Abstract Background Measurement of cholesterol within lipoprotein subfractions may aid in cardiovascular disease prediction. Simple, homogenous enzymatic assays for the direct measurement of lipoprotein subfractions have been developed to measure small dense low-density lipoprotein cholesterol (sdLDL-C), high-density lipoprotein-3 cholesterol (HDL3-C), and triglyceride-rich lipoprotein (TRL-C) cholesterol. The objective of this study was to determine biological variability for sdLDL-C, HDL3-C, and TRL-C in a healthy reference population to facilitate interpretation of these analytes. Methods Serum samples were collected from 24 healthy subjects (n = 14 female/10 male) daily for 3 days while non-fasting, and daily for 5 days, weekly for 4 weeks, and monthly for 6 months after overnight fasting. sdLDL-C, HDL3-C, and TRL-C cholesterol were measured by homogenous enzymatic assays. Sources of variability (between-subject, within-subject, and analytical) were calculated using random-effects regression models. Reference change value (RCV) and index of individuality (II) for each time period were determined from the variance components. Results Analytic variability (daily, weekly, and monthly CVA) was <3% for each analyte. Monthly within-subject variability (CVI) was 17.1% for sdLDL-C, 7.4% for HDL3-C, and 25.7% for TRL-C. Most of the monthly variation was attributed to between-subject variation for all 3 analytes. Overall RCVs for monthly measurements were 18.1 mg/dL for sdLDL-C, 6.1 mg/dL for HDL3-C, and 16.0 mg/dL for TRL-C. IIs were <0.6 for sdLDL-C and HDL3-C, and 0.81 for TRL-C. Conclusions sdLDL-C, HDL3-C, and TRL-C showed moderate within-subject variability, but high between-subject variability, in a healthy reference population. Given the high individuality of each analyte, population-based reference intervals may be inadequate to detect clinically significant changes.
Corrigendum to: Comparison of Five Common Analyzers in the Measurement of Chemistry Analytes in an Authentic Cohort of Body Fluid Specimens
American Journal of Clinical Pathology | March 17, 2022 | Volume: 158 | Issue: 1 | Pages: 157-157
AbstractBackgroundCeramides are bioactive lipid species that mediate numerous cell-signaling events. Elevated plasma ceramides concentration constitutes a risk factor for several pathologies. Multiple studies have affirmed the plasma concentrations of 4 specific ceramides (Cer16:0, Cer18:0, Cer24:0, and Cer24:1) can predict cardiovascular disease risk. Furthermore, these ceramides can be altered by many lipid-lowering therapies. Understanding the biological variability within an individual, and within a population, will further inform the clinical use of plasma ceramides as a biomarker. In this study, we aimed to define the intra- and interbiological variability of ceramides in a healthy reference population in a weekly and monthly manner.MethodsFasting plasma from 24 healthy adults was collected daily (5 days), weekly (4 weeks), and monthly (7 months). Ceramide concentrations were measured with liquid chromatography–mass spectrometry (LC–MS). For analysis, we used random-effects regression models to estimate variance components.ResultsThe analytical variability was smaller compared to the biological variability overall. The greatest variation reported was between-subject variation for all ceramide species. The critical difference-reference change value (RCV) for within-subject variations monthly were 0.07 mcmol/L (Cer16:0), 0.04 mcmol/L (Cer18:0), 1.09 mcmol/L (Cer24:0), and 0.27 mcmol/L (Cer24:1). The index of individuality (IOI) of ceramides were 0.82 (Cer16:0), 0.96 (Cer18:0), 1.06 (Cer24:0), and 0.89 (Cer24:1). The most consistent ceramide species was Cer18:0 with the lowest within- and between-subject critical differences in weekly and monthly measurements.ConclusionsOverall, this study demonstrates that the variability of ceramide concentrations at different time points is minimal within individuals, allowing a single draw to be sufficient at least in a yearly time frame.
