Citations 93

Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 | PMID 34911151

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
57. Evaluation of the 2019 European Heart Rhythm Association International Consensus Document in Patients with Cardiovascular Implantable Electronic Devices Who Develop Staphylococcus aureus Bacteremia

Open Forum Infectious Diseases | December 5, 2021 | Volume: 8 | Issue: Supplement_1 | Pages: S40-S40

10.1093/ofid/ofab466.057

Abstract Background Cardiovascular implantable electronic device (CIED) implantation has markedly increased over the past two decades. Staphylococcus aureus bacteremia (SAB) occurs in patients with CIED and determination of device infection among patients without clinical findings of pocket site infection is often difficult. Our study examines the characteristics, management, and outcomes of SAB in patients living with CIED using 2019 international criteria to define CIED infection. Methods We conducted a retrospective study of patients with CIED who were hospitalized at Mayo Clinic, Rochester, with SAB from January 1, 2012 to December 31, 2019. Patients who met CIED infection criteria following SAB based on the 2019 European Heart Rhythm Association International Concensus Document were identified. A time-to-event analysis was used to determine the impact, if any, of complete device extraction on outcomes. Results Overall, 110 patients with CIED developed SAB and 92 (83.6%) of them underwent transesophageal echocardiogram (TEE). Eighty-eight (80%) had CIED infection with 57 (51.8%) and 31 (28.2%) patients meeeting criteria for definite and possible CIED infections, respectively. Forty-three (75.4%) patients with definite CIED infection underwent complete device extraction. For possible and rejected CIED infection, the rates of complete device extraction were 35.5% and 27.3%, respectively (p< .001 for each). The primary endpoint of a composite of one-year mortality and SAB relapse had a rate that was significantly lower in patients with CIED infection who underwent complete device extraction as compared to that of patients who did not undergo device extraction (25.9% vs. 76.5%, p< .001). No significant difference in outcomes was seen in the rejected CIED infection group (33.3% vs. 62.5%, p =.27). Conclusion The rate of CIED infections following SAB was higher than that reported previously. Increased use of TEE and a novel case definition with broader diagnostic criteria were likely operative, in part, in accounting for the the higher rate of CIED infections complicating SAB. Complete device removal is critical in patients with either definite or possible CIED infection as defined by the 2019 consensus document to improve one-year mortality and SAB relapse rates. Disclosures Larry M. Baddour, MD, Boston Scientific (Individual(s) Involved: Self): Consultant; Botanix Pharmaceuticals (Individual(s) Involved: Self): Consultant; Roivant Sciences (Individual(s) Involved: Self): Consultant Muhammad R. Sohail, MD, Medtronic (Consultant)Philips (Consultant)
Device‐detected nonsustained ventricular tachycardia in adult congenital heart disease without tetralogy of fallot

Pacing and Clinical Electrophysiology | December 1, 2021 | Volume: 45 | Issue: 3 | Pages: 302-313

10.1111/pace.14420 | PMID 34856638

AbstractObjectivesTo evaluate any association between non‐sustained ventricular tachycardia (NSVT) detected by intra‐cardiac device and clinical outcomes in repaired adult congenital heart disease (ACHD) without tetralogy of Fallot (TOF).BackgroundNSVT portends a higher risk of serious ventricular tachyarrhythmia in TOF. However its clinical significance when incidentally detected by implantable cardiac device is not well elucidated in non‐TOF ACHD cohort.MethodsWe performed a single center, retrospective, longitudinal follow‐up study in repaired ACHD (≥18 years) patients without TOF who hosted a pacemaker or automatic implantable cardiac defibrillator (AICD). The cohort was divided based on presence/absence of device detected NSVT. The primary end‐point was a composite of sustained ventricular tachycardia (VT), ventricular fibrillation (VF), or sudden cardiac death (SCD).ResultsOne hundred fifty eight patients (male 56.3%, median [IQR] age of 35 [28–43] years at last follow‐up] with longitudinal post‐implant follow‐up duration of 8 (5–12) years were included. NSVT was detected in 52 (33%) patients. The primary composite end‐point was more frequent in NSVT group [11.5% vs. 2.8%; p = .04]. Patients with NSVT were (i) older at the time of initial implant (age 25 vs. 18 years, p = .011) and more frequently demonstrated (ii) systemic ventricular dysfunction (44% vs. 26%; p = .015), as well as (iii) history of ventriculotomy (38% vs. 21%; p = .017).ConclusionsIn our repaired ACHD cohort, we noted a significant association between device‐detected‐NSVT and the primary composite end‐point of sustained VT/VF or SCD. Systemic ventricular dysfunction and history of ventriculotomy were more frequent in the NSVT group and likely constituted the clinical milieu.
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 | PMID 34664765

