Citations 39

Strategy for analysis of flow diverting devices based on multi‐modality image‐based modeling

International Journal for Numerical Methods in Biomedical Engineering | April 9, 2014 | Volume: 30 | Issue: 10 | Pages: 951-968

10.1002/cnm.2638 | PMID 24719392

SUMMARY Quantification and characterization of the hemodynamic environment created after flow diversion treatment of cerebral aneurysms is important to understand the effects of flow diverters and their interactions with the biology of the aneurysm wall and the thrombosis process that takes place subsequently. This paper describes the construction of multi‐modality image‐based subject‐specific CFD models of experimentally created aneurysms in rabbits and subsequently treated with flow diverters. Briefly, anatomical models were constructed from 3D rotational angiography images, flow conditions were derived from Doppler ultrasound measurements, stent models were created and virtually deployed, and the results were compared with in vivo digital subtraction angiography and Doppler ultrasound images. The models were capable of reproducing in vivo observations, including velocity waveforms measured in the parent artery, peak velocity values measured in the aneurysm, and flow structures observed with digital subtraction angiography before and after deployment of flow diverters. The results indicate that regions of aneurysm occlusion after flow diversion coincide with slow and smooth flow patterns, whereas regions still permeable at the time of animal sacrifice were observed in parts of the aneurysm exposed to larger flow activity, that is, higher velocities, more swirling, and more complex flow structures. Copyright © 2014 John Wiley & Sons, Ltd.
CFD Study of the Relationship Between Wall Shear Stress and Aspect Ratio in Elastase Induced Rabbit Aneurysm Models

ASME 2008 Summer Bioengineering Conference, Parts A and B | March 13, 2014 | Volume: No volume available | Issue: No issue available | Pages: 35-36

10.1115/sbc2008-193139

Hemodynamic factors are thought to play an important role in the initiation, growth, and rupture of cerebral aneurysms. In-vitro studies have demonstrated a correlation between the magnitude and distribution of wall shear stress (WSS) and biological response of both endothelial cells and smooth muscle cells [1–3]. In elastase induced saccular aneurysms, low WSS (below 0.5 Pa) was found to have a correlation with altered expression of biological markers [4]. Localized regions of rapid aneurysm growth in-vivo have been shown to be associated with regions where WSS is below a critical value of 0.1 Pa [5]. Further, aspect ratio (AR), the ratio of the maximum diameter of the aneurysm to the width of the aneurysm neck, has been correlated with elevated risk of rupture [6]. The purpose of the current study is to explore the possibility of creating elastase induced aneurysms in rabbits with a range of aspect ratios (ratio of aneurysm height/neck) and evaluate the existence of a correlation between aspect ratio and WSS distribution. Aneurysms with ARs from 0.98 to 2.8 were created at the origin of the right common carotid artery (n = 30). Qualitative differences in WSS distribution were found in the high AR aneurysms (HARA) (AR>1.6) and low AR aneurysms (LARA) (AR<1.6) [7].
Hemodynamics of Elastase-Induced Aneurysms in Rabbit: A New High Flow Bifurcation Model

ASME 2011 Summer Bioengineering Conference, Parts A and B | July 17, 2013 | Volume: No volume available | Issue: No issue available | Pages: 267-268

10.1115/sbc2011-53819

An intracranial aneurysm (IA) is a pathological condition of cerebral arteries characterized by local enlargements of the arterial wall, typically into a saccular shape. Rupture of the aneurysm sac can result in devastating cerebral hemorrhage. Hemodynamic factors are believed to play an important role in initiation, development and rupture of IAs [1–3]. However, the coupling between hemodynamics and aneurysm pathophysiology is complex and remains poorly understood. Patient specific diagnostics regarding risk of rupture can be substantially advanced by improving our understanding of the in-vivo response of the aneurysm wall to intra-saccular hemodynamic stresses. A mechanism for fundamental studies of the impact of chronically altered WSS on the intact vascular wall is provided by animal models. However, cerebral aneurysms have not been shown to occur naturally in animals. Thus, a number of animal models have been created for studying aneurysm pathogenesis including those in mice, rats, rabbits, canines, swine and primates. To make meaningful use of these models, it is important to evaluate their relevance to human biomechanics and pathophysiology.
Sensitivity of CFD Based Hemodynamic Results in Rabbit Aneurysm Models to Idealizations in Surrounding Vasculature

Journal of Biomechanical Engineering | April 26, 2010 | Volume: 132 | Issue: 9 | Pages: No page available