Comparison of Five Common Analyzers in the Measurement of Chemistry Analytes in an Authentic Cohort of Body Fluid Specimens
American Journal of Clinical Pathology | December 6, 2021 | Volume: 158 | Issue: 1 | Pages: 47-61
Abstract Objectives Interpretation of body fluid (BF) results is based on published studies and clinical guidelines. The aim of this study is to determine whether the assays from five common commercial vendors produce similar results in BFs for 12 analytes in a BF cohort. Methods BFs (n = 25) and serum (n = 5) were analyzed on five instruments (Roche cobas c501, Ortho 5600, Beckman AU5800 and DXI800, Siemens Vista 1500, and Abbott Architect c8000) to measure albumin, amylase, total bilirubin, cholesterol, creatinine, glucose, lactate dehydrogenase (LDH), lipase, total protein, triglycerides, urea nitrogen, and carcinoembryonic antigen. Deming regression and Bland-Altman analysis were used for method comparison to Roche. Results Results were significantly different from Roche for LDH and lipase on Ortho and lipase on Siemens but similar for both BFs and serum. BF differences were larger than serum differences when measuring creatinine, glucose, and urea nitrogen on Ortho and glucose on Siemens. Conclusions Five instruments used to perform BF testing produce results that are not significantly different except for lipase and LDH measurements. Bias of similar magnitude observed in both BF and serum should not affect interpretation. Further investigations into Ortho and Siemens measuring glucose and Ortho measuring creatinine and urea nitrogen are warranted.
Investigation of the correlation between immature reticulocyte fraction and reticulocyte hemoglobin content with common tests for iron deficiency anemia
American Journal of Clinical Pathology | October 31, 2021 | Volume: 156 | Issue: Supplement_1 | Pages: S12-S13
Abstract Reticulocyte hemoglobin content (Ret-He, the hemoglobin within reticulocytes or immature red blood cells) and immature reticulocyte fraction (IRF, the immature fraction of the absolute-reticulocyte-count) are tests that provide insight into erythropoiesis and iron status earlier than conventional iron studies offering the added benefit of not being acute-phase-reactants. Studies have shown that Ret-He is a diagnostic marker for iron-deficiency-anemia (IDA), but fewer studies have investigated IRF. Our laboratory is currently planning to report these parameters when reticulocyte is ordered. Since these are new parameters, we wanted to investigate their overall correlation with complete blood count (CBC) and other iron studies to gain a better appreciation of their utility in our patient population. The aim of this study was to compare the overall correlation of Ret-He and IRF with seven tests used in the evaluation of IDA. To our knowledge these parameters have not all been directly correlated within a single study. CBC and reticulocytes were quantified using XN 9000 hematology analyzers (Sysmex Corporation), ferritin (DXI 800, Beckman Coulter Inc.), and % iron-saturation (measured using total iron-binding-capacity (TIBC)=transferrin*1.18 on Cobas 6000, Roche Diagnostics). Two de-identified cohorts of patients undergoing physician-ordered reticulocyte testing were used for this analysis. Dataset 1 (DS1): (N=2026 from Mayo Clinic Florida) had Ret-He and IRF compared to absolute-reticulocyte-count (Ret), ferritin and % iron saturation. Dataset 2 (DS2): (N=3990 from Mayo Clinic Rochester) had Ret-He and IRF compared to the red-cell-indices of the CBC including hemoglobin (Hgb), mean-corpuscular-volume (MCV), mean-corpuscular-hemoglobin (MCH), and mean-corpuscular-hemoglobin-concentration (MCHC). Correlation coefficients were calculated using Spearman rank-order (ρ) wherein values below +/-0.39 are weak, between +/-0.40-0.59 are considered moderate, and values above +/-0.60 are considered strong. For DS1, Ret-He demonstrated the following correlations: Ret (ρ=0.01), ferritin (ρ=0.33), % iron saturation (ρ=0.63). IRF demonstrated: Ret (ρ=0.46), ferritin (ρ=-0.05), % iron saturation (ρ=-0.22). For DS2, Ret-He demonstrated the following correlations: Hgb (ρ=0.17), MCV (ρ=0.64), MCH (ρ=0.74), MCHC (ρ=0.56). IRF demonstrated Hgb (ρ=-0.41), MCV (ρ=0.10), MCH (ρ=0.04), MCHC (ρ=-0.11). Ret-He and IRF demonstrated different correlative profiles suggesting they may have differing uses. Ret-He was strongly positively-correlated with % iron saturation, MCV, MCH and moderately positively-correlated with MCHC. These positive-correlations are consistent with relationships established in the literature. Interestingly, Ret-He was only weakly correlated with ferritin, possibly owing to ferritin being an acute-phase-reactant. IRF had a moderate positive correlation with Ret and moderate inverse correlation with Hgb. Both of these IRF relationships are consistent with other reports, but both relationships have not been shown in the same study before, preventing direct comparison until now. The literature suggests IRF may have more potential in monitoring treatment than in diagnosis. One limitation of these datasets is their lack of clinical correlation such as established iron-deficiency, anemia status, or treatment information.
