Abstract In this systematic review, we aimed to assess the sensitivity of serum immunofixation (SIFE), urine immunofixation (UIFE), and serum free light chain (sFLC) in detecting plasma cell dyscrasia associated with light chain (AL) amyloidosis. We searched the literature using PubMed, Embase, and CENTRAL databases since inception through March 2024. We included studies reporting the diagnostic accuracy of immunofixation and/or sFLC in patients with AL amyloidosis. We used the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach to assess the certainty of the evidence and QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) to assess the risk of bias. After deduplication, 29 237 records were screened, and 44 studies (n = 18 071) were included. For the meta-analysis, 28 studies reported sensitivity for SIFE (n = 3390), 24 studies for UIFE (n = 2830), 19 studies for SIFE and UIFE (n = 2819), 21 studies for sFLC ratio (n = 3678), 6 studies for SIFE and sFLC ratio (n = 372), 3 studies for UIFE and sFLC ratio (n = 242), and 10 studies for all 3 tests (n = 1430). Pooled sensitivities were as follows: SIFE, 0.68 (95% confidence interval [CI], 0.62-0.73); UIFE, 0.77 (95% CI, 0.72-0.81); SIFE and UIFE, 0.89 (95% CI, 0.84-0.93); and sFLC ratio, 0.82 (95% CI, 0.78-0.86). When SIFE, UIFE, and sFLC ratio were combined, the sensitivity reached 0.99 (95% CI, 0.96-1.00). The high sensitivity of combining SIFE, UIFE, and sFLC ratio supports their use as a reliable initial testing strategy to raise suspicion for AL amyloidosis and guide decisions regarding future diagnostic modalities.
The role of cardiac imaging for diagnosis of cardiac amyloidosis: a systematic review and meta-analysis of test accuracy
Personalized Acute Upper GI Bleeding Diagnostics for Patients at Highest Risk for Endoscopy: Real-World Experience of a Novel, Binary, Bedside Gastric Blood Detection Device
Journal of Personalized Medicine | November 28, 2025 | Volume: 15 | Issue: 12 | Pages: 573
Background: Upper gastrointestinal bleeding (UGIB) is a common medical emergency associated with significant morbidity, mortality, and healthcare costs. Many patients undergo early endoscopy despite the absence of active bleeding. PillSense is a novel Food and Drug Administration (FDA)-cleared ingestible capsule that rapidly detects the presence of blood in the upper GI tract and may optimize triage decisions. Methods: We conducted a retrospective study evaluating the impact of PillSense on the management of suspected UGIB in an academic center. The primary outcome was the association between capsule results and clinical decision-making, including endoscopy deferral, prioritization, outpatient scheduling, and airway protection. Secondary outcomes included transfusion requirements, time-to-endoscopy, endoscopic intervention, and 30-day adverse events. Results: A total of 28 patients (mean age 64.4 ± 17.9 years, 82.7% male) were included. Compared with negative results, positive results were associated with higher transfusion requirements (median 3 (IQR 3–6) vs. 2 (IQR 1–3.25) units; p = 0.041) and shorter time-to-endoscopy (median 0.2 (IQR 0.01–1) vs. 2 (IQR 1–15.5) days; p = 0.017). In high-risk for sedated endoscopy patients, negative results were associated with EGD deferral in 53.8%, with no subsequent adverse events within 30 days. Endoscopic intervention was performed in 62.5% of positive-result patients versus 9.5% of negative-result patients. Conclusions: The PillSense results were associated with differences in triage and management of high-risk patients with suspected UGIB. Its rapid, accurate, and non-invasive results may reduce unnecessary urgent endoscopy procedures, improve resource utilization, and enhance patient safety, particularly in the highest-risk populations.
Patient Characteristics and Outcomes of Endoscopically Placed Dedicated Transgastric Jejunal Tubes Compared to Percutaneous Endoscopic Gastrostomy With Jejunal Extension Tubes
DEN Open | September 26, 2025 | Volume: 6 | Issue: 1 | Pages: No page available
ABSTRACT Objectives Patients requiring long‐term enteral nutrition or continuous infusion of carbidopa/levodopa can benefit from jejunostomy tube placement. Recently, directly placed percutaneous transgastric jejunal tubes (TGJs) have been used instead of gastrostomy tubes with jejunal extensions (PEG‐Js) for enteral access. We aim to compare patient characteristics and outcomes after placement of TGJs placed via the introducer technique compared to PEG‐Js. Methods We performed a retrospective study of 141 patients (TGJ = 58, PEG‐J = 83) assessed at Mayo Clinic between 2010 and 2024. Patients were identified using a prospectively maintained procedure data registry. Demographic data, patient characteristics, procedural indications, complications, and first‐replacement date were gathered. Statistical analysis included the Wilcoxon rank sum test, chi‐square test, Fisher's exact test, and Kaplan‐Meier estimates. Patients receiving carbidopa/levodopa were excluded from complications analysis due to the carbidopa/levodopa tube's proprietary structure. A p ‐value of <0.05 was set as a threshold for significance. Results Our results demonstrated no difference in cumulative incidence of complications within 1 year for TGJs and PEG‐Js, p ‐value 0.48. Regarding time to first replacement, treating death as a competing risk factor, there was no statistically significant difference in cumulative incidence of replacement within 1 year for TGJs and PEG‐Js, p ‐value 0.389. Conclusions Our study demonstrates that both direct TGJs and PEG‐Js are safe options for long‐term jejunal feeding. More studies are needed to compare endoscopic to radiologically placed percutaneous transgastric jejunal feeding tubes.
Gastrojejunal Anastomosis Adenocarcinoma Occurring After Trans-Oral Revision for Weight Recurrence After Roux-en-Y Gastric Bypass
ACG Case Reports Journal | July 18, 2025 | Volume: 12 | Issue: 7 | Pages: e01775
ABSTRACT Weight recurrence is a late complication after Roux-en-Y gastric bypass. The transoral outlet reduction (TORe) emerged as an endoscopic alternative to revisional surgery for weight recurrence due to a dilated and incompetent gastrojejunal anastomosis. The procedure has been documented as safe and effective in clinical trials and other high-quality medical literature. Several cases of squamous metaplasia of the gastric pouch after repeated TORe procedures using argon plasma coagulation have been reported. We present a case of a late-onset adenocarcinoma of the gastrojejunal anastomosis after a TORe procedure performed using argon plasma coagulation and suturing.
Efficacy and safety of thrombolysis for pediatric venous thromboembolism: a systematic review and meta-analysis
Abstract We conducted this systematic review to evaluate outcomes of thrombolysis followed by anticoagulation vs anticoagulation alone in pediatric patients with venous thromboembolism (VTE). This systematic review addresses mortality, VTE resolution, recurrence, bleeding, and organ-specific outcomes in 5 PICO (population, intervention, comparison, outcomes) questions on thrombolysis across pulmonary embolism (PE), extremity deep vein thrombosis (DVT), right atrial thrombosis (RAT), cerebral sinus venous thrombosis (CSVT), and renal vein thrombosis (RVT). Meta-analysis reported risk ratios or differences (95% confidence intervals [CIs]), and absolute effects per 1000 patients. Certainty of evidence was assessed using GRADE (Grading of recommendation, assessment, Development, and Evaluation) guidelines. Thirteen nonrandomized studies were included and no randomized clinical trials addressed these questions. Thrombolysis might be associated with a higher risk of major bleeding, clinically relevant nonmajor bleeding, or unspecified bleeding with risk differences of 0.09 (95% CI, −0.06 to 0.23), 0.06 (95% CI, −0.11 to 0.22), and 0.09 (95% CI, −0.04 to 0.23), respectively. In PE with hemodynamic compromise, thrombolysis might be associated with a lower risk of mortality but conclusions on PE progression were uncertain in submassive PE. In DVT, thrombolysis may have little to no effect on mortality or thrombus resolution but might be associated with lower risk of postthrombotic syndrome. In RAT, thrombolysis might have little to no effect on thrombus resolution but a higher risk of major bleeding and mortality. For CSVT and RVT, the evidence was very limited. These findings were based on very-low-certainty evidence because of confounding and imprecision from small sample sizes. This systematic review highlights key challenges in developing recommendations for thrombolysis in children with VTE.
