Citations 4

Automated Insulin Delivery Is Beneficial in Adults With Insulin-Treated Type 2 Diabetes With and Without GAD65 Antibodies

Diabetes Care | December 5, 2025 | Volume: 49 | Issue: 2 | Pages: e18-e20

10.2337/dc25-2059 | PMID 41348329

Adults With Type 2 Diabetes Benefit From Automated Insulin Delivery Irrespective of C-Peptide Level

Diabetes Care | September 15, 2025 | Volume: 48 | Issue: 12 | Pages: 2061-2066

10.2337/dc25-1125 | PMID 40953318

OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes

New England Journal of Medicine | March 19, 2025 | Volume: 392 | Issue: 18 | Pages: 1801-1812

10.1056/nejmoa2415948 | PMID 40105270

A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials

Journal of Diabetes Science and Technology | August 18, 2023 | Volume: 17 | Issue: 6 | Pages: 1527-1552

10.1177/19322968231191104 | PMID 37592726

Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.