Biological Variability of Small Dense LDL, HDL3, and Triglyceride-Rich Lipoprotein Cholesterol
American Journal of Clinical Pathology | October 31, 2021 | Volume: 156 | Issue: Supplement_1 | Pages: S4-S4
Abstract The guideline-recommended lipid panel for cardiovascular disease (CVD) risk assessment measures total cholesterol, high-density lipoprotein (HDL) cholesterol, triglycerides, and calculated low-density lipoprotein (LDL) cholesterol. Measured cholesterol in subfractions of HDL and LDL purportedly improve CVD risk prediction. Homogenous enzymatic methods are now available for measurement of the cholesterol within small dense LDL (sLDL), small dense HDL (HDL3), and triglyceride-rich lipoproteins (TRL). For meaningful interpretation of these measurements, an understanding of the potential sources and extent of result variability is needed. The smallest difference between serial measurements within a patient that likely reflects a change in clinical status is called the reference change value (RCV). Biological variability and reference change values (RCV) are well-characterized for basic lipids but there is limited information for sLDL, HDL3 or TRL. The objective of this study was to determine intra- and inter-individual variability for sLDL, HDL3, and TRL in a healthy reference population. Serum samples were collected from 24 healthy subjects (n=14 female/10 male) daily for three days (non-fasting), daily for five days (fasting), weekly for four weeks (fasting), and monthly for 7 months (fasting). sLDL, HDL3, and TRL cholesterol were measured in duplicate by enzymatic colorimetric assays (Denka, Japan) on a Roche Cobas c501. Each source of variability (between subject, within subject, and analytical) was calculated using random-effects regression models to estimate each variance component including the overall variation, standard deviation (SD), coefficient of variation (CV), and proportion of total variance (between-subject, within-subject, and analytical). Using these analytical and biological variances, the reference change value (RCV), index of individuality (IoI), and intraclass correlation coefficient (ICC) were determined. Analytic variability (CVa) from monthly testing was 1.2%, 1.1%, and 1.5% for sLDL, HDL3, and TRL, respectively. Monthly within-subject variability (CVw) was 17.1% for sLDL, 7.4% for HDL3 and 25.7% for TRL. Monthly between-subject variability (CVb) was 32.2%, 13.93%, and 33.4% for sLDL, HDL3, and TRL, respectively. Most of the monthly variation was attributed to between-subject variation for all three tests. Within-subject variation accounted for 37% of TRL variation and 22% for both sLDL and HLD3. Within-subject RCVs for monthly measurements were 16.9mg/dL for sLDL, 5.3mg/dL for HDL3, and 15.1mg/dL for TRL. IoIs for monthly testing were 0.81 for TRL, 0.57 for sLDL, and 0.61 for HDL3. Our data demonstrate that sLDL, HDL3, and TRL show low analytical variability, moderate within-subject variability, but high between-subject variability when measured by homogenous assays in a healthy population. The IoI value (>0.6) for TRL suggests use of a reference interval is appropriate for result interpretation. Conversely, clinical cut-points may be more useful than reference intervals for sLDL and HDL3 which had IoIs ~0.6. These findings may be useful for clinical interpretation, particularly when comparing successive measurements of these analytes.
Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis
The Bone & Joint Journal | June 1, 2021 | Volume: 103-B | Issue: 6 | Pages: 1119-1126
Aims The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126.
