Citations 9

Amyloid PET Quantitation and Centiloid Thresholds in the Diagnosis of Alzheimer Disease

JAMA | July 13, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1001/jama.2026.13116 | PMID 42441390

Importance Amyloid positron emission tomography (PET) is increasingly used in research and clinical settings to determine the etiology of cognitive decline and eligibility for amyloid-targeting therapies. To assist with amyloid PET evaluation and to guide clinical decision-making, images can be quantified in a standardized unit called Centiloid, the interpretation of which can vary according to the method and threshold used. Objective To collect Centiloid values from available studies and determine robust positivity cutoffs using data-driven methods and correspondence with visual reads. Data Sources PubMed search (October 2024) identified studies with Centiloid values. Corresponding authors were invited to share individual participant data. Additional data were obtained through access-controlled repositories and conference outreach (July 2024-July 2025). Study Selection Studies were included if they provided Centiloids, radiotracer, age, and sex. Data Extraction and Synthesis Each study was analyzed using a unified statistical pipeline; study estimates were pooled using random-effects meta-analysis. Main Outcomes and Measures Gaussian mixture models (GMMs) were fitted to Centiloid values for each study. In studies with a bimodal distribution (per integrated completed likelihood), single cutoffs for positivity were set as mean plus 2 SDs of the lower gaussian component. Using GMMs, a double-cutoff approach defined a lower certainty range using a 90% posterior probability cutoff for assignment to the low (amyloid-negative) vs high (amyloid-positive) component. An alternative Centiloid cutoff was derived from maximizing the correspondence (Cohen κ) with the binary visual reads when available. Results This meta-analysis included cross-sectional amyloid PET scans acquired with 5 radiotracers from 49 227 participants across 53 studies from 15 countries (mean age, 71 years; 54% female, 62% cognitively impaired). The data-driven GMM approach identified a bimodal distribution in 51 studies (n = 48 786), resulting in a single cutoff for positivity of 18 Centiloids (95% CI,16-19; I 2 = 97%). The double-cutoff approach revealed high confidence for interpreting scans as negative when Centiloid values were lower than 11 (95% CI, 9-13; I 2 = 95%) and interpreting scans as positive if Centiloid values were higher than 26 (95% CI, 24-28; I 2 = 95%). In analyses of correspondence with binary (positive or negative) visual reads of amyloid PET scans (n = 35 045; 36 studies), Centiloids were highly predictive of visual positivity (Cohen κ, 0.86; 95% CI, 0.83-0.89; I 2 = 96%) with a cutoff of 27 Centiloids (95% CI, 24-30; I 2 = 80%). Conclusions and Relevance In this individual participant data meta-analysis, positivity cutoffs converged around 18 Centiloids (data-driven) and 27 Centiloids (visual reads). Findings from a double-cutoff analysis suggest that scans in the 11 to 26 Centiloid range should be interpreted with caution depending on the context of use.
Every Centiloid, from Everywhere, All at Once

Alzheimer's & Dementia | January 9, 2026 | Volume: 21 | Issue: S2 | Pages: No page available

10.1002/alz70856_107124

Abstract Background Ten years after the original publication, the Centiloid framework is now broadly used to harmonize amyloid‐PET quantification, facilitate data sharing and comparison across cohorts, and even assist visual interpretation in clinical settings. We evaluated the global implementation of Centiloids by comparing their distribution and corresponding positivity thresholds across cohorts. Methods We gathered data from publicly available cohorts and reached out to investigators across the world to collect cross‐sectional Centiloids, demographic and clinical information, and visual read data. Gaussian mixture models (GMM, k=2) were fitted to Centiloid values for each cohort and cutoffs were calculated as mean + 2SD of the lower Gaussian. When visual reads were available, we determined Centiloid cutoffs that maximized correspondence with visual reads (Cohen's kappa). Data was combined across cohorts using random effects meta‐analyses. Results As of January 2025, we included 37 cohorts ( n = 41,678 participants) with heterogeneous pipelines, radiotracers, and clinical and demographic characteristics (Table‐1). The low Gaussian peaks ranged from ‐9 to 10CL; the meta‐analysis identified a common peak at 1CL. The second peaks were more heterogeneous (range=38‐102CL; meta‐analysis outcome=64CL). Across cohorts, the proportion of cognitively unimpaired versus impaired participants impacted the position of both peaks, with better separation in cohorts enriched in impaired individuals (Figure 1C). The meta‐analysis indicated a GMM‐based cutoff of 19CL (95%CI: 16‐21CL, Figure 1B); subgroup analyses showed no evidence of significant effect between single versus multicenter settings (17 versus 20CL, p = 0.30), MRI‐based or PET‐only processing (18 versus 19CL, p = 0.88), and no evidence of difference across radiotracers (Flutemetamol: 16CL; PIB: 17CL, Flutafuranol: 18CL, Florbetaben: 19CL, Florbetapir: 20CL, p = 0.78). In a subset of 29,496 participants with visual reads available, binary visual reads corresponded well to Centiloids (common kappa=0.86, Figure 2A). The visual read‐based cutoff of 24CL (95%CI: 21‐27CL, Figure 2B) maximized correspondence between visual read and quantification and was slightly higher than the GMM‐based cutoff. All meta‐analysis models showed high non‐random heterogeneity (I 2 >80%) across studies, suggesting non‐random differences in peaks and cutoffs. Conclusions Meta‐analysis‐based cutoffs align well with thresholds from the existing literature. High heterogeneity among studies underscores the need to investigate contributing factors, raising concerns about applying common cutoffs.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units

Alzheimer's & Dementia | January 8, 2026 | Volume: 21 | Issue: S2 | Pages: No page available

10.1002/alz70856_106362

Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [ 18 F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [ 18 F]flortaucipir (ADNI), [ 18 F]MK‐6240 (CPAS), and [ 18 F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([ 18 F]flortaucipir) and AIBL ([ 18 F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [ 18 F]flortaucipir and [ 18 F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([ 18 F]PI‐2620) are underway.
Every Centiloid, from Everywhere, All at Once

Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available

10.1002/alz70862_110011

Abstract Background Ten years after the original publication, the Centiloid framework is now broadly used to harmonize amyloid‐PET quantification, facilitate data sharing and comparison across cohorts, and even assist visual interpretation in clinical settings. We evaluated the global implementation of Centiloids by comparing their distribution and corresponding positivity thresholds across cohorts. Methods We gathered data from publicly available cohorts and reached out to investigators across the world to collect cross‐sectional Centiloids, demographic and clinical information, and visual read data. Gaussian mixture models (GMM, k=2) were fitted to Centiloid values for each cohort and cutoffs were calculated as mean + 2SD of the lower Gaussian. When visual reads were available, we determined Centiloid cutoffs that maximized correspondence with visual reads (Cohen’s kappa). Data was combined across cohorts using random effects meta‐analyses. Results As of January 2025, we included 37 cohorts ( n = 41,678 participants) with heterogeneous pipelines, radiotracers, and clinical and demographic characteristics (Table‐1). The low Gaussian peaks ranged from ‐9 to 10CL; the meta‐analysis identified a common peak at 1CL. The second peaks were more heterogeneous (range=38‐102CL; meta‐analysis outcome=64CL). Across cohorts, the proportion of cognitively unimpaired versus impaired participants impacted the position of both peaks, with better separation in cohorts enriched in impaired individuals (Figure‐1C). The meta‐analysis indicated a GMM‐based cutoff of 19CL (95%CI: 16‐21CL, Figure‐1B); subgroup analyses showed no evidence of significant effect between single versus multicenter settings (17 versus 20CL, p = 0.30), MRI‐based or PET‐only processing (18 versus 19CL, p = 0.88), and no evidence of difference across radiotracers (Flutemetamol: 16CL; PIB: 17CL, Flutafuranol: 18CL, Florbetaben: 19CL, Florbetapir: 20CL, p = 0.78). In a subset of 29,496 participants with visual reads available, binary visual reads corresponded well to Centiloids (common kappa=0.86, Figure‐2A). The visual read‐based cutoff of 24CL (95%CI: 21‐27CL, Figure‐2B) maximized correspondence between visual read and quantification and was slightly higher than the GMM‐based cutoff. All meta‐analysis models showed high non‐random heterogeneity (I 2 >80%) across studies, suggesting non‐random differences in peaks and cutoffs. Conclusions Meta‐analysis‐based cutoffs align well with thresholds from the existing literature. High heterogeneity among studies underscores the need to investigate contributing factors, raising concerns about applying common cutoffs.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units

Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available

10.1002/alz70862_109722

Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [¹⁸F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [¹⁸F]flortaucipir (ADNI), [¹⁸F]MK‐6240 (CPAS), and [¹⁸F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([¹⁸F]flortaucipir) and AIBL ([¹⁸F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [¹⁸F]flortaucipir and [¹⁸F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([¹⁸F]PI‐2620) are underway.
Plasma Phosphorylated Tau 217 to Identify Preclinical Alzheimer Disease

JAMA Neurology | September 15, 2025 | Volume: 82 | Issue: 11 | Pages: 1122

10.1001/jamaneurol.2025.3217 | PMID 40952756

Importance Advances in Alzheimer disease (AD) have shifted research focus to earlier disease stages, necessitating more scalable approaches to identify cognitively unimpaired individuals with amyloid β (Aβ) pathology. Objective To assess the utility of plasma phosphorylated tau 217 (p-tau217) for classifying Aβ status in cognitively unimpaired individuals, both as a stand-alone test and in a 2-step approach where positive plasma results were confirmed using a second modality (Aβ positron emission tomography [PET] or cerebrospinal fluid [CSF]). Design, Setting, and Participants This cross-sectional cohort study used data collected between June 2009 and March 2024. We included 2916 cognitively unimpaired participants from 12 international independent observational cohorts in the US, Europe, Australia, and Canada with available plasma p-tau217 levels and CSF or PET Aβ biomarkers. Performance comparisons between mass spectrometry and immunoassay-based p-tau217 measurements were also performed (n = 964). Exposures Plasma p-tau217 levels measured by immunoassay. Main Outcome and Measures Aβ status, determined by CSF or Aβ PET biomarkers. Results Participants had a mean (SD) age of 66.9 (9.9) years; 971 (33.3%) were Aβ positive by either CSF or PET, 1667 (57.2%) were women, and 1108 (38.1%) carried at least 1 APOE ε4 allele. As a stand-alone test, plasma p-tau217 achieved a positive predictive value (PPV) of 79% (95% CI, 74-84) and an overall accuracy of 81% (95% CI, 80-82). In a 2-step workflow, the PPV and accuracy significantly increased to 91% (95% CI, 86-95). While this approach required screening of 677 individuals with plasma p-tau217 to identify 100 Aβ-positive individuals, compared to 536 participants when using PET alone, it reduced the need for PET testing to 124. Immunoassays demonstrated comparable PPVs to mass spectrometry (80% [95% CI, 74-86] vs 85% [95% CI, 81-90]; P = .12) but significantly lower overall accuracy (82% [95% CI, 79-84]% vs 88 [95% CI, 86-90]; P < .001) and true Aβ-positive detection rate (49% [95% CI, 43-55] vs 69% [95% CI, 64-75]; P < .001). Conclusions and Relevance The findings highlight the potential of plasma p-tau217 as a stand-alone test—or when used in a sequential 2-step approach alongside PET or CSF testing—as a cost-effective, scalable, and minimally burdensome strategy for identifying preclinical AD. Tailored screening workflows that incorporate p-tau217 can improve efficiency in participant selection for preclinical AD trials and, in the future, help guide access to disease-modifying treatments.
Universal tau PET scale (Uniτ) – The HEAD Study

Alzheimer's & Dementia | January 9, 2025 | Volume: 20 | Issue: S2 | Pages: No page available

10.1002/alz.089555

Abstract Background The HEAD study aims to collect a large dataset of multiple tau‐PET tracers to provide robust anchor values for tau‐PET harmonization. Here, we tested the hypothesis that anchoring two tau tracer uptake values using head‐to‐head measurements has the potential to generate an accurate universal tau‐PET scale, named Uniτ(tau). Methods We assessed 200 individuals across the aging and AD spectrum (Training: HEAD data freeze 2.0, n=185; Testing: UPitt dataset (Gogola et al.), n=15) with [ 18 F]Flortaucipir and [ 18 F]MK‐6240 tau‐PET. SUVRs were processed to a common 8mm FWHM, with inferior cerebellar gray matter as the reference region (Pascoal et al.). Uniτ explored two anchoring/harmonization methods. First, we examined within‐tracer anchoring by creating anchor values based on the mean SUVR of Youngs (<25 years) and 95th percentile voxels from cognitively impaired individuals. Second, we explored within‐ plus between‐tracer anchoring, employing linear (e.g., piecewise) and non‐linear regressions. To address the inherent problem of discontinuity of piecewise transformations, we implemented two smoothing methods at the inflection point between equations, transforming them into a continuous function. Results Uniτ scale anchoring within‐tracer resulted in similar estimates for high values, but less accurate in the lower range (Figure 1,2). Anchoring within‐ plus between‐tracer improved estimate consistency, with the piecewise transformation generating the best results. The piecewise smoothing equation yielded estimates comparable to those obtained from the piecewise method without smoothing. This allowed for the use of a single formula. In addition, this leads to more robust results when the goal is to study longitudinal changes in the scale (data not shown). UPitt testing dataset showed similar results to the training set (Figure 3). Conclusion Our preliminary findings suggest that anchoring tau‐PET values both within and between tracers has the potential to harmonize tau‐PET tracers, while preserving their characteristics. Currently, piecewise smoothing is the preferred method for Uniτ, but we are continuously fine‐tuning scale parameters as we acquire more data. The final scale parameters will be determined based on extensive training and testing data from multiple tracers. This cautious methodology holds the promise of delivering reliable, robust, and reproducible results, ensuring safe usage of the scale in clinical trials, and potentially paving the way for future use in clinical practice.
Universal tau PET scale (Uniτ) – The HEAD Study

Alzheimer's & Dementia | January 9, 2025 | Volume: 20 | Issue: S9 | Pages: No page available

10.1002/alz.094383

AbstractBackgroundThe HEAD study aims to collect a large dataset of multiple tau‐PET tracers to provide robust anchor values for tau‐PET harmonization. Here, we tested the hypothesis that anchoring two tau tracer uptake values using head‐to‐head measurements has the potential to generate an accurate universal tau‐PET scale, named Uniτ(tau).MethodsWe assessed 200 individuals across the aging and AD spectrum (Training:HEAD data freeze 2.0, n=185; Testing:UPitt dataset (Gogola et al.), n=15) with [18F]Flortaucipir and [18F]MK‐6240 tau‐PET. SUVRs were processed to a common 8mm FWHM, with inferior cerebellar gray matter as the reference region (Pascoal et al.). Uniτ explored two anchoring/harmonization methods. First, we examined within‐tracer anchoring by creating anchor values based on the mean SUVR of Youngs (<25 years) and 95th percentile voxels from cognitively impaired individuals. Second, we explored within‐ plus between‐tracer anchoring, employing linear (e.g., piecewise) and non‐linear regressions. To address the inherent problem of discontinuity of piecewise transformations, we implemented two smoothing methods at the inflection point between equations, transforming them into a continuous function.ResultsUniτ scale anchoring within‐tracer resulted in similar estimates for high values, but less accurate in the lower range (Figure 1,2). Anchoring within‐ plus between‐tracer improved estimate consistency, with the piecewise transformation generating the best results. The piecewise smoothing equation yielded estimates comparable to those obtained from the piecewise method without smoothing. This allowed for the use of a single formula. In addition, this leads to more robust results when the goal is to study longitudinal changes in the scale (data not shown). UPitt testing dataset showed similar results to the training set (Figure 3).ConclusionOur preliminary findings suggest that anchoring tau‐PET values both within and between tracers has the potential to harmonize tau‐PET tracers, while preserving their characteristics. Currently, piecewise smoothing is the preferred method for Uniτ, but we are continuously fine‐tuning scale parameters as we acquire more data. The final scale parameters will be determined based on extensive training and testing data from multiple tracers. This cautious methodology holds the promise of delivering reliable, robust, and reproducible results, ensuring safe usage of the scale in clinical trials, and potentially paving the way for future use in clinical practice.
Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Alzheimer's & Dementia | July 23, 2024 | Volume: 20 | Issue: 9 | Pages: 5833-5848

10.1002/alz.13908 | PMID 39041435

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.