Citations 202

Dual-Energy CT for Quantification of Urinary Stone Composition in Mixed Stones: A Phantom Study

American Journal of Roentgenology | May 25, 2016 | Volume: 207 | Issue: 2 | Pages: 321-329

10.2214/ajr.15.15692 | PMID 27224260

The Role of the Medical Physicist in Managing Radiation Dose and Communicating Risk in CT

American Journal of Roentgenology | April 4, 2016 | Volume: 206 | Issue: 6 | Pages: 1241-1244

10.2214/ajr.15.15651 | PMID 27043790

Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 | PMID 26835839

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels

Investigative Radiology | January 27, 2016 | Volume: 51 | Issue: 7 | Pages: 421-429

10.1097/rli.0000000000000251 | PMID 26818529

Objectives The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. Materials and Methods A research dual-source PCD-CT scanner was used, where the “A” tube/detector subsystem used an EID and the “B” tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. Results For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. Conclusions The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.
The Role of Dynamic (4D) CT in the Detection of Scapholunate Ligament Injury

Journal of Wrist Surgery | January 18, 2016 | Volume: 05 | Issue: 04 | Pages: 306-310

10.1055/s-0035-1570463 | PMID 27777822

The Clinical Impact of Accurate Cystine Calculi Characterization Using Dual-Energy Computed Tomography

Case Reports in Radiology | November 25, 2015 | Volume: 2015 | Issue: No issue available | Pages: 1-5

10.1155/2015/801021 | PMID 26688770

Dual-energy computed tomography (DECT) has recently been suggested as the imaging modality of choice for kidney stones due to its ability to provide information on stone composition. Standard postprocessing of the dual-energy images accurately identifies uric acid stones, but not other types. Cystine stones can be identified from DECT images when analyzed with advanced postprocessing. This case report describes clinical implications of accurate diagnosis of cystine stones using DECT.
Characterization of Urinary Stone Composition by Use of Third-Generation Dual-Source Dual-Energy CT With Increased Spectral Separation

American Journal of Roentgenology | November 20, 2015 | Volume: 205 | Issue: 6 | Pages: 1203-1207

10.2214/ajr.15.14348 | PMID 26587926

Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method

American Journal of Roentgenology | October 24, 2015 | Volume: 205 | Issue: 5 | Pages: 1026-1037

10.2214/ajr.14.14185 | PMID 26496550

Radiation Dose Reduction in Dual-Energy CT: Does It Affect the Accuracy of Urinary Stone Characterization?

American Journal of Roentgenology | July 23, 2015 | Volume: 205 | Issue: 2 | Pages: W172-W176

10.2214/ajr.14.12929 | PMID 26204304

A Technique for Quantifying Wrist Motion Using Four-Dimensional Computed Tomography: Approach and Validation

Journal of Biomechanical Engineering | April 22, 2015 | Volume: 137 | Issue: 7 | Pages: No page available

10.1115/1.4030405 | PMID 25901447

Accurate quantification of subtle wrist motion changes resulting from ligament injuries is crucial for diagnosis and prescription of the most effective interventions for preventing progression to osteoarthritis. Current imaging techniques are unable to detect injuries reliably and are static in nature, thereby capturing bone position information rather than motion which is indicative of ligament injury. A recently developed technique, 4D (three dimensions + time) computed tomography (CT) enables three-dimensional volume sequences to be obtained during wrist motion. The next step in successful clinical implementation of the tool is quantification and validation of imaging biomarkers obtained from the four-dimensional computed tomography (4DCT) image sequences. Measures of bone motion and joint proximities are obtained by: segmenting bone volumes in each frame of the dynamic sequence, registering their positions relative to a known static posture, and generating surface polygonal meshes from which minimum distance (proximity) measures can be quantified. Method accuracy was assessed during in vitro simulated wrist movement by comparing a fiducial bead-based determination of bone orientation to a bone-based approach. The reported errors for the 4DCT technique were: 0.00–0.68 deg in rotation; 0.02–0.30 mm in translation. Results are on the order of the reported accuracy of other image-based kinematic techniques.