Introduction: Axial and centrifugal-flow left ventricular assist devices (LVAD) have varied response to changes in loading conditions. Whether ventricular size modulates the response to LVAD therapy between the axial flow Heartmate II (HMII) and centrifugal flow Heartware (HVAD) is unknown. Hypothesis: Adverse event and survival rates between devices are affected by recipient pre-op left ventricular end-diastolic diameter (LVEDD). Methods: Data on 1,149 continuous-flow LVAD recipients from May 2004 to May 2015 was pooled from the Mechanical Circulatory Support Research Network (MCSRN). The effect of pre-op LVEDD on the instantaneous hazard of death and adverse events was evaluated between HMII (n=864) and HVAD (n=283). Results: The average LVEDD was 7.0cm and did not differ between the device recipients. Patients with a smaller LVEDD (≤ 6.3cm) were more likely female 39% v. 24% (p < 0.0001) and to have an ischemic cardiomyopathy (30% v. 24%, p = 0.045). For every 1cm increase in pre-op LVEDD, the adjusted hazard ratio (HR) for mortality increased with HVAD (HR 1.31, 95% CI 0.94-1.82, p = 0.005) and decreased with HMII (HR 0.78, 95% CI 0.67-0.92, p = 0.005), Figure 1a. Other predictors of mortality included age (HR 1.31, 95% CI 1.12 - 1.53 per 10y, p < 0.001) and bilirubin (HR 1.15, 95% CI 0.94-1.42 per mg/dL, p = 0.027). LVEDD by device type interaction was not a significant predictor of gastrointestinal bleeding or pump thrombosis. The risk of stroke increased with LVEDD for HVAD and decreased for HMII, but this did not reach statistical significance, Figure 1b. Ischemic etiology of heart failure (HR 1.7 95% CI 1.14 - 2.55, p = 0.01) and HVAD device use (HR 1.47 95% CI 1.00 - 2.17, p = 0.03) were significant predictors of stroke. Conclusions: Our data suggest important differences exist in patient outcomes between HMII and HVAD based on pre-op ventricular size. Studies are needed to determine if these differences in outcome are due to device or flow-specific differences in patient support.
Improving Outcomes on Destination Therapy Will Define the Future of Assist Devices
Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise–induced hypoxemia (O 2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4–57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO 2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6–322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.
Diastolic Pulmonary Gradient as a Predictor of Right Ventricular Failure After Left Ventricular Assist Device Implantation
Journal of the American Heart Association | August 14, 2019 | Volume: 8 | Issue: 16 | Pages: No page available
Background Diastolic pulmonary gradient ( DPG ) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance ( PVR ) and transpulmonary gradient ( TPG ). The prognostic significance of DPG in patients requiring a left ventricular assist device ( LVAD ) remains unclear. We sought to investigate whether pre‐ LVAD DPG is a predictor of survival or right ventricular ( RV ) failure post‐ LVAD . Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all‐cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan–Meier analyses. After a mean follow‐up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [ HR ]: 3.30; P =0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR ( HR 1.85, P =0.13 for PVR ≥3 versus PVR <3) or TPG ( HR 1.47, P =0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk ( HR 1.16, P =0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR , but not TPG , was associated with higher mortality risk ( HR 1.55; P =0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
The International Journal of Artificial Organs | August 14, 2019 | Volume: 43 | Issue: 2 | Pages: 99-108
Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m −2 ) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
Preoperative Risk Stratification of Right Ventricular Function Utilizing Cardiac Magnetic Resonance Imaging Compared With Echocardiographic and Hemodynamic Parameters
Accurate right ventricle functional analysis prior to mechanical circulatory support continues to be valuable for preoperative stratification of patients at risk for developing right ventricular (RV) failure. While cardiac magnetic resonance imaging (CMR) remains the gold standard, CMR is limited by availability and patient-specific contraindications. Further investigation of other imaging modalities would be beneficial as it may serve as a surrogate to identifying RV systolic dysfunction. A single-center, retrospective study including 29 patients with advanced heart failure was performed. All patients underwent ventricular functional analysis with both CMR and echocardiography, and 19 patients underwent right heart catheterization. Predictability with multimodal assessment of RV function was determined using logistic regression methods. Of the 29 participants, 10 had severe RV dysfunction. Tricuspid annular plane of systolic excursion was a modest predictor of RV dysfunction with odd ratio (OR) of 0.07 (0.01–0.72) and c-statistic of 0.79. Invasive hemodynamic measurement of cardiac index by thermodilution method was also predictive of RV dysfunction but failed to reach statistical significance (OR of 0.03, <0.001–1.28) with c-statistic of 0.83. The role of invasive hemodynamic data in predicting RV function compared with CMR should be further explored among patients with advanced heart failure.
