Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values

Medical Physics | May 6, 2017 | Volume: 44 | Issue: 8 | Pages: 4262-4275

10.1002/mp.12314 | PMID 28477342

PurposeThe vast majority of body CT exams are performed with automatic exposure control (AEC), which adapts the mean tube current to the patient size and modulates the tube current either angularly, longitudinally or both. However, most radiation dose estimation tools are based on fixed tube current scans. Accurate estimates of patient dose from AEC scans require knowledge of the tube current values, which is usually unavailable. The purpose of this work was to develop and validate methods to accurately estimate the tube current values prescribed by one manufacturer's AEC system to enable accurate estimates of patient dose.MethodsMethods were developed that took into account available patient attenuation information, user selected image quality reference parameters and x‐ray system limits to estimate tube current values for patient scans. Methods consistent with AAPM Report 220 were developed that used patient attenuation data that were: (a) supplied by the manufacturer in the CT localizer radiograph and (b) based on a simulated CT localizer radiograph derived from image data. For comparison, actual tube current values were extracted from the projection data of each patient. Validation of each approach was based on data collected from 40 pediatric and adult patients who received clinically indicated chest (n = 20) and abdomen/pelvis (n = 20) scans on a 64 slice multidetector row CT (Sensation 64, Siemens Healthcare, Forchheim, Germany). For each patient dataset, the following were collected with Institutional Review Board (IRB) approval: (a) projection data containing actual tube current values at each projection view, (b) CT localizer radiograph (topogram) and (c) reconstructed image data. Tube current values were estimated based on the actual topogram (actual‐topo) as well as the simulated topogram based on image data (sim‐topo). Each of these was compared to the actual tube current values from the patient scan. In addition, to assess the accuracy of each method in estimating patient organ doses, Monte Carlo simulations were performed by creating voxelized models of each patient, identifying key organs and incorporating tube current values into the simulations to estimate dose to the lungs and breasts (females only) for chest scans and the liver, kidney, and spleen for abdomen/pelvis scans. Organ doses from simulations using the actual tube current values were compared to those using each of the estimated tube current values (actual‐topo and sim‐topo).ResultsWhen compared to the actual tube current values, the average error for tube current values estimated from the actual topogram (actual‐topo) and simulated topogram (sim‐topo) was 3.9% and 5.8% respectively. For Monte Carlo simulations of chest CT exams using the actual tube current values and estimated tube current values (based on the actual‐topo and sim‐topo methods), the average differences for lung and breast doses ranged from 3.4% to 6.6%. For abdomen/pelvis exams, the average differences for liver, kidney, and spleen doses ranged from 4.2% to 5.3%.ConclusionsStrong agreement between organ doses estimated using actual and estimated tube current values provides validation of both methods for estimating tube current values based on data provided in the topogram or simulated from image data.
Consistency of Renal Stone Volume Measurements Across CT Scanner Model and Reconstruction Algorithm Configurations

American Journal of Roentgenology | April 12, 2017 | Volume: 209 | Issue: 1 | Pages: 116-121

10.2214/ajr.16.16940 | PMID 28402129

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323Q

10.1117/12.2255736 | PMID 28392613

Detection of increased vasa vasorum in artery walls: improving CT number accuracy using image deconvolution

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323O

10.1117/12.2255676 | PMID 28413240

Ultra-high spatial resolution multi-energy CT using photon counting detector technology

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320Y

10.1117/12.2255589 | PMID 28392615

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101321R

10.1117/12.2255593 | PMID 28392614

Practical implementation of channelized hotelling observers: effect of ROI size

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320G

10.1117/12.2255530 | PMID 28943699

Dual energy CT kidney stone differentiation in photon counting computed tomography

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 1013237

10.1117/12.2252021 | PMID 28943700

A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.