps. These same skaters were assessed for strength of the shoulders, knees, and hips at multiple angular velocities using a Cybex II system. The height of the jumps was signifi cantly correlated with the strength data. Knee exten sion at 240 deg/sec and shoulder abduction at 300 deg/sec were shown to be the most important strength parameters in determining the height of the jump. This information may be useful for designing strength train ing programs for figure skaters.
The Impact of Overt and Subclinical Hyperthyroidism on Skeletal Muscle

Thyroid | April 28, 2006 | Volume: 16 | Issue: 4 | Pages: 375-380

10.1089/thy.2006.16.375 | PMID 16646684

Biomechanical Efficiency of Wrist Guards as a Shock Isolator

Journal of Biomechanical Engineering | March 7, 2006 | Volume: 128 | Issue: 2 | Pages: 229-234

10.1115/1.2165695 | PMID 16524335

Despite the use of wrist guards during skate- and snowboard activities, fractures still occur at the wrist or at further proximal locations of the forearm. The main objectives of this study were to conduct a human subject testing under simulated falling conditions for measurement of the impact force on the hand, to model wrist guards as a shock isolator, to construct a linear mass-spring-damper model for quantification of the impact force attenuation (Q-ratio) and energy absorption (S-ratio), and to determine whether wrist guards play a role of an efficient shock isolator. While the falling direction (forward and backward) significantly influenced the impact responses, use of wrist guards provided minimal improvements in the Q- and S-ratios. It was suggested based on the results under the submaximal loading conditions that protective functions of the common wrist guard design could be enhanced with substantial increase in the damping ratio so as to maximize the energy absorption. This would bring forth minor deterioration in the impact force attenuation but significant increase in the energy absorption by 19%, which would help better protection against fall-related injuries of the upper extremity.
A kinematic method to calculate the workspace of the trapeziometacarpal joint

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | April 6, 2004 | Volume: 218 | Issue: 2 | Pages: 143-149

10.1243/095441104322984031 | PMID 15116901

The specific aim of this study was to develop a quantitative method and a kinematic method to evaluate the maximal workspace of the trapeziometacarpal (TM) joint. Six fresh-frozen human cadaver hands were disarticulated 4 cm proximal to the wrist joint and used in this experiment. The three-dimensional motion data of the TM joint was collected by an electromagnetic tracking device at 30 Hz. The workspace was reconstructed according to a complete set of motion data included circumduction, flexion-extension and abduction-adduction. A spherical fitting technique was used to obtain a sphere encompassing all the motion trajectories and estimating the centre of the sphere. The surface area of the maximal TM workspace, located on the one part of the sphere surface, was calculated by surface integration. The interclass correlation coefficient values for the reliability estimation of the repeated measurements of the radius and surface area of all specimens were 0.91 and 0.98 respectively. The mean coefficients of variance of the measured radius and the surface area were 2.04 per cent and 3.65 per cent respectively. The results also showed that using a spherical model to calculate the maximal workspace as an index for assessing TM joint impairment is practical.
IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAIT

Journal of Musculoskeletal Research | April 22, 2003 | Volume: 05 | Issue: 02 | Pages: 113-121

10.1142/s0218957701000490

The purpose of this study is to develop an electromechanical system for dynamic simulation of the stance phase of a human gait using cadaveric foot specimens. The system can be used for quantification of foot and ankle pathomechanics and design of foot and ankle reconstructive surgeries. Servo-pneumatic systems were used for application of the tibial weight loading and muscle loadings. A four-bar mechanism was constructed to provide the progressive motion of a tibia during the simulation while the external loadings were simultaneously applied. Muscle loadings were estimated based on the physiological cross-sectional area and normal electromyography (EMG) data with the assumption of the linear EMG–force relationship. Ad hoc tuning of the unknown muscle gains was conducted until a reasonable match with the normal vertical ground reaction force profile, center of pressure advancement, and characteristic foot motion events (heel strike, foot flat, heel rise and toe-off) could be made. Three cadaver feet and an artificial foot were tested with five repeated trials. The simulator reproduced the stance phase of a human gait in the sagittal plane with reasonable accuracy and consistency without compromising either kinematics or kinetics of the foot and ankle complex.