Abstract BACKGROUND AND IMPORTANCE Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. CLINICAL PRESENTATION An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. CONCLUSION This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent.
Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available
Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
MR Imaging and Cochlear Implants with Retained Internal Magnets: Reducing Artifacts near Highly Inhomogeneous Magnetic Fields
PurposeTo assess risks of RF‐heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil.MethodsSpatial distributions of radio‐frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF‐field measurements were supplemented with direct measurements of RF‐heating of 15 cm long copper wires affixed to and submerged in the “neck” region of the gelled saline‐filled (sodium chloride and polyacrylic acid) “head‐and‐torso” phantom. Temperature elevations at the lead tips were measured using fiber‐optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter.ResultsB1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter — from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm.ConclusionsFor the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF‐heating resulting from the body coil transmit to those associated with using a T/R head coil.
Expanded phenotypes and outcomes among 256
LGI
1/
CASPR
2‐
I
g
G
Annals of Neurology | June 19, 2017 | Volume: 82 | Issue: 1 | Pages: 79-92
Objective To describe an expanded phenotypic spectrum and longitudinal outcome in 256 LGI1‐IgG–seropositive and/or CASPR2‐IgG–seropositive patients. Methods Patients were identified through service neural autoantibody evaluation. Ninety‐five had longitudinal follow‐up (7–456 months; median = 35). Results Among 3,910 patients tested, 196 were LGI1‐IgG positive, 51 were CASPR2‐IgG positive, and 9 were dual positive. Cerebrospinal fluid testing was less sensitive than serum testing, detecting only 24 of 38 (63%) LGI1‐IgG–positive and 5 of 6 (83%) CASPR2‐IgG–positive patients. LGI1‐IgG–positive specimens had higher voltage‐gated potassium channel–IgG immunoprecipitation values (0.33nmol/l, range = 0.02–5.14) than CASPR2‐IgG–positive specimens (0.10nmol/l, range = 0.00–0.45, p < 0.001). Of patients presenting with pain or peripheral nervous system (PNS) manifestations, 39% were LGI1‐IgG seropositive (7% had solely neuropathy or pain). Multivariate analysis identified age as the only significant predictor of central nervous system (CNS) versus PNS involvement (>50 years; odds ratio = 15, p < 0.001). Paroxysmal dizziness spells (PDS), a unique LGI1‐IgG accompaniment (14% of patients), frequently delayed the diagnosis. T2‐mesiotemporal hyperintensity was more common in LGI1‐IgG–positive (41%) than in CASPR2‐IgG–positive patients ( p = 0.033). T1‐bright basal ganglia were confined to LGI1‐IgG–positive patients with faciobrachial–dystonic seizures (9 of 39, 31%). Cancer was found in 44% of LGI1‐IgG/CASPR2‐IgG dual seropositive patients (one‐third thymoma). Response to initial immunotherapy was favorable in 97%; mean modified Rankin score was 3 (range = 1–5) at onset and 1.74 (range = 0–6) at last follow‐up, with 9% having severe refractory disability, 20% being asymptomatic, 28% receiving immunotherapy, and 58% receiving antiepileptic medication. Interpretation Older age is a strong predictor of CNS involvement in patients seropositive for CASPR2‐IgG or LGI1‐IgG. Pain, peripheral manifestations, and stereotypic paroxysmal dizziness spells are common with LGI1‐IgG. Response to initial immunotherapy is often favorable, but some patients remain severely disabled, requiring long‐term immunotherapy and/or antiepileptic medications. Ann Neurol 2017;82:79–92
Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481
BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Magnetic resonance imaging–guided laser interstitial thermal therapy for previously treated hypothalamic hamartomas
OBJECTIVE Hypothalamic hamartomas (HHs) are associated with gelastic seizures and the development of medically refractory epilepsy. Magnetic resonance imaging–guided laser interstitial thermal therapy (MRg-LITT) is a minimally invasive ablative treatment that may have applicability for these deep-seated lesions. Here, the authors describe 3 patients with refractory HHs who they treated with MRg-LITT. METHODS An institutional review board–approved prospective database of patients undergoing Visualase MRg-LITT was retrospectively reviewed. Demographic and historical medical data, including seizure and medication histories, previous surgeries, procedural details, and surgical complications, along with radiological interpretation of the HHs, were recorded. The primary outcome was seizure freedom, and secondary outcomes included medication reduction, seizure frequency, operative morbidity, and clinical outcome at the latest follow-up. RESULTS All 3 patients in the multi-institutional database had developed gelastic seizures related to HH at the ages of 7, 7, and 9 years. They presented for further treatment at 25, 28, and 48 years of age, after previous treatments with stereotactic radiosurgery in all cases and partial hamartoma resection in one case. One ablation was complicated by a small tract hemorrhage, which was stable on postoperative imaging. One patient developed hyponatremia and experienced weight gain, which were respectively managed with fluid restriction and counseling. At the most recent follow-up at a mean of 21 months (range 1–32 months), one patient was seizure free while another had meaningful seizure reduction. Medication was reduced in one case. CONCLUSIONS Adults with gelastic seizures despite previous treatments can undergo MRg-LITT with reasonable safety and efficacy. This novel therapy may provide a minimally invasive alternative for primary and recurrent HH as the technique is refined.
Basal ganglia T1 hyperintensity in LGI1-autoantibody faciobrachial dystonic seizures
Neurology Neuroimmunology & Neuroinflammation | October 2, 2015 | Volume: 2 | Issue: 6 | Pages: No page available
Background Noonan syndrome with multiple lentigines (NSML), formerly known as LEOPARD syndrome, is an autosomal-dominant disorder characterised by lentigines, EKG abnormalities, ocular hypertelorism, pulmonic stenosis, abnormal genitalia, growth retardation and deafness. There is significant clinical overlap between NSML and other disorders that result from dysregulated rat sarcoma/mitogen-activated protein kinase pathway (RASopathies). Except for neurofibromatosis type 1, other RASopathies are not known to be typically associated with neurogenic tumours. Methods and results We evaluated patients from three families with pigmentary skin lesions, progressive neuropathy, enlarged nerves, massive burden of paraspinal tumours (neurofibroma was confirmed in one patient) and a clinical diagnosis of NSML. All patients had a mutation in the protein tyrosine phosphatase catalytic domain of the PTPN11 gene; two unrelated patients had the p.Thr468Met mutation, while the family consisting of two affected individuals harboured the p.Thr279Cys mutation. Molecular analysis performed on hypertrophic nerve tissue did not disclose a second somatic hit in NF1, PTPN11, NF2 or SMARCB1 genes. Conclusions Neurogenic tumours and hypertrophic neuropathy are unusual complications of NSML and may be an under-recognised manifestation that would warrant surveillance. Our observation may also have implications for other disorders caused by RAS-pathway dysregulation.