Intramyocardial Injection of Mesenchymal Precursor Cells and Successful Temporary Weaning From Left Ventricular Assist Device Support in Patients With Advanced Heart Failure
Abstract OBJECTIVES Limited literature is available on the best management strategy for tricuspid valve (TV) disease in adults. We sought to review our long-term outcomes of TV surgery with regard to survival and reoperation. METHODS A retrospective analysis of all patients ≥18 years of age [n = 2541, aged 67 ± 13years, 1433 (56%) females] who underwent first-time TV surgery between January 1993 and December 2013 was done. There were 1735 patients who received TV repair and 806 patients underwent replacement. A gradient boosting machine model was used to derive a propensity score for predicting replacement using 27 preoperative characteristics. Four hundred and eighteen propensity-matched pairs of TV repair and replacement were identified. Cox proportional hazard regression was used on the matched subset to determine the effect of replacement. RESULTS Functional TV regurgitation was present in 54% (n = 1369). A bioprosthesis was used in 84% (n = 680) of replacements, while 54% (n = 934) of TV repairs were ring annuloplasties. Operative mortality was 8% (n = 212). Overall survival was 54%, 29% and 13% at 5, 10 and 15 years, respectively. After propensity score matching, replacement was significantly associated with increased mortality [hazard ratio (HR) 1.54, 95% confidence interval (CI) 1.18–2.00; P = 0.001]. The cumulative incidence of TV reoperation was similar between the 2 groups when accounting for the competing risk of death [Fine–Gray HR 1.56, 95% CI 0.9–2.8; P = 0.144]. CONCLUSIONS TV surgery is associated with poor outcomes due to multiple patient comorbidities. TV repair results in better survival compared to replacement in patients with similar comorbidities with no increased risk of getting a reoperation.
Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
Journal of the American Heart Association | February 13, 2019 | Volume: 8 | Issue: 4 | Pages: No page available
Background Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cf LVADs ). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. Methods and Results To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cf LVAD was developed. Patients implanted with cf LVAD s underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient ( TAG ) was established. Thirty eight patients with cf LVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG . A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. Conclusions Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cf LVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.
Mitochondrial Morphology, Dynamics, and Function in Human Pressure Overload or Ischemic Heart Disease With Preserved or Reduced Ejection Fraction
Circulation: Heart Failure | February 12, 2019 | Volume: 12 | Issue: 2 | Pages: No page available
Background: The FOXO3a (forkhead box O3a)-BNIP3 (B-cell lymphoma 2/adenovirus E1B 19kDa interacting protein 3) pathway modulates mitochondrial dynamics and function and contributes to myocardial remodeling in rodent models of heart failure. We sought to investigate the expression of this pathway along with the expression of mitochondrial biogenesis (PGC-1α [peroxisome proliferator-activated receptor-γ coactivator-1α]), dynamics (DRP-1 [dynamin-related protein 1], OPA-1 [optic atrophy 1], and MFN 2 [mitofusin 2]), and oxidative phosphorylation (citrate synthase and electron transport chain complexes) markers and COX IV (cytochrome C oxidase) activity in myocardium from patients with valvular or ischemic heart disease and heart failure with preserved ejection fraction (HFpEF) or heart failure with reduced ejection fraction (HFrEF). Methods and Results: Subepicardial left ventricular biopsies (10×1×1 mm 3 ) were obtained at aortic valve replacement (HFpEF AVR , n=5; and HFrEF AVR , n=4), coronary artery bypass grafting (HFpEF CABG , n=5; and HFrEF CABG , n=5), or left ventricular assist device implantation (HFrEF LVAD , n=4). Subepicardial biopsies from patients with normal left ventricular function (n=2) and from donor hearts (n=3) served as controls (normal). Relative to normal, mitochondrial fragmentation and cristae destruction were evident, and mitochondrial area was decreased in HFpEF; 1.00±0.09 versus 0.71±0.08; P =0.016. These mitochondrial morphological changes were more pronounced in HFrEF (0.54±0.06); P =0.002 HFpEF versus HFrEF. BNIP3 (monomer+dimer) expression was increased in HFpEF (3.99±2.44) and in HFrEF (5.19±1.70) relative to normal; P =0.004 and P <0.001, respectively. However, BNIP3 monomer was increased in HFrEF (4.32±1.43) compared with normal (0.99±0.06) and HFpEF (1.97±0.90); P =0.001 and 0.004, respectively. The HFrEF group uniquely showed increase in DRP-1 expression (1.94±0.38) and decreases in PGC-1α expression (0.61±0.07) and COX IV activity (0.70±0.10) relative to normal; P =0.013, P <0.001, and P <0.001, respectively, with no significant change in electron transport chain complexes expression. Conclusions: These findings in human myocardium confirm studies in rodents where contractile dysfunction is associated with activation of the FOXO3a-BNIP3 pathway and altered mitochondrial dynamics, biogenesis, and function.