Effect of pH on the Quantification of Common Chemistry Analytes in Body Fluid Specimens Using the Roche cobas Analyzer for Clinical Diagnostic Testing
American Journal of Clinical Pathology | March 10, 2021 | Volume: 156 | Issue: 5 | Pages: 722-727
Abstract Objectives To determine the influence of pH on recovery of analytes in body fluids (BFs), investigate the mechanism of pH interference, measure the frequency of abnormal-pH BFs received, and compare pH measured by meter and paper. Methods We performed pH titration in residual BFs. A low-pH BF was spiked and neutralized to investigate pH interference. We measured analytes on a Roche cobas c501 analyzer (Roche Diagnostics) and calculated the percent recovery. Measurement of pH using a meter and paper was conducted on 122 BF samples received in the laboratory. Results Enzyme activity in BFs was unaffected when pH = 7.4-8.5 lactate dehydrogenase, pH = 7.3-10.2 amylase, pH = 6.0-9.9 lipase, and pH = 1.3-11.7 all other analytes. BFs had mean (range) pH of 8.0 (5.1-8.9), with a mean (range) difference (paper ‒ meter) of ‒0.4 (‒0.6 to 1.1). Conclusions Irreversible loss of enzyme activity occurs in BFs at low pH. Few clinical BFs have pH < 7.0, but laboratories should incorporate pH measurement in BF workflows.
Comparative analysis of 23 synovial fluid biomarkers for hip and knee periprosthetic joint infection detection
Journal of Orthopaedic Research | June 2, 2020 | Volume: 38 | Issue: 12 | Pages: 2664-2674
AbstractThere is interest in novel synovial fluid biomarkers for the detection of periprosthetic joint infection (PJI). Here, we assessed the diagnostic accuracy of 23 simple or sophisticated synovial fluid biomarkers for periprosthetic hip or knee infection detection. One hundred seven subjects were studied, 57 of whom had aseptic failure (AF) and 50 PJI. The following synovial fluid biomarkers were tested using spectrophotometric assays, immunoassays, lateral flow tests, or test strips: leukocyte count, monocyte percentage, lymphocyte percentage, neutrophil percentage, C‐reactive protein (CRP), glucose, lactate, granulocyte‐macrophage colony‐stimulating factor, interferon‐γ, interleukin‐1β (IL‐1β), IL‐2, IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, IL‐17A, IL‐23, tumor necrosis factor‐α, α‐defensin, and leukocyte esterase. The best‐performing synovial fluid biomarkers to differentiate PJI from AF—that is, those with highest area under the curve compared to all other biomarkers—were leukocyte count, percent neutrophils and percent monocytes, CRP, and α‐defensin (P < .0001).
Proposed Plasma Ammonia Reference Intervals in a Reference Group of Hospitalized Term and Preterm Neonates
The Journal of Applied Laboratory Medicine | January 27, 2020 | Volume: 5 | Issue: 2 | Pages: 363-369
AbstractBackgroundPlasma ammonia is commonly measured in the diagnostic evaluation of hospitalized newborns, but reference values are not well defined.MethodsWe prospectively enrolled newborns admitted to the level III/IV neonatal intensive care unit and level II intermediate special care nursery from January 2017 to January 2018. Infants with inborn errors of metabolism or liver disease were excluded. Plasma ammonia concentrations were measured once within the first week of life and evaluated by sex, gestational age, timing of the draw, blood collection method, and type of nutrition. Reference intervals were calculated.Results127 neonates were included; one third (34%) were term infants born at ≥37 weeks gestation, and two thirds (66%) were born preterm at <37 weeks gestation. Median plasma ammonia concentrations were 32 μmol/L (range <10 to 86 μmol/L). Median ammonia concentrations were higher among preterm compared to term infants (35 vs. 28 μmol/L, p = 0.0119), and term female compared to term male infants (34 vs. 26 μmol/L, p = 0.0228). There was no difference in median ammonia concentrations between female and male preterm infants, based on gestational age within the preterm group, timing of the blood draw, presence of hyperbilirubinemia, blood collection method, or type of nutritional intake.ConclusionsPlasma ammonia concentrations among newborns are higher than the expected adult concentrations and may vary by gestational age and sex. Blood collection method, type of nutrition, hyperbilirubinemia, and timing of the draw do not impact concentrations. We propose a reference limit of ≤82 μmol/L for newborns less than one week of age.