Citations 34

Improving Universal Protocol Performance in Radiology through Implementation of a Standardized Time-out

RadioGraphics | July 1, 2020 | Volume: 40 | Issue: 4 | Pages: 1182-1187

10.1148/rg.2020190127 | PMID 32609592

Implementing a Radiology Residency Quality Curriculum to Develop Physician Leaders and Increase Value for Patients

RadioGraphics | February 14, 2020 | Volume: 40 | Issue: 2 | Pages: 505-514

10.1148/rg.2020190140 | PMID 32058836

Procedure-Related Pain During Image-Guided Percutaneous Biopsies: A Retrospective Study of Prevalence and Predictive Factors

American Journal of Roentgenology | July 9, 2019 | Volume: 213 | Issue: 4 | Pages: 755-761

10.2214/ajr.19.21248 | PMID 31287724

Recurrence and survival outcomes following percutaneous thermal ablation of oligometastatic melanoma.

Journal of Clinical Oncology | April 19, 2019 | Volume: 33 | Issue: 15_suppl | Pages: e20040-e20040

10.1200/jco.2015.33.15_suppl.e20040

Frequency of Bleeding Complications After Percutaneous Core Needle Biopsy and the Association With Aspirin Usage and Length of Aspirin Discontinuation

American Journal of Roentgenology | April 17, 2019 | Volume: 213 | Issue: 1 | Pages: 211-215

10.2214/ajr.18.20366 | PMID 30995091

Patient-Reported Outcomes After Percutaneous Renal Ablation: Initial Experience

American Journal of Roentgenology | January 8, 2019 | Volume: 212 | Issue: 3 | Pages: 672-676

10.2214/ajr.17.19463 | PMID 30620680

Thermal Ablation of Bone Metastases

Seminars in Interventional Radiology | November 5, 2018 | Volume: 35 | Issue: 04 | Pages: 299-308

10.1055/s-0038-1673422 | PMID 30402013

AbstractImage-guided, minimally invasive, percutaneous thermal ablation of bone metastases has unique advantages compared with surgery or radiation therapy. Thermal ablation of osseous metastases may result in significant pain palliation, prevention of skeletal-related events, and durable local tumor control. This article will describe current thermal ablation techniques utilized to treat bone metastases, summarize contemporary evidence supporting such thermal ablation treatments, and outline an approach to percutaneous ablative treatment.
Introduction of Microwave Ablation Into a Renal Ablation Practice: Valuable Lessons Learned

American Journal of Roentgenology | September 24, 2018 | Volume: 211 | Issue: 6 | Pages: 1381-1389

10.2214/ajr.18.19775 | PMID 30247980

Reply to E.L. Pollom et al, N. Ohri et al, A. Fiorentino et al, D.R. Wahl et al, N. Kim et al, J. Boda-Heggemann et al, S. Rana et al, N. Sanuki et al, J.R. Olsen et al, G.L. Smith et al, and A. Shinde et al

Journal of Clinical Oncology | June 27, 2018 | Volume: 36 | Issue: 24 | Pages: 2567-2569

10.1200/jco.2018.78.6418 | PMID 29945519

Development of a robust MRI fiducial system for automated fusion of MR‐US abdominal images

Journal of Applied Clinical Medical Physics | May 22, 2018 | Volume: 19 | Issue: 4 | Pages: 261-270

10.1002/acm2.12352 | PMID 29785834

AbstractWe present the development of a two‐component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto‐segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center‐of‐mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm‐measured inter‐marker spacings and actual separation distances were 0.53 ± 0.36 mm. “Proof‐of‐concept” automatic MR‐US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath‐hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences.