Citations 188

Normal-Weight Central Obesity: Implications for Total and Cardiovascular Mortality

Annals of Internal Medicine | November 9, 2015 | Volume: 163 | Issue: 11 | Pages: 827-835

10.7326/m14-2525 | PMID 26551006

Small (< 4 cm) Renal Mass: Differentiation of Oncocytoma From Renal Cell Carcinoma on Biphasic Contrast-Enhanced CT

American Journal of Roentgenology | October 24, 2015 | Volume: 205 | Issue: 5 | Pages: 999-1007

10.2214/ajr.14.13966 | PMID 26496547

Evaluation of Posttreatment Follow-Up of Patients With Prostate Cancer Relative to the American College of Radiology's Appropriateness Criteria

American Journal of Roentgenology | October 24, 2015 | Volume: 205 | Issue: 5 | Pages: 1008-1015

10.2214/ajr.14.13766 | PMID 26496548

Nocturnal Glucose Metabolism in Type 1 Diabetes: A Study Comparing Single Versus Dual Tracer Approaches

Diabetes Technology & Therapeutics | June 29, 2015 | Volume: 17 | Issue: 8 | Pages: 587-595

10.1089/dia.2015.0011 | PMID 26121060

Background: Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). Subjects and Methods: We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump therapy for two successive nights. Endogenous glucose production (EGP) rates at 3 a.m. and 7 a.m. were measured with [6,6- 2 H 2 ]glucose as a single tracer, infused from midnight to 7 a.m. in all subjects. To explore possibility of tracer recycling due to prolonged [6,6- 2 H 2 ]glucose infusion, which was highly probable after preplanned interim data analyses, we infused a second tracer, [6- 3 H]glucose, from 4 a.m. to 7 a.m. in the last seven subjects to measure EGP at 7 a.m. Results: Cortisol concentrations increased during both nights, but changes in glucagon and insulin concentration were inconsistent. Although the plasma glucose concentrations rose from midnight to 7 a.m. during both nights, EGP measured with [6,6- 2 H 2 ]glucose between 3 a.m. and 7 a.m. did not differ during Night 1 but fell in Night 2. However, EGP measured with [6- 3 H]glucose at 7 a.m. was higher than that measured with [6,6- 2 H 2 ]glucose during both nights, thereby suggesting tracer recycling probably underestimating EGP calculated at 7 a.m. with [6,6- 2 H 2 ]glucose. Likewise, EGP was higher at 7 a.m. with [6- 3 H]glucose than at 3 a.m. with [6,6- 2 H 2 ]glucose during both nights. Conclusions: The data demonstrate a consistent overnight rise in glucose concentrations through increased EGP, mediated likely by rising cortisol concentrations. The observations with the dual tracer approach imply significant tracer recycling leading to underestimation of EGP measured by longer-duration tracer infusion.
Variability and accuracy of different software packages for dynamic susceptibility contrast magnetic resonance imaging for distinguishing glioblastoma progression from pseudoprogression

Journal of Medical Imaging | May 26, 2015 | Volume: 2 | Issue: 2 | Pages: 026001

10.1117/1.jmi.2.2.026001 | PMID 26158114

Background Parenchymal Uptake During Molecular Breast Imaging and Associated Clinical Factors

American Journal of Roentgenology | February 25, 2015 | Volume: 204 | Issue: 3 | Pages: W363-W370

10.2214/ajr.14.12979 | PMID 25714323

Retrospective Analysis of Interobserver Spatial Variability in the Localization of Broca's and Wernicke's Areas Using Three Different fMRI Language Paradigms

Journal of Neuroimaging | December 13, 2014 | Volume: 25 | Issue: 4 | Pages: 626-633

