Back to Authors

Kiaii, Bob

A5068907752 | I25041050

Mayo Clinic

for the SURTAVI Trial Investigators

Citations 6

Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients

JAMA Cardiology | August 24, 2022 | Volume: 7 | Issue: 10 | Pages: 1000

10.1001/jamacardio.2022.2695 | PMID 36001335

Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Cardiac surgeons' concerns, perceptions, and responses during the COVID‐19 pandemic

Journal of Cardiac Surgery | June 12, 2021 | Volume: 36 | Issue: 9 | Pages: 3040-3051

10.1111/jocs.15681 | PMID 34118080

Investigating Perioperative Heart Migration during Robot-Assisted Coronary Artery Bypass Grafting Interventions

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 3, 2019 | Volume: 6 | Issue: 5 | Pages: 323-330

10.1177/155698451100600507

Augmented Reality Image Guidance Improves Navigation for Beating Heart Mitral Valve Repair

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 3, 2019 | Volume: 7 | Issue: 4 | Pages: 274-281

10.1177/155698451200700408

Augmented Reality Image Guidance Improves Navigation for Beating Heart Mitral Valve Repair

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | November 2, 2012 | Volume: 7 | Issue: 4 | Pages: 274-281

10.1097/imi.0b013e31827439ea | PMID 23123995

Objective Emerging off-pump beating heart valve repair techniques offer patients less invasive alternatives for mitral valve (MV) repair. However, most of these techniques rely on the limited spatial and temporal resolution of transesophageal echocardiography (TEE) alone, which can make tool visualization and guidance challenging. Methods Using a magnetic tracking system and integrated sensors, we created an augmented reality (AR) environment displaying virtual representations of important intracardiac landmarks registered to biplane TEE imaging. In a porcine model, we evaluated the AR guidance system versus TEE alone using the transapically delivered NeoChord DS1000 system to perform MV repair with chordal reconstruction. Results Successful tool navigation from left ventricular apex to MV leaflet was achieved in 12 of 12 and 9 of 12 (P = 0.2) attempts with AR imaging and TEE alone, respectively. The distance errors of the tracked tool tip from the intended midline trajectory (5.2 ± 2.4 mm vs 16.8 ± 10.9 mm, P = 0.003), navigation times (16.7 ± 8.0 seconds vs 92.0 ± 84.5 seconds, P = 0.004), and total path lengths (225.2 ± 120.3 mm vs 1128.9 ± 931.1 mm, P = 0.003) were significantly shorter in the AR-guided trials compared with navigation with TEE alone. Furthermore, the potential for injury to other intracardiac structures was nearly 40-fold lower when using the AR imaging for tool navigation. The AR guidance also seemed to shorten the learning curve for novice surgeons. Conclusions Augmented reality–enhanced TEE facilitates more direct and safe intracardiac navigation of the NeoChord DS tool from left ventricular apex to MV leaflet. Tracked tool path results demonstrate fourfold improved accuracy, fivefold shorter navigation times, and overall improved safety with AR imaging guidance.
Investigating Perioperative Heart Migration during Robot-Assisted Coronary Artery Bypass Grafting Interventions

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | October 28, 2011 | Volume: 6 | Issue: 5 | Pages: 323-330

10.1097/imi.0b013e3182374e7e | PMID 22436709

Objective For robot-assisted coronary artery bypass graft interventions, surgeons typically use a preoperative thoracic computed tomography scan of the patient to plan the procedure. However, the cardiac anatomy is prone to changes induced perioperatively in the effort to access the heart and surgical targets, which, in turn, may invalidate the initial plan. This article presents a method to estimate the perioperative heart migration, information which can be further exploited to refine the preoperative surgical plan. Methods Tracked transesophageal ultrasound images of four patients’ hearts were acquired at each stage in the procedure: before lung deflation, after lung deflation, and after both lung deflation and CO 2 thoracic insufflation. Anatomic features of interest—the mitral and aortic valves—were identified from each dataset, and their movement between the different procedure stages was recorded and used to estimate the global heart displacement. Moreover, the local morphology of the features of interest was investigated to provide insight on the extent of the deformation the heart has undergone during the workflow. Results The study suggested that the heart does undergo substantial displacement—on the order of 10 to 15 mm in each direction (axial, coronal, and sagittal) after lung deflation and CO 2 thoracic insufflation. However, no significant differences (P > 0.1) were observed in the morphologic characteristics of the features of interest across the multiple workflow stages, suggesting that local deformations occur at a much smaller scale compared with the global migration. Conclusions The quantification of the perioperatively induced changes is critical to track the displacement of the heart and surgical targets. The recorded migration patterns should not be ignored but rather be used to update the surgical plan to better suit the intraoperative environment.