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Abstract 44: Associations of Atrial Fibrillation, Neuroimaging Measures of Cerebrovascular Disease and Alzheimer’S Disease-related Pathology, and Cognitive Impairment

Stroke | July 3, 2021 | Volume: 46 | Issue: suppl_1 | Pages: No page available

10.1161/str.46.suppl_1.44

The objective of this study was to investigate the cross-sectional associations of atrial fibrillation with neuroimaging measures of cerebrovascular disease and Alzheimer’s disease-related pathology, and their interaction with cognitive impairment. MRI scans of non-demented individuals (n=1044) from the population-based Mayo Clinic Study of Aging were analyzed for infarctions, total grey matter, hippocampal and white matter hyperintensity volumes. A subset of 496 individuals underwent FDG and C-11 Pittsburgh compound B (PiB) PET scans. We assessed the associations of atrial fibrillation with i) categorical MRI measures (cortical and subcortical infarctions) using multivariable logistic regression models, and with ii) continuous MRI measures ( hippocampal, total grey matter, and white matter hyperintensity volumes) and FDG-PET and PiB-PET measures using multivariable linear regression models, and adjusting for confounders. Among participants who underwent MRI (median age, 77.8, 51.6% male), 13.5% had atrial fibrillation. Presence of atrial fibrillation was associated with subcortical infarctions (odds ratio [OR], 1.83; p=0.002), cortical infarctions (OR, 1.91; p=0.03), total grey matter volume (Beta [β], -.025, p<.0001) after controlling for age, education, gender, APOE e4 carrier status, coronary artery disease, diabetes, history of clinical stroke, and hypertension. However, atrial fibrillation was not associated with white matter hyperintensity volume, hippocampal volume, Alzheimer’s pattern of FDG hypometabolism or PiB uptake. There was a significant interaction of cortical infarction (p for interaction=0.004) and subcortical infarction (p for interaction =0.015) with atrial fibrillation with regards to odds of mild cognitive impairment (MCI). Using subjects with no atrial fibrillation and no infarction as the reference, the OR (95% confidence intervals [CI]) for MCI was 2.98 (1.66, 5.35;p = 0.0002) among participants with atrial fibrillation and any infarction, 0.69 (0.36, 1.33;p= 0.27) for atrial fibrillation and no infarction, and 1.50 (0.96, 2.32;p = 0.07) for no atrial fibrillation and any infarction. These data highlight that atrial fibrillation is associated with MCI in the presence of infarctions.
Characteristics and Outcomes of Ventricular Tachycardia and Premature Ventricular Contractions Ablation in Patients with Prior Mitral Valve Surgery

No container title available | July 2, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162524921.19356960/v1

Background: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following MVS is limited.) CA can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. Objective: To investigate the characteristics, safety, and outcomes of radiofrequency catheter ablation (CA) in patients with prior mitral valve surgery (MVS) and ventricular arrhythmias (VA). Methods: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013- December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. Results: In our cohort of 31 patients (77% men, mean age 62.3±10.8 years, left ventricular ejection fraction 39.2±13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in 1patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Clinical VA substrates involved the peri-mitral area in 6 patients with VT and 5 patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. Conclusion: CA of VAs can be performed safely and effectively in patients with MVS
Catheter ablation of premature ventricular contractions originating from periprosthetic aortic valve regions

Journal of Cardiovascular Electrophysiology | December 11, 2020 | Volume: 32 | Issue: 2 | Pages: 400-408

10.1111/jce.14836 | PMID 33305865

AbstractBackgroundLittle is known about the ablation outcomes of premature ventricular contractions (PVCs) that originate from the periprosthetic aortic valve (PPAV) regions of patients with aortic valve replacement (AVR).Methods and ResultsOur study had 11 patients who underwent catheter ablation for PVCs arising from the PPAV regions (bioprosthetic aortic valve, n = 5; mechanical aortic valve, n = 6). The PVC characteristics, procedure characteristics, and efficacy of ablation were compared with the control group (n = 33). At baseline, the PPAV group had a lower left ventricular ejection fraction (mean [SD], 41% [12%] vs. 51% [8%]; p = .002). The rate of acute ablation success was 90.9% in the PPAV group. Ablation sites were identified above the left coronary cusp (LCC) and right coronary cusp commissure (LRCC) in one PVC, below the prosthetic valve in eight PVCs (four below LCC and four below LRCC), and within the distal coronary sinus in two PVCs. The mean procedure time, fluoroscopy time, and radiation in the PPAV group were all significantly greater than those in the control group (all p < .05). However, the number of radiofrequency ablation energy deliveries was not different. The PPAV group had a long‐term success rate compared with the control group (72.7% vs. 87.9%, p = .48) and an increase of left ventricular ejection fraction from 43% to 49% after successful PVC ablation at follow‐up (p < .001). Echocardiography showed no significant change in valve regurgitation after ablation. No new atrioventricular block occurred.ConclusionPVCs arising from PPAV regions can be successfully ablated in patients with prior AVR, without damaging the prosthetic aortic valve and atrioventricular conduction.
Sound wave balloon-assisted device implantation: a novel approach that merits consideration

EP Europace | November 19, 2020 | Volume: 23 | Issue: 5 | Pages: 747-747

10.1093/europace/euaa281 | PMID 33582813

Characterization of Lesions Created by a Heated, Saline Irrigated Needle-Tip Catheter in the Normal and Infarcted Canine Heart

Circulation: Arrhythmia and Electrophysiology | November 17, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.009090 | PMID 33198498

Background: Inability to eliminate intramural arrhythmogenic substrate may lead to recurrent ventricular tachycardia after catheter ablation. The aim of the present study was to evaluate intramural and full thickness lesion formation using a heated saline-enhanced radiofrequency (SERF) needle-tip catheter, compared with a conventional ablation catheter in normal and infarcted myocardium. Methods: Twenty-two adult mongrel dogs (30–40 kg, 15 normal and 7 myocardial infarct group) were studied. Lesions were created using the SERF catheter (40 W/50 °C) or a standard contact force (CF) catheter in both groups. Results: Comparing SERF to CF ablation, the SERF catheter produced larger lesion volumes than the standard CF catheter—even with >20 g of CF—in both normal (983.1±905.8 versus 461.9±178.3 mm 3 ; P =0.023) and infarcted left ventricular myocardium (1052.3±543.0 versus 340.3±160.5 mm 3 ; P =0.001). SERF catheter lesions were more often transmural than standard CF lesions with >20 g of CF in both groups (59.1% versus 7.7%; P <0.001 and 60.0% versus 12.5%; P =0.017, respectively). Using the SERF catheter, mean depth of ablated lesions reached 90% of the left ventricular wall in both normal and infarcted myocardium. Conclusions: The SERF catheter created more transmural and larger ablative lesions in both normal and infarcted canine myocardium. SERF ablation is a promising new approach for endocardial intramural and full thickness ablation of ventricular tachycardia substrate that is not accessible with current techniques.