Citations 202

Technical Note: Insertion of digital lesions in the projection domain for dual‐source, dual‐energy CT

Medical Physics | February 27, 2017 | Volume: 44 | Issue: 5 | Pages: 1655-1660

10.1002/mp.12185 | PMID 28241103

PurposeTo compare algorithms performing material decomposition and classification in dual‐energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual‐source, dual‐energy CT system.MethodsA model that takes into account beam‐hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x‐ray energy spectra, the patient/phantom attenuation, and the x‐ray detector energy response. The beam‐hardening model was validated on samples of iodine (I) and calcium (Ca) for a second‐generation dual‐source, dual‐energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x‐ray energy spectra using the developed beam‐hardening model. Each digital stone was inserted in the dual‐energy projection data of a water phantom scanned on a dual‐source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual‐energy data was validated by comparing CT number accuracy and high‐contrast resolution of simulated dual‐energy CT data of the ACR phantom with experimentally acquired data.ResultsThe beam‐hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the literature. A sample application of the proposed tool was also demonstrated.ConclusionA framework was developed and validated for the creation of digital objects of known mineral composition, and for inserting the digital objects into projection data from a commercial dual‐source, dual‐energy CT scanner. Among other applications, it will allow a systematic investigation of the impact of scan and reconstruction parameters on kidney stone dual‐energy properties under rigorously controlled conditions.
An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features

Medical Physics | February 25, 2017 | Volume: 44 | Issue: 5 | Pages: 1610-1623

10.1002/mp.12174 | PMID 28236645

PurposeTo develop and evaluate an image‐domain noise reduction method for multi‐energy CT (MECT) data.MethodsMulti‐Energy Non‐Local Means (MENLM) is a technique that uses the redundant information in MECT images to achieve noise reduction. In this method, spatio‐spectral features are used to determine the similarity between pixels, making the similarity evaluation more robust to image noise. The performance of this MENLM filter was tested on images acquired on a whole‐body research photon counting CT system. The impact of filtering on image quality was quantitatively evaluated in phantom studies in terms of image noise level (standard deviation of pixel values), noise power spectrum (NPS), in‐plane and cross‐plane spatial resolution, CT number accuracy, material decomposition performance, and subjective low‐contrast spatial resolution using the American College of Radiology (ACR) CT accreditation phantom. Clinical feasibility was assessed by performing MENLM on contrast‐enhanced swine images and unenhanced cadaver head images using clinically relevant doses and dose rates.ResultsThe phantom studies demonstrated that the MENLM filter reduced noise substantially and still preserved the shape and peak frequency of the NPS. With 80% noise reduction, MENLM filtering caused no degradation of high‐contrast spatial resolution, as illustrated by the modulation transfer function (MTF) and slice sensitivity profile (SSP). CT number accuracy was also maintained for all energy channels, demonstrating that energy resolution was not affected by filtering. Material decomposition performance was improved with MENLM filtering. The subjective evaluation using the ACR phantom demonstrated an improvement in low‐contrast performance. MENLM achieved effective noise reduction in both contrast‐enhanced swine images and unenhanced cadaver head images, resulting in improved detection of subtle vascular structures and the differentiation of white/gray matter.ConclusionIn MECT, MENLM achieved around 80% noise reduction and greatly improved material decomposition performance and the detection of subtle anatomical/low‐contrast features while maintaining spatial and energy resolution. MENLM filtering may improve diagnostic or functional analysis accuracy and facilitate radiation dose and contrast media reduction for MECT.
Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 | PMID 28225687

Advocating for use of the ALARA principle in the context of medical imaging fails to recognize that the risk is hypothetical and so serves to reinforce patients' fears of radiation

Medical Physics | January 3, 2017 | Volume: 44 | Issue: 1 | Pages: 3-6

10.1002/mp.12012 | PMID 28044339

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 | PMID 28042589

Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner

Journal of Medical Imaging | December 14, 2016 | Volume: 3 | Issue: 4 | Pages: 043503

10.1117/1.jmi.3.4.043503 | PMID 28018936

Arterial wall perfusion measured with photon counting spectral x-ray CT

SPIE Proceedings | October 4, 2016 | Volume: 9967 | Issue: No issue available | Pages: 99670B

10.1117/12.2238817 | PMID 27807391

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector

SPIE Proceedings | October 3, 2016 | Volume: 9969 | Issue: No issue available | Pages: 99690J

10.1117/12.2236501 | PMID 27795606

Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography

Physics in Medicine & Biology | August 23, 2016 | Volume: 61 | Issue: 18 | Pages: 6707-6732

10.1088/0031-9155/61/18/6707 | PMID 27551878

Abstract Photon-counting computed tomography (PCCT) is an emerging imaging technique that enables multi-energy imaging with only a single scan acquisition. To enable multi-energy imaging, the detected photons corresponding to the full x-ray spectrum are divided into several subgroups of bin data that correspond to narrower energy windows. Consequently, noise in each energy bin increases compared to the full-spectrum data. This work proposes an iterative reconstruction algorithm for noise suppression in the narrower energy bins used in PCCT imaging. The algorithm is based on the framework of prior image constrained compressed sensing (PICCS) and is called spectral PICCS; it uses the full-spectrum image reconstructed using conventional filtered back-projection as the prior image. The spectral PICCS algorithm is implemented using a constrained optimization scheme with adaptive iterative step sizes such that only two tuning parameters are required in most cases. The algorithm was first evaluated using computer simulations, and then validated by both physical phantoms and in vivo swine studies using a research PCCT system. Results from both computer-simulation and experimental studies showed substantial image noise reduction in narrow energy bins (43–73%) without sacrificing CT number accuracy or spatial resolution.
Construction of realistic phantoms from patient images and a commercial three-dimensional printer

Journal of Medical Imaging | July 8, 2016 | Volume: 3 | Issue: 3 | Pages: 033501

10.1117/1.jmi.3.3.033501 | PMID 27429998