IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Interictal Scalp Electroencephalography and Intraoperative Electrocorticography in Magnetic Resonance Imaging–Negative Temporal Lobe Epilepsy Surgery
BackgroundRecent studies have shown that magnetic resonance imaging (MRI) of patients with pacemakers can be safely performed under careful monitoring, but they excluded patients with recently implanted devices. Patients with recent implants may be at a greater risk for complications during MRI imaging due to lack of lead and wound maturity.MethodsWe implemented a clinical protocol for MRI imaging of patients with implanted cardiac devices, and prospectively collected data. For this study, we retrospectively analyzed two groups of patients: those with recently implanted (≤42 days) and nonrecently implanted (>42 days) leads at the time of MRI scanning. All devices were interrogated before and after scanning, and were reprogrammed during the scan as per protocol.ResultsOf the 219 scans (in 171 patients), eight included patients with recently implanted (range: 7–36 days) and 211 with only nonrecently implanted pacemaker leads. During the scan, there were no complications in the early or late group. In one patient imaged 79 days postimplant, frequent premature ventricular complexes were noted during the scan, requiring no action. No patient reported pain during or immediately after the procedure. No clinically significant changes in function were seen at subsequent follow up (average 104 days post‐MRI). Compared to patients with nonrecently implanted leads, there was no difference in any parameter between the two groups.ConclusionsWith a strong clinical indication and with careful monitoring, MRI imaging is feasible in patients with recently implanted pacemakers, although experience is limited.
Scalp and Intracranial EEG in Medically Intractable Extratemporal Epilepsy with Normal MRI
ISRN Neurology | July 29, 2012 | Volume: 2012 | Issue: No issue available | Pages: 1-9
Purpose. To investigate EEG and SPECT in the surgical outcome of patients with normal MRI (nonlesional) and extratemporal lobe epilepsy. Methods. We retrospectively identified 41 consecutive patients with nonlesional extratemporal epilepsy who underwent epilepsy surgery between 1997 and 2007. The history, noninvasive diagnostic studies (scalp EEG, MRI, and SPECT) and intracranial EEG (iEEG) monitoring was reviewed. Scalp and iEEG ictal onset patterns were defined. The association of preoperative studies and postoperative seizure freedom was analyzed using Kaplan-Meier analysis, log-rank test, and Cox proportional hazard. Results. Thirty-six of 41 patients had adequate information with a minimum of 1-year followup. Favorable surgical outcome was identified in 49% of patients at 1 year, and 35% at 4-year. On scalp EEG, an ictal onset pattern consisting of focal beta-frequency discharge (>13–125 Hz) was associated with favorable surgical outcome (P=0.02). Similarly, a focal fast-frequency oscillation (>13–125 Hz) on iEEG at ictal onset was associated with favorable outcome (P=0.03). Discussion. A focal fast-frequency discharge at ictal onset identifies nonlesional MRI, extratemporal epilepsy patients likely to have a favorable outcome after resective epilepsy surgery.
Patient Safety Event Reporting in a Large Radiology Department
American Journal of Roentgenology | August 23, 2011 | Volume: 197 | Issue: 3 | Pages: 684-688
Object Deep brain stimulation (DBS) is an established neurosurgical technique used to treat a variety of neurological disorders, including Parkinson disease, essential tremor, dystonia, epilepsy, depression, and obsessive-compulsive disorder. This study reports on the use of intraoperative MR imaging during DBS surgery to evaluate acute hemorrhage, intracranial air, brain shift, and accuracy of lead placement. Methods During a 46-month period, 143 patients underwent 152 DBS surgeries including 289 lead placements utilizing intraoperative 1.5-T MR imaging. Imaging was supervised by an MR imaging physicist to maintain the specific absorption rate below the required level of 0.1 W/kg and always included T1 magnetization-prepared rapid gradient echo and T2* gradient echo sequences with selected use of T2 fluid attenuated inversion recovery (FLAIR) and T2 fast spin echo (FSE). Retrospective review of the intraoperative MR imaging examinations was performed to quantify the amount of hemorrhage and the amount of air introduced during the DBS surgery. Results Intraoperative MR imaging revealed 5 subdural hematomas, 3 subarachnoid hemorrhages, and 1 intraparenchymal hemorrhage in 9 of the 143 patients. Only 1 patient experiencing a subarachnoid hemorrhage developed clinically apparent symptoms, which included transient severe headache and mild confusion. Brain shift due to intracranial air was identified in 144 separate instances. Conclusions Intraoperative MR imaging can be safely performed and may assist in demonstrating acute changes involving intracranial hemorrhage and air during DBS surgery. These findings are rarely clinically significant and typically resolve prior to follow-up imaging. Selective use of T2 FLAIR and T2 FSE imaging can confirm the presence of hemorrhage or air and preclude the need for CT examinations.