Citations 29

Bioorthogonal “Click Chemistry” Bone Cement Enables Pro-Translational Spinal Fusion in a Large Animal Sheep Model

ACS Biomaterials Science & Engineering | May 4, 2026 | Volume: 12 | Issue: 6 | Pages: 3054-3068

10.1021/acsbiomaterials.6c00348 | PMID 42080332

Dr. Albert L. Rhoton Jr. and His Lasting Impact on Neurosurgery

Journal of Neurological Surgery Part B: Skull Base | February 27, 2026 | Volume: 87 | Issue: No issue available | Pages: No page available

10.1055/s-0046-1819366

Risk Factors for Surgical Revision Following Ventricular Shunt Placement for Idiopathic Normal Pressure Hydrocephalus

Operative Neurosurgery | February 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1227/ons.0000000000001964 | PMID 41705955

BACKGROUND AND OBJECTIVES: Ventriculoperitoneal shunt (VPS) placement is a common treatment for idiopathic normal pressure hydrocephalus (iNPH), but patients may require VPS revision. This study aims to evaluate the effectiveness of a standardized VPS placement protocol by comparing indications and rates of shunt revision compared with a historical institutional cohort. METHODS: All patients treated with VPS for “suspected” iNPH at a tertiary care center between January 2000 and January 2023 were retrospectively reviewed and divided into temporally distinct historical (before 2017) and standardized (after 2017) cohorts. Cumulative incidence and timing of VPS revision were compared using competing risks analyses. RESULTS: A total of 561 patients (median age 75.0 years) were identified with 324 (57.8%) in the historical and 237 (42.2%) in the standardized cohorts. Significant variations in surgical technique and shunt hardware were noted between the cohorts. With a median follow-up of 11.4 months for historical and 12.4 months for standardized cohort, shunt revisions occurred in 19.4% and 8.4% of patients in the historical and standardized cohorts, respectively ( P < .001). Revision indications also varied significantly with lower rates of overdrainage ( P < .001), infection ( P < .001), and proximal malfunction ( P = .042) but higher rate of distal malfunction ( P = .03) in the standardized cohort. Notably, no infections were noted in the standardized cohort. CONCLUSION: Risk of shunt revision among iNPH patients may be associated with modifiable factors related to surgical technique and shunt hardware selection. Importantly, no short-term complications such as hemorrhage, infection, or catheter malposition were observed with the standardized protocol. Development and refinement of standardized shunt protocols for iNPH patients should be commonplace to facilitate tracking, identification, and modification of modifiable technical risk factors.
3D Osteoimmune Stem Cell Spheroids with Osteoinduction and Immunomodulation Dual Functionality for In Vivo Bone Tissue Engineering

ACS Biomaterials Science & Engineering | January 9, 2026 | Volume: 12 | Issue: 2 | Pages: 1127-1141

10.1021/acsbiomaterials.5c01643 | PMID 41510644

Achieving Alignment and Implant-Specific Goals in Anterior Lumbar Interbody Fusion, and Predictors of Postoperative Intradiscal Lordosis: The Role of Spinopelvic Parameters, Cage Lordosis, Intraoperative Consistency, Surgical Technique, and Treated Level

Operative Neurosurgery | December 29, 2025 | Volume: 31 | Issue: 3 | Pages: 431-444