Diagnostic Test Accuracy of Bone Scintigraphy in the Diagnosis of Attr Amyloidosis: A Systematic Review and Meta-Analysis
Introduction: For cardiac transthyretin (ATTR) amyloidosis, bone scintigraphy has emerged as a noninvasive diagnostic tool. The use of different tracers, namely Pyrophosphate (PYP), 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD), HydroxymethyleneDiphosphonate (HMDP), allow for the detection of amyloid deposits in the heart. The aim of this systematic review is to evaluate the diagnostic test accuracy of bone scintigraphy in ATTR and light chain (AL) amyloidosis. Methods: As part of the ASH AL Amyloidosis Diagnostic Guideline, we performed systematic reviews for 7 prioritized PICO questions related to the screening, diagnosis and organ involvement evaluation of AL amyloidosis. Electronic searches were conducted on PubMed, Embase, and the Cochrane Central Register of Controlled Trials from inception till January 2024. Two reviewers independently and in duplicate performed title and abstract screening and full text article screening on LASER AI, with conflicts resolved by a third reviewer. Studies were eligible if they included patients that performed both a bone scintigraphy scan and an endomyocardial biopsy for suspicion of ATTR amyloidosis. Test positivity for the visual score was defined to be ≥2, for the heart over contralateral (H/CL) ratio it was > 1.5 at one hour and >1.3 at 3 hours. Diagnostic test accuracy measures of interest were sensitivity, specificity, positive and negative predictive value. Statistical analysis was performed on STATA 18.0. Grading of Recommendations Assessment, Development and Evaluation (GRADE) was used to assess the certainty of evidence. Results: After deduplication, we retrieved 29,237 studies from electronic databases. 12 studies with 1127 patients reported on visual score in patients suspected to have ATTR amyloidosis. The pooled sensitivity for visual score was 96% (95% CI 92.0-98.0) while specificity was 90% (95% CI 84.0-95.0) (Certainty of evidence (COE): Moderate ⨁⨁⨁◯). 3 studies reported on ATTR visual score in combination with evaluating for monoclonal gammopathy, the pooled sensitivity was decreased to 93% (95% CI 65-99) and while specificity increased to 99% (95% CI 80-100) (COE: Moderate ⨁⨁⨁◯). H/CL was evaluated in 5 studies with 189 patients; pooled sensitivity was 97% (95% CI 89.0-99.0) and specificity was 88% (95% CI 64-97) (COE: Low ⨁⨁◯◯). We also performed subgroup analyses for the diagnostic test accuracy of visual score for the different tracers (PYP, DPD, HMDP) in patients suspected to have ATTR amyloidosis. DPD was found to have the highest sensitivity which was found to be 97% (95% CI 91.0-99.0) and a specificity of 95 (95% CI 86.0-98.0) (4 studies, n = 297 COE: Moderate ⨁⨁⨁◯). The sensitivity and specificity for PYP was 95% (95% CI 87.0-98.0) and 90% (95% CI 79.0-96.0) (7 studies, n = 377 COE: Moderate ⨁⨁⨁◯). 1 study reported on HMDP with a sensitivity and specificity of 79% (95% CI 49.0-95.0) and 100% (95% CI 59.0-100.0) (COE: Low ⨁⨁◯◯). Conclusion: Bone scintigraphy has a high sensitivity and specificity for the diagnosis of ATTR amyloidosis, particularly in patients without a monoclonal gammopathy.
Diagnostic Test Accuracy of Cardiac Imaging for AL Amyloidosis: A Systematic Review and Meta-Analysis
Introduction: Although endomyocardial biopsy is the gold standard, echocardiography, and Cardiac Magnetic Resonance (CMR) play a pivotal role in the diagnosis of cardiac amyloidosis. In this systematic review, we aim to estimate the diagnostic test accuracy (DTA) of CMR and echocardiography for cardiac amyloidosis. Methods: As part of the American Society of Hematology guidelines on the diagnosis of Amyloidosis, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials from inception till January 2024 for relevant studies. Two reviewers independently performed title and abstract screening and full-text article screening on LASER Al and extracted relevant data using a piloted Excel sheet. We performed statistical pooling using Stata 18.0 software. We evaluated risk of bias using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and used the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach to assess the certainty of the evidence. We report diagnostic test accuracy as sensitivity (95% confidence interval) and specificity (95% confidence interval). Results: After screening 29,237, we included 9 studies assessing DTA of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) using an endomyocardial biopsy (EMB) as a reference test in patients with amyloidosis (light chain and ATTR). The majority of studies didn't report on the type of amyloidosis where only 2 out of 9 were in patients with light chain amyloidosis. The pooled estimates for sensitivity and specificity of LGE are 0.95 (0.88. 0.98), and 0.81 (0.60, 0.92), respectively. We did a sensitivity analysis and included only LGE suggestive for amyloidosis which didn't change sensitivity but led to an increase in specificity for amyloidosis to 0.87 (0.76, 0.94), respectively. The pooled estimates were based on moderate certainty in the evidence. For 2-dimensional echocardiography, we addressed DTA for different echocardiographic findings and we did not limit the reference to EMB. A panel of experts judged whether the reference was acceptable or not. Acceptable reference was EMB alone or a combination of extracardiac biopsy plus cardiac imaging (CMR or echocardiography) with or without positive cardiac biomarkers (troponin or BNP or NT-proBNP). Six studies (n=2063) addressed interventricular septum thickness (IVS), sensitivity was 0.77 (0.69, 0.84) and specificity was 0.71 (0.60, 0.81). 4 out of 6 studies used 12 mm as a cutoff while the other 2 studies used 13 mm as a cutoff. Only 2 studies (n=1667) assessed the DTA of posterior wall thickness (PWT), with sensitivity ranging from 0.76 to 1.00, and specificity ranging from 0.84 to 0.89. Six studies (n=438) addressed diastolic dysfunction (grade 2,3), with a sensitivity of 0.71 (0.40, 0.90), and specificity of 0.75 (0.64, 0.84). 7 studies (n=472) reported DTA of only diastolic dysfunction grade 3. When compared to diastolic dysfunction (grade 2,3, sensitivity decreases to 0.42 (0 28. 0.58) and specificity increases to 0.89 (0.83. 0.94). For E/A ratio, only 2 studies (n=127) were included. Sensitivity ranged from 0.45 to 0.65, and specificity ranged from 0.85 to 0.98. Four studies (n=1596) yielded a sensitivity of 0.86 (0.65, 0.95) and specificity of 0.76 (0.55, 0.89) of left ventricular global longitudinal strain (GLS). All except one used -17% as a cutoff for GLS. For apical sparing on GLS, pooled estimates from 8 studies (n=2253) led to a sensitivity of 0.72 (0.64, 0.78) and specificity of 0.78 (0.64, 0.88). There was a variation of cutoff across studies. The certainty of evidence for echocardiographic findings was low to moderate. Conclusion: CMR is a more accurate test with better performance compared to echocardiography.