10.1115/1.4001311 | PMID 20815643

Computational fluid dynamics (CFD) studies provide a valuable tool for evaluating the role of hemodynamics in vascular diseases such as cerebral aneurysms and atherosclerosis. However, such models necessarily only include isolated segments of the vasculature. In this work, we evaluate the influence of geometric approximations in vascular anatomy on hemodynamics in elastase induced saccular aneurysms in rabbits. One representative high aspect ratio (AR—height/neck width) aneurysm and one low AR aneurysm were created at the origin of the right common carotid artery in two New Zealand white rabbits. Three-dimensional (3D) reconstructions of the aneurysm and surrounding arteries were created using 3D rotational angiographic data. Five models with varying extents of neighboring vasculature were created for both the high and low AR cases. A reference model included the aneurysm sac, left common carotid artery (LCCA), aortic arch, and downstream trifurcation/quadrification. Three-dimensional, pulsatile CFD studies were performed and streamlines, wall shear stress (WSS), oscillatory shear index, and cross sectional velocity were compared between the models. The influence of the vascular domain on intra-aneurysmal hemodynamics varied between the low and high AR cases. For the high AR case, even a simple model including only the aneurysm, a small section of neighboring vasculature, and simple extensions captured the main features of the steamline and WSS distribution predicted by the reference model. However, the WSS distribution in the low AR case was more strongly influenced by the extent of vasculature. In particular, it was necessary to include the downstream quadrification and upstream LCCA to obtain good predictions of WSS. The findings in this work demonstrate the accuracy of CFD results can be compromised if insufficient neighboring vessels are included in studies of hemodynamics in elastase induced rabbit aneurysms. Consideration of aspect ratio, hemodynamic parameters of interest, and acceptable magnitude of error when selecting the vascular domain will increase reliability of the results while decreasing computational time.
Change in Diffusion-Weighted Imaging Infarct Volume Predicts Neurologic Outcome at 90 Days

Stroke | May 15, 2009 | Volume: 40 | Issue: 7 | Pages: 2422-2427

10.1161/strokeaha.109.548933 | PMID 19443798

Background and Purpose— Predictive models of outcome after ischemic stroke have incorporated acute diffusion-weighted MRI (DWI) information with mixed results. We hypothesized that serial measurements of DWI infarct volume would be predictive of functional outcome after ischemic stroke. Methods— The prospective Acute Stroke Accurate Prediction (ASAP) Study included a prespecified serial imaging subgroup who underwent DWI studies at baseline (<24 hours after symptom onset) and Day 5 (±2 days). DWI infarct volumes were calculated using the Analyze software (Rochester, Minn). Clinical outcomes were assessed at 3 months. Univariate and multivariable regression analysis was performed to assess the relationship between change in DWI lesion volume and excellent neurological outcome (modified Rankin Scale 0, 1, and Barthel Index ≥95). Results— In total, 169 cases from the ASAP study had serial DWI scans with a measurable lesion at baseline, follow-up, or both. The median baseline National Institutes of Health Stroke Scale score was 6 (interquartile range, 3 to 13). For each 10 cm 3 of growth in DWI infarct volume, the OR for achieving an excellent outcome by modified Rankin Scale was 0.52 (95% CI, 0.38 to 0.71) and for the Barthel Index was 0.64 (95% CI, 0.51 to 0.79). Adjusting for clinically important covariates, the OR for an excellent modified Rankin Scale outcome was 0.57 (95% CI, 0.37 to 0.88) and excellent Barthel Index outcome was 0.75 (95% CI, 0.56 to 1.01). Conclusions— Based on these data, the likelihood of achieving an excellent neurological outcome diminishes substantially with growth in DWI infarct volume in the first 5 days after ischemic stroke of mild to moderate severity.
Clinical and Imaging Data at 5 Days as a Surrogate for 90-Day Outcome in Ischemic Stroke

Stroke | February 20, 2009 | Volume: 40 | Issue: 4 | Pages: 1332-1333

10.1161/strokeaha.108.528976 | PMID 19228853

Background and Purpose— A simple, easily measured surrogate outcome measure for use in early treatment trials for acute ischemic stroke therapies would be highly valued. We hypothesized that day-5 NIH stroke scale score (NIHSS) and day-5 diffusion weighted imaging (DWI) volume would predict clinical outcome better than either alone and could be considered as a possible surrogate outcome in early phase acute stroke trials. Methods— The prospective Acute Stroke Accurate Prediction (ASAP) trial included a prespecified subgroup evaluated for early outcome. Logistic regression analysis was used to assess the prediction of modified Rankin (mRankin) of 0 or 1. Results— A total of 204 subjects completed the substudy, and 116 (57%) had excellent outcome at 3 months. The area under the ROC curve (AