Background Many devices are used to perform mechanical thrombectomy in the setting of large vessel occlusion acute ischemic stroke. We sought to evaluate the efficacy and safety of pRESET stent-retriever systems. Methods We conducted a comprehensive systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Relevant studies up to March 2024 were retrieved from PubMed, Scopus, Web of Science, and Embase databases. Results A total of 8 papers met the inclusion/exclusion criteria comprising a total of 1140 participants (average age 72.4 ± 11.9, female percentage (50%). Preintervention intravenous thrombolysis was utilized in 46.5% (range 32.9–65.4) of patients, with a median National Institute of Health Stroke Scale at presentation of 15 (range 0–38). The middle cerebral artery was the most commonly affected artery, with a prevalence of 76.4% (range 62.8–100). The pRESET stent-retriever systems demonstrated a first-passing effect rate of 53.4% [95% confidence interval [CI] 44.8; 61.7] and a final thrombolysis in cerebral infarction 2b-3 grade rate of 90.41% [95% CI 82.13; 95.08]. Ninety-day modified Rankin Scale (0–2) rate was 42.2% [95% CI 27.6; 58.4], and 90-day mortality rate was 15.1% [95% CI 9.8; 22.6]. Postintervention hemorrhage occurred at a rate of 28.6% [CI 17.2; 43.6]. Conclusion Our systematic review and meta-analysis describes the efficacy of the pRESET stent retriever system in managing acute ischemic stroke patients. The pRESET device was found to have a similar safety and efficacy profile to other mechanical thrombectomy devices currently in use.
Change in spinal bone mineral density as estimated by Hounsfield units following osteoporosis treatment with romosozumab, teriparatide, denosumab, and alendronate: an analysis of 318 patients
Journal of Neurosurgery: Spine | July 5, 2024 | Volume: 41 | Issue: 3 | Pages: 309-315
OBJECTIVE The purpose of this study was to determine the effect of osteoporosis medications on opportunistic CT-based Hounsfield units (HU). METHODS Spine and nonspine surgery patients were retrospectively identified who had been treated with romosozumab for 3 to 12 months, teriparatide for 3 to 12 months, teriparatide for > 12 months, denosumab for > 12 months, or alendronate for > 12 months. HU were measured in the L1–4 vertebral bodies. One-way ANOVA was used to compare the mean change in HU among the five treatment regimens. RESULTS In total, 318 patients (70% women) were included, with a mean age of 69 years and mean BMI of 27 kg/m 2 . There was a significant difference in mean HU improvement (p < 0.001) following treatment with romosozumab for 3 to 12 months (n = 32), teriparatide for 3 to 12 months (n = 30), teriparatide for > 12 months (n = 44), denosumab for > 12 months (n = 123), and alendronate for > 12 months (n = 100). Treatment with romosozumab for a mean of 10.5 months significantly increased the mean HU by 26%, from a baseline of 85 to 107 (p = 0.012). Patients treated with teriparatide for > 12 months (mean 23 months) experienced a mean HU improvement of 25%, from 106 to 132 (p = 0.039). Compared with the mean baseline HU, there was no significant difference after treatment with teriparatide for 3 to 12 months (110 to 119, p = 0.48), denosumab for > 12 months (105 to 107, p = 0.68), or alendronate for > 12 months (111 to 113, p = 0.80). CONCLUSIONS Patients treated with romosozumab for a mean of 10.5 months and teriparatide for a mean of 23 months experienced improved spinal bone mineral density as estimated by CT-based opportunistic HU. Given the shorter duration of effective treatment, romosozumab may be the preferred medication for optimization of osteoporotic patients in preparation for elective spine fusion surgery.
Injectable bioactive poly(propylene fumarate) and polycaprolactone based click chemistry bone cement for spinal fusion in rabbits
Journal of Biomedical Materials Research Part A | April 22, 2024 | Volume: 112 | Issue: 10 | Pages: 1803-1816
AbstractDegenerative spinal pathology is a widespread medical issue, and spine fusion surgeries are frequently performed. In this study, we fabricated an injectable bioactive click chemistry polymer cement for use in spinal fusion and bone regrowth. Taking advantages of the bioorthogonal click reaction, this cement can be crosslinked by itself eliminating the addition of a toxic initiator or catalyst, nor any external energy sources like UV light or heat. Furthermore, nano‐hydroxyapatite (nHA) and microspheres carrying recombinant human bone morphogenetic protein‐2 (rhBMP‐2) and recombinant human vascular endothelial growth factor (rhVEGF) were used to make the cement bioactive for vascular induction and osteointegration. After implantation into a rabbit posterolateral spinal fusion (PLF) model, the cement showed excellent induction of new bone formation and bridging bone, achieving results comparable to autograft control. This is largely due to the osteogenic properties of nano‐hydroxyapatite (nHA) and the released rhBMP‐2 and rhVEGF growth factors. Since the availability of autograft sources is limited in clinical settings, this injectable bioactive click chemistry cement may be a promising alternative for spine fusion applications in addressing various spinal conditions.
Biodegradable poly(caprolactone fumarate) 3D printed scaffolds for segmental bone defects within the Masquelet technique
Journal of Orthopaedic Research | March 24, 2024 | Volume: 42 | Issue: 9 | Pages: 1974-1983
Abstract Segmental bone defects, often clinically treated with nondegradable poly(methylmethacrylate) (PMMA) in multistage surgeries, present a significant clinical challenge. Our study investigated the efficacy of 3D printed biodegradable polycaprolactone fumarate (PCLF)/PCL spacers in a one‐stage surgical intervention for these defects, focusing on early bone regeneration influenced by spacer porosities. We compared nonporous PCLF/PCL and PMMA spacers, conventionally molded into cylinders, with porous PCLF/PCL spacers, 3D printed to structurally mimic segmental defects in rat femurs for a 4‐week implantation study. Histological analysis, including tissue staining and immunohistochemistry with bone‐specific antibodies, was conducted for histomorphometry evaluation. The PCLF/PCL spacers demonstrated compressive properties within 6 ± 0.5 MPa (strength) and 140 ± 15 MPa (modulus). Both porous PCLF/PCL and Nonporous PMMA formed collagen‐rich membranes (PCLF/PCL: 92% ± 1.3%, PMMA: 86% ± 1.5%) similar to those induced in the Masquelet technique, indicating PCLF/PCL's potential for one‐stage healing. Immunohistochemistry confirmed biomarkers for tissue regeneration, underscoring PCLF/PCL's regenerative capabilities. This research highlights PCLF/PCL scaffolds' ability to induce membrane formation in critical‐sized segmental bone defects, supporting their use in one‐stage surgery. Both solid and porous PCLF/PCL spacers showed adequate compressive properties, with the porous variants exhibiting BMP‐2 expression and woven bone formation, akin to clinical standard PMMA. Notably, the early ossification of the membrane into the pores of porous scaffolds suggests potential for bone interlocking and regeneration, potentially eliminating the need for a second surgery required for PMMA spacers. The biocompatibility and biodegradability of PCLF/PCL make them promising alternatives for treating critical bone defects, especially in vulnerable patient groups.
Bioactive Moldable Click Chemistry Polymer Cement with Nano-Hydroxyapatite and Growth Factor-Enhanced Posterolateral Spinal Fusion in a Rabbit Model
ACS Applied Bio Materials | March 19, 2024 | Volume: 7 | Issue: 4 | Pages: 2450-2459
Significant Reduction in Bone Density as Measured by Hounsfield Units in Patients with Ankylosing Spondylitis or Diffuse Idiopathic Skeletal Hyperostosis
Journal of Clinical Medicine | March 1, 2024 | Volume: 13 | Issue: 5 | Pages: 1430
Background: Multisegmental pathologic autofusion occurs in patients with ankylosing spondylitis (AS) and diffuse idiopathic skeletal hyperostosis (DISH). It may lead to reduced vertebral bone density due to stress shielding. Methods: This study aimed to determine the effects of autofusion on bone density by measuring Hounsfield units (HU) in the mobile and immobile spinal segments of patients with AS and DISH treated at a tertiary care center. The mean HU was calculated for five distinct regions—cranial adjacent mobile segment, cranial fused segment, mid-construct fused segment, caudal fused segment, and caudal adjacent mobile segment. Means for each region were compared using paired-sample t-tests. Multivariable regression was used to determine independent predictors of mid-fused segment HUs. Results: One hundred patients were included (mean age 76 ± 11 years, 74% male). The mean HU for the mid-construct fused segment (100, 95% CI [86, 113]) was significantly lower than both cranial and caudal fused segments (174 and 108, respectively; both p < 0.001), and cranial and caudal adjacent mobile segments (195 and 115, respectively; both p < 0.001). Multivariable regression showed the mid-construct HUs were predicted by history of smoking (−30 HU, p = 0.009). Conclusions: HUs were significantly reduced in the middle of long-segment autofusion, which was consistent with stress shielding. Such shielding may contribute to the diminution of vertebral bone integrity in AS/DISH patients and potentially increased fracture risk.
The Predictors of Incidental Durotomy in Patients Undergoing Pedicle Subtraction Osteotomy for the Correction of Adult Spinal Deformity
Journal of Clinical Medicine | January 8, 2024 | Volume: 13 | Issue: 2 | Pages: 340
Background: Pedicle subtraction osteotomy (PSO) is a powerful tool for sagittal plane correction in patients with rigid adult spinal deformity (ASD); however, it is associated with high intraoperative blood loss and the increased risk of durotomy. The objective of the present study was to identify intraoperative techniques and baseline patient factors capable of predicting intraoperative durotomy. Methods: A tri-institutional database was retrospectively queried for all patients who underwent PSO for ASD. Data on baseline comorbidities, surgical history, surgeon characteristics and intraoperative maneuvers were gathered. PSO aggressiveness was defined as conventional (Schwab 3 PSO) or an extended PSO (Schwab type 4). The primary outcome of the study was the occurrence of durotomy intraoperatively. Univariable analyses were performed with Mann–Whitney U tests, Chi-squared analyses, and Fisher’s exact tests. Statistical significance was defined by p < 0.05. Results: One hundred and sixteen patients were identified (mean age 61.9 ± 12.6 yr; 44.8% male), of whom 51 (44.0%) experienced intraoperative durotomy. There were no significant differences in baseline comorbidities between those who did and did not experience durotomy, with the exception that baseline weight and body mass index were higher in patients who did not suffer durotomy. Prior surgery (OR 2.73; 95% CI [1.13, 6.58]; p = 0.03) and, more specifically, prior decompression at the PSO level (OR 4.23; 95% CI [1.92, 9.34]; p < 0.001) was predictive of durotomy. A comparison of surgeon training showed no statistically significant difference in durotomy rate between fellowship and non-fellowship trained surgeons, or between orthopedic surgeons and neurosurgeons. The PSO level, PSO aggressiveness, the presence of stenosis at the PSO level, nor the surgical instrument used predicted the odds of durotomy occurrence. Those experiencing durotomy had similar hospitalization durations, rates of reoperation and rates of nonroutine discharge. Conclusions: In this large multisite series, a history of prior decompression at the PSO level was associated with a four-fold increase in intraoperative durotomy risk. Notably the use of extended (versus) standard PSO, surgical technique, nor baseline patient characteristics predicted durotomy. Durotomies occurred in 44% of patients and may prolong operative times. Additional prospective investigations are merited.
Opportunistic CT-Based Hounsfield Units Strongly Correlate with Biomechanical CT Measurements in the Thoracolumbar Spine
Study Design. Retrospective cohort study. Objective. Hounsfield units (HUs) are known to correlate with clinical outcomes, but no study has evaluated how they correlate with biomechanical computed tomography (BCT) and dual-energy x-ray absorptiometry (DXA) measurements. Summary of Background. Low bone mineral density (BMD) represents a major risk factor for fracture and poor outcomes following spine surgery. DXA can provide regional BMD measurements but has limitations. Opportunistic HUs provide targeted BMD estimates; however, they are not formally accepted for diagnosing osteoporosis in current guidelines. More recently, BCT analysis has emerged as a new modality endorsed by the International Society for Clinical Densitometry for assessing bone strength. Methods. Consecutive cases from 2017 to 2022 at a single institution were reviewed for patients who underwent BCT in the thoracolumbar spine. BCT-measured vertebral strength, trabecular BMD, and the corresponding American College of Radiology Classification were recorded. DXA studies within three months of the BCT were reviewed. Pearson Correlation Coefficients were calculated, and receiver-operating characteristic curves were constructed to assess the predictive capacity of HUs. Threshold analysis was performed to identify optimal HU values for identifying osteoporosis and low BMD. Results. Correlation analysis of 114 cases revealed a strong relationship between HUs and BCT vertebral strength (r=0.69; P<0.0001; R 2=0.47) and trabecular BMD (r=0.76; P<0.0001; R 2=0.58). However, DXA poorly correlated with opportunistic HUs and BCT measurements. HUs accurately predicted osteoporosis and low BMD (Osteoporosis: C=0.95, 95% CI 0.89–1.00; Low BMD: C=0.87, 95% CI 0.79–0.96). Threshold analysis revealed that 106 and 122 HUs represent optimal thresholds for detecting osteoporosis and low BMD. Conclusion. Opportunistic HUs strongly correlated with BCT-based measures, while neither correlated strongly with DXA-based BMD measures in the thoracolumbar spine. HUs are easy to perform at no additional cost and provide accurate BMD estimates at noninstrumented vertebral levels across all American College of Radiology-designated BMD categories.