Diagnostic Test Accuracy of Serum and Urine Immunofixation and Free Light Chains in the Diagnosis of Light Chain Amyloidosis: A Systematic Review and Meta-Analysis
Introduction: Light-chain (AL) amyloidosis is caused by the secretion of immunoglobulin light chains by monoclonal plasma cells. The increase in the levels of these monoclonal proteins may proceed the development of any clinical symptoms, and their identification in the serum and urine remains an integral part of establishing a diagnosis of AL amyloidosis. This systematic review aims to evaluate the diagnostic test accuracy of serum immunofixation (SIFE), urine immunofixation (UIFE), and free light chain (FLC) ratio for the diagnosis of AL amyloidosis. Methods: As part of the ASH AL Amyloidosis Diagnostic Guideline, we performed systematic reviews for 7 prioritized PICO questions related to the screening, diagnosis and organ involvement evaluation of AL amyloidosis. Electronic searches were conducted on PubMed, Embase, and the Cochrane Central Register of Controlled Trials from inception till January 2024. Two reviewers independently and in duplicate performed title and abstract screening and full text article screening on LASER AI, with conflicts resolved by a third reviewer. Eligible studies were those that included patients who performed one of the three tests (SIFE, UIFE, and κ/λ FLC) and had their AL amyloidosis diagnosis confirmed via a biopsy. Diagnostic test accuracy measures of interest were sensitivity, specificity, positive and negative predictive value. Statistical analysis was performed on OpenMeta[Analyst]. Grading of Recommendations Assessment, Development and Evaluation (GRADE) was used to assess the certainty of evidence. Results: After deduplication, we retrieved 29,237 studies from electronic databases. 31 studies with 3973 patients reported on the use of serum immunofixation (SIFE) with a pooled sensitivity of 72.4% (95% CI 68.1%-76.4%). 27 studies with 2855 patients reported on the use of urine immunofixation UIFE for the diagnosis of AL amyloidosis with a pooled sensitivity of 78.6% (95% CI 74.6%-82%). 29 studies with 5305 patients reported on the use of κ/λ FLC ratio amyloidosis with a pooled sensitivity of 79.9% (95% CI 73.7%-84.9%). 24 studies reported on the use of both SIFE and UIFE with a sample size of 3751 patients and a pooled sensitivity of 90% (95% CI 85.3%-93.3%). 3 studies reported on the use SIFE and κ/λ FLC ratio with 321 patients and a pooled sensitivity of 97.7% (95% CI 95.6%-99.9%). Finally, we identified 10 studies that performed SIFE,UIFE, and κ/λ FLC ratio concurrently with 1926 patients and a pooled sensitivity of 99% (95% CI 97%-99.7%) of all three tests and considering a result abnormal if any of the components had a positive result. We also identified 5 studies with 957 patients reporting on the concurrent use of SIFE, UIFE, and κ/λ FLC ratio for the diagnosis AL amyloidosis and differentiation of AL from ATTR amyloidosis in a population of patients with suspected cardiac amyloid involvement, the pooled sensitivity was found to be 99%(95% CI 99%-100%) and with a pooled specificity of 77%(95% CI 75%-80%). Certainty of evidence moderate for all outcomes. Conclusion: The combined use of SIFE, UIFE, and κ/λ FLC ratio has a high sensitivity for the diagnosis of AL amyloidosis, and the tests remain a valuable initial screening of AL amyloidosis and differentiation from ATTR amyloidosis.