10.1227/ons.0000000000001868 | PMID 41460067

BACKGROUND AND OBJECTIVES: Anterior lumbar interbody fusion (ALIF) is a powerful procedure for sagittal correction and indirect decompression in the lumbar spine, though aggressive correction can cause stretch neuropraxia and implant subsidence. The aim of this study was to identify radiographic and clinical predictors of segmental correction, as well as to evaluate the degree to which segmental correction on supine intraoperative radiographs translates to postoperative upright alignment changes. METHODS: We identified patients treated with 1- or 2-level ALIF at a tertiary care center and extracted data on demographics, spinopelvic parameters, and surgical details. Patients treated with isolated ALIF and ALIF with supplementary posterior instrumentation were compared on pre- and postoperative intradiscal lordosis (IDL) and change in IDL. Multivariable linear regression was performed to identify independent predictors of postoperative IDL. RESULTS: We included 204 patients (median age 57 years, 55.4% male) treated at 258 levels, of whom 114 (55.9%) underwent supplementary posterior fixation and 150 (73.5%) underwent single-level implantation. Across all patients, postoperative IDL was significantly greater than preoperative segmental lordosis (25.4° vs 15.3°; P < .001). Standalone ALIF achieved less ΔIDL than circumferential fusion for L5/S1 procedures (7.4° vs 11.6°; P < .001), though ΔIDL for L3/4 and L4/5 was similar between the standalone and circumferential groups. Multivariable analysis showed postoperative IDL to be predicted by greater preoperative IDL (β = 0.26° per degree; [0.15, 0.36]; P < .001), L5/S1 [vs L4/5] implantation (β = 3.97°; [2.72, 5.21]; P < .001), use of supplementary posterior fixation (β = 1.80°; [0.70, 2.89]; P < .001), and greater implant lordosis (β = 0.62° per degree; [0.44, 0.79]; P < .001). CONCLUSION: Postoperative IDL after 1- or 2-level ALIF is best predicted by placement of larger interbody sizes, L5/S1 implantation, greater baseline IDL, and use of adjunct posterior fixation. Patients with higher preoperative lordosis experienced smaller postoperative increases in IDL, though this was likely influenced by a treatment bias.
Predictors of maximizing the degree of listed interbody lordosis imparted during one- or two-level transforaminal lumbar interbody fusion for degenerative pathology

Journal of Neurosurgery: Spine | November 17, 2025 | Volume: 44 | Issue: 1 | Pages: 80-89

10.3171/2025.5.spine241012 | PMID 40972048

OBJECTIVE Lordotic devices have garnered increased attention for improving the segmental lordosis (SL) achieved with transforaminal lumbar interbody fusion (TLIF). However, it is unclear the degree to which surgeons maximize the "ideal" or listed lordosis of the interbody device. METHODS Patients undergoing one- or two-level TLIF for degenerative pathologies were identified and data were extracted on demographics, baseline lumbopelvic radiographic parameters, and TLIF details. The primary outcome of interest was the degree to which postoperative SL approximated the listed cage lordosis (Δtarget). Change in SL was a secondary outcome. Linear mixed-effects modeling was used to identify significant predictors of the percentage of ideal lordosis achieved. RESULTS A total of 239 treated levels were included (median patient age 66.6 years; 56.9% female); 151 levels were part of single-level TLIF constructs. The median segmental corrections were a 2.8° increase in SL and 2.8 mm in disc height. The median difference between listed cage lordosis and postoperative SL (Δtarget) was 0.5°. However, only 56.1% of levels achieved at least the listed cage lordosis. Linear mixed-effects modeling found that independent predictors of Δtarget were lower implant lordosis (estimate −1.01° [95% CI −1.15° to −0.87°] per degree, p < 0.001), greater preoperative SL (estimate 0.38° [95% CI 0.28°–0.48°] per degree, p < 0.001), greater preoperative PI (estimate 0.06° [95% CI 0.02°–0.11°] per degree, p = 0.007), and closer approximation of the anterior apophyseal ring of the caudal vertebrae (estimate −0.27° [95% CI −0.39° to −0.15°] per mm, p < 0.001). Similarly, independent predictors of postoperative SL were larger implant lordosis (estimate 0.16° [95% CI 0.05°–0.27°] per degree, p = 0.004), lower preoperative SL (estimate −0.70° [95% CI −0.79° to −0.62°] per degree, p < 0.001), greater preoperative PI (estimate 0.08° [95% CI 0.04°–0.12°] per degree, p < 0.001), and closer approximation of the anterior apophyseal ring of the cranial vertebrae (estimate −0.15° [95% CI −0.28° to −0.03°] per mm, p = 0.014). CONCLUSIONS The present results suggest that while lordosing, only 56% TLIF operations obtain the listed interbody lordosis ("target" lordosis). Anterior placement within the disc space is the only modifiable intraoperative technical factor for maximizing lordosis for a given interbody, highlighting the importance of effective disc space exenteration.
Visible Light Induced DLP‐Printed Oxygen‐Releasing TPMS Scaffolds Mitigate Early Hypoxia in Bone Defects

Advanced Healthcare Materials | September 23, 2025 | Volume: 15 | Issue: 3 | Pages: No page available