10.1111/jon.12179 | PMID 25496329

ABSTRACTPURPOSETo determine interobserver spatial variability in language area localization using three commonly employed language tasks.MATERIALS AND METHODSWith institutional review board approval, 125 fMRI time series from 50 different clinical language cases were retrospectively reviewed by three blinded readers who selected 3‐dimensional points representing the perceived center of Wernicke's and Broca's areas using three language tasks (semantic decision, SD; sentence comprehension, SC; and silent word generation, WG). Point dispersion values were then calculated using the perimeter of the 3‐dimensional triangle defined by the three readers’ selections.RESULTSAfter resolving interobserver laterality disagreements, there was no difference in spatial variability between the three tasks (P = .069). The SD task had the fewest interobserver laterality disagreements (P = .028) and the SC task had fewer failed localizations for Broca's area (P = .050) and Wernicke's area (P = .013).CONCLUSIONWhile there were no differences between interobserver spatial variability in language area localization between the three tasks, language task choice impacts the accuracy of fMRI language area identification because tasks vary in their rates of interobserver laterality disagreements and failed localizations. A combination of tasks including one with low laterality disagreements (eg, SD) and one with few failed localizations (eg, SC) may offer the best combination.
Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes

Journal of Diabetes Science and Technology | October 11, 2014 | Volume: 9 | Issue: 1 | Pages: 63-68

10.1177/1932296814554797 | PMID 25305282

Background and Objective: The premise of effective closed-loop insulin therapy for type 1 diabetes (T1D) relies on the accuracy of continuous interstitial fluid glucose sensing that represents the crucial afferent arm of such a system. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. The purpose of current studies was to determine the physiological time lag of glucose transport from the vascular to the abdominal subcutaneous interstitial space in T1D. Method: Four microdialysis catheters were inserted into the abdominal subcutaneous space in 6 T1D subjects under overnight fasted conditions. Plasma glucose was maintained at 113.7 ± 6.3 mg/dl using a continuous intravenous insulin infusion. After sequential intravenous bolus administrations of glucose isotopes, timed plasma and interstitial fluid samples were collected chronologically and analyzed for tracer enrichments. Results: We observed a median (range) time lag of tracer appearance (time to detection) into the interstitial space after intravenous bolus of 6.8 (4.8-9.8) minutes, with all participants having detectable values by 9.8 minutes. Conclusions: We conclude that in the overnight fasted state in T1D adults, the delay of glucose appearance from the vascular to the interstitial space is less than 10 minutes, thereby implying that this minimal physiological time lag should not be a major impediment to the development of an effective closed-loop control system for T1D.
Assessing Statistical Competencies in Clinical and Translational Science Education: One Size Does Not Fit All

Clinical and Translational Science | September 12, 2014 | Volume: 8 | Issue: 1 | Pages: 32-42

10.1111/cts.12204 | PMID 25212569

Effects of delayed gastric emptying on postprandial glucose kinetics, insulin sensitivity, and β-cell function

American Journal of Physiology-Endocrinology and Metabolism | July 30, 2014 | Volume: 307 | Issue: 6 | Pages: E494-E502

10.1152/ajpendo.00199.2014 | PMID 25074985

Controlling meal-related glucose excursions continues to be a therapeutic challenge in diabetes mellitus. Mechanistic reasons for this need to be understood better to develop appropriate therapies. To investigate delayed gastric emptying effects on postprandial glucose turnover, insulin sensitivity, and β-cell responsivity and function, as a feasibility study prior to studying patients with type 1 diabetes, we used the triple tracer technique C-peptide and oral minimal model approach in healthy subjects. A single dose of 30 μg of pramlintide administered at the start of a mixed meal was used to delay gastric emptying rates. With delayed gastric emptying rates, peak rate of meal glucose appearance was delayed, and rate of endogenous glucose production (EGP) was lower. C-peptide and oral minimal models enabled the assessments of β-cell function, insulin sensitivity, and β-cell responsivity simultaneously. Delayed gastric emptying induced by pramlintide improved total insulin sensitivity and decreased total β-cell responsivity. However, β-cell function as measured by total disposition index did not change. The improved whole body insulin sensitivity coupled with lower rate of appearance of EGP with delayed gastric emptying provides experimental proof of the importance of evaluating pramlintide in artificial endocrine pancreas approaches to reduce postprandial blood glucose variability in patients with type 1 diabetes.