Citations 4

Deep Brain Stimulation: Past, Present, and Future

IEEE Transactions on Biomedical Engineering | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: 1-16

10.1109/tbme.2026.3686882 | PMID 42024924

Haemostatic Prophylaxis and Colonoscopy Outcomes in Patients With Bleeding Disorders: An Update

Haemophilia | December 17, 2025 | Volume: 32 | Issue: 1 | Pages: 348-352

10.1111/hae.70188 | PMID 41403337

Outcomes in Patients With Mitral Annular Disjunction and an Implantable‐Cardioverter Defibrillator

Journal of Cardiovascular Electrophysiology | March 18, 2025 | Volume: 36 | Issue: 5 | Pages: 1014-1021

10.1111/jce.16612 | PMID 40098314

ABSTRACT Background Mitral annular disjunction (MAD) carries an increased risk of complex ventricular arrhythmias, which can lead to sudden cardiac death. Many of these patients undergo implantable cardioverter defibrillator (ICD) implantation, but their ICD outcomes are not known. Objective The aim of this study was to assess the outcomes of ICD implantation and the predictors of appropriate ICD therapies in patients with MAD. Methods The study included patients with MAD who underwent ICD implantation. Clinical, electrocardiographic, cardiac imaging, and device therapy data were collected. Results Forty‐nine patients with MAD and ICD were included. Median age was 49 (21) years, and 29 (59%) were female. 13 (27%) patients underwent ICD implantation for primary prevention and 36 (73%) patients for secondary prevention. Over a median follow‐up of 27.3 (35.3) months, 23 (47%) patients received ICD therapies. 18 (37%) patients had appropriate ICD therapies, and 5 (10%) patients had inappropriate ICD shocks. Median time to first appropriate therapy was 22.3 (63.3) months. In patients with a secondary prevention ICD indication, the rate of appropriate ICD therapies was 44%, while in patients with a primary prevention ICD indication, it was 15%. Among patients with appropriate ICD therapies, the first therapies were delivered for monomorphic ventricular tachycardia (VT) in 7 (39%) patients and polymorphic VT or ventricular fibrillation (VF) in 11 (61%) patients. Patients with appropriate ICD therapies were more likely to have a history of SCA ( p = 0.003) and/or low left ventricular ejection fraction (LVEF) ( p = 0.022) before ICD implantation as compared to patients without appropriate ICD therapies. Conclusions In our cohort of patients with MAD and ICD, appropriate ICD therapies were common. Most appropriate ICD therapies were delivered for polymorphic VT or VF. Larger studies are needed to elucidate the mechanisms of VAs and refine risk stratification in MAD.
Clinical Evaluation of the NaviNetics Stereotactic System Using Intraoperative Portable Surgical Imaging System in DBS Surgery

Operative Neurosurgery | November 18, 2024 | Volume: 29 | Issue: 1 | Pages: 93-101

10.1227/ons.0000000000001427 | PMID 39883866

BACKGROUND AND OBJECTIVES: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation. In this article, we aim to evaluate the compatibility of the stereotactic frame system with the intraoperative O-arm system regarding lead accuracy and surgical flow. METHODS: A total of 17 patients undergoing DBS surgery for movement disorders were evaluated. One patient underwent both the stereotactic CT and O-arm localization, while 16 patients underwent only intraoperative O-arm localization. Following lead placement, intraoperative O-arm imaging was obtained to evaluate the accuracy of the lead placement. Accuracy was defined as the error measured as the distance from the center of the planned trajectory to the cannula. RESULTS: Less than 0.1 mm difference was found between the O-arm imaging technique and CT image localization of the NaviNetics stereotactic head frame in DBS surgery. Of the 16 patients who underwent the intraoperative O-arm imaging alone, the targets included bilateral ventral intermediate nucleus (16 leads), bilateral globus pallidus internus (4 leads), and subthalamic nucleus (12 leads). The mean ± SD radial error in the probe's eye view was 0.71 ± 0.33 mm for n = 32 leads. No tract hemorrhage was observed. CONCLUSION: Intraoperative O-arm imaging can be used safely and effectively for stereotactic registration and lead placement confirmation with the stereotactic system in both awake and asleep DBS surgery.