10.1002/adhm.202502735 | PMID 40985752

Abstract Oxygen deprivation within large or poorly vascularized bone defects remains a key barrier to successful regeneration, especially during the early postimplantation period before vascular ingrowth. Here, the development of COSnPPOD (CaO 2 –Silica NP Platform for Osteogenic Development) is reported, a visible light digital light processing‐printed hydrogel scaffold that integrates oxygen‐releasing nanoparticles (NPs) within a Primitive‐type triply periodic minimal surface architecture. The scaffold combines a gelatin methacrylate‐poly(ethylene glycol) diacrylate matrix with calcium peroxide (CaO 2 )‐loaded hollow silica NPs, enabling localized, short‐term oxygen release while preserving structural fidelity. COSnPPOD scaffolds demonstrate favorable degradation kinetics, tunable stiffness, and increased protein adsorption in vitro. In a preosteoblast model, COSnPPOD maintains cell viability and supports osteogenic gene expression without cytotoxic effects. While overall gene expression is comparable to controls, a 16‐fold increased expression of phosphoprotein 1 (Spp1) suggests scaffold‐driven activation of matrix remodeling pathways. In vivo, COSnPPOD scaffolds enhance bone regeneration in a murine calvarial defect model, with significantly greater bone formation and collagen deposition than untreated defects and hydrogel controls. Additionally, vascular endothelial growth factor immunostaining is increased within the defect, consistent with a proangiogenic response, and no systemic toxicity is observed. These findings establish COSnPPOD as a promising scaffold system that combines sustained oxygenation with biomimetic geometry to support localized bone regeneration.
The superiority of endplate Hounsfield units relative to cervical vertebral Hounsfield units in predicting subsidence after anterior cervical discectomy and fusion

Journal of Neurosurgery: Spine | September 12, 2025 | Volume: 43 | Issue: 6 | Pages: 672-680

10.3171/2025.4.spine241067 | PMID 40779794

OBJECTIVE The present investigation aimed to 1) develop a new CT-based assessment of endplate bone density (endplate Hounsfield unit [EP-HU]) and 2) analyze if EP-HU was a better predictor than vertebral Hounsfield unit (HU) for subsidence after anterior cervical discectomy and fusion (ACDF). METHODS All adult patients who underwent one- to three-level ACDF with a titanium interbody for radiculopathy and/or myelopathy at an academic center between 2018 and 2020 were retrospectively identified. Based on preoperative sagittal CT scans (left, right, and middle cuts), 2-mm superior and inferior endplate regions were circumscribed with the free draw tool to account for endplate surface undulations. The average of the superior and inferior EP-HUs on all CT cuts was used to calculate EP-HU. Cervical vertebral HUs were determined from the average of axial CT cranial, middle, and caudal cuts circumscribing only trabecular bone. The interbody subsidence of the cranial and caudal endplates of each ACDF level was directly measured on the endplate-facing surface of both coronal and sagittal cuts of postoperative CT scans (at 1 year) to determine the maximum subsidence (subsidence defined as ≥ 2 mm). Univariate and stepwise logistic regression analyses were used to compare subsidence based on CT bone metrics. Receiver operating characteristic (ROC) curve analyses were used to determine the probability of subsidence based on EP-HUs and vertebral HUs. RESULTS A total of 35 patients were included. Subsidence occurred at 32 of 67 unique fusion levels. Subsidence was associated with older age (p = 0.008), diabetes diagnosis (p = 0.015), and decreased interbody length (p = 0.019). EP-HUs exhibited moderate correlation with cervical vertebral HUs (Pearson’s ρ = 0.63). Subsidence was significantly associated with decreased total EP-HUs (subsidence: 475 HU, no subsidence: 543 HU; p = 0.019) and decreased lumbar vertebral HUs (subsidence: 296 HU, no subsidence: 341 HU; p = 0.011). ROC curve analysis identified an optimal EP-HU cutoff of 512.30 (area under the curve [AUC] = 0.701) to predict subsidence. The AUC of the vertebral HUs with respect to subsidence was 0.662. EP-HUs < 512.30 predicted subsidence (OR 6.67, p = 0.001) independent of significant demographic and surgical factors. CONCLUSIONS CT cervical EP-HUs rather than vertebral cervical trabecular HUs may be more efficacious in predicting subsidence after ACDF.
Lumbar Endplate Hounsfield Units Enhance Transforaminal Lumbar Interbody Fusion Subsidence Prediction Compared to Trabecular Hounsfield Units Alone

Global Spine Journal | July 4, 2025 | Volume: 16 | Issue: 1 | Pages: 639-649

10.1177/21925682251356986 | PMID 40613106

Study Design Retrospective cohort analysis. Objective (1) Develop a novel computed tomography (CT)-based assessment of endplate bone density (EP-HU), (2) Determine if EP-HU was a stronger predictor than trabecular HU for subsidence after transforaminal lumbar interbody fusion (TLIF). Methods All adult patients who underwent single-level TLIF for lumbar degenerative conditions at an academic center between 2017-2022 were retrospectively identified. EP-HU was calculated from a 2 mm superior and inferior endplate region on the preoperative mid sagittal CT scans, accounting for surface undulations. Lumbar vertebral HUs (trabecular region) were determined in a standard fashion on axial CT. EP-HU + vertebral HU served as an aggregate bone quality metric. Interbody subsidence (≥2 mm threshold) was directly measured on the endplate-facing surface of 1 year CT scans. Univariate and multivariate analysis compared subsidence based on CT bone metrics. Results A total of 114 patients met the inclusion/exclusion criteria. There was no significant difference in fusion or reoperation rate based on subsidence occurrence. Both vertebral HU ( P = .012) and EP-HU ( P < .001) were associated with subsidence. In receiver operating curves, EP-HU was more optimal for subsidence prediction than vertebral HU, but the aggregate metric further optimized the specificity and total area under the curve. In a predictive logistic regression model EP-HU + vertebral HU (aggregate HU < 515 odds ratio: 7.82, P < .001) was a strong independent predictor of subsidence. Conclusion Preoperative calculation of EP-HUs in addition to vertebral HUs may enhance prediction of TLIF subsidence where aggregate endplate and vertebral HU < 515 can be used to identify high risk patients.
Evaluating longitudinal changes of gait parameters following shunt placement in patients with idiopathic normal pressure hydrocephalus

Journal of Neurosurgery | June 27, 2025 | Volume: 143 | Issue: 5 | Pages: 1254-1261

10.3171/2025.3.jns241416 | PMID 40513237

OBJECTIVE Idiopathic normal pressure hydrocephalus (iNPH) is characterized by gait deterioration, cognitive disturbances, and urinary incontinence. Gait deficits pose safety hazards due to frequent falls, yet objective investigations of gait improvement following ventriculoperitoneal shunt (VPS) placement are limited. Therefore, the aim of this study was to assess objective improvement in gait parameters for patients with iNPH after VPS placement. METHODS All patients treated with a VPS for iNPH by the senior author at a single tertiary care center from December 2017 to January 2023 were retrospectively reviewed. Patients who underwent detailed motion analysis testing before surgery with > 1 follow-up assessment were included. Analyzed parameters included gait velocity, gait cadence, stride length, stride width, gait stability ratio, total support, and single support. Time-dependent linear mixed-effects models and generalized additive mixed-effects models (GAMMs) were used to model short-term and longitudinal gait parameter changes, respectively. RESULTS A total of 212 patients (137 male, median age was 75.2 years) who underwent VPS placement for iNPH were included, with a total of 747 gait analyses performed at a median last-gait analysis follow-up duration of 12.0 months. Statistically significant changes in all gait parameter values were seen between the preoperative time point and first postoperative follow-up (within 3 months) time point (paired Wilcoxon p < 0.001), with a statistically significant majority of patients experiencing improvement (binominal p < 0.0001). Longitudinal analyses using a GAMM showed increased gait velocity, single support, and stride length, with decreased stability ratio, step width, and total support at early time points, while a plateau was achieved around 6 months. CONCLUSIONS A detailed gait analysis demonstrated significant improvements in objective ambulation metrics, particularly in the gait velocity, stride length, and gait stability ratio, following VPS placement in patients with iNPH. Most patients maintained marked improvement from baseline to the last follow-up assessment, although a plateau of the benefit was experienced over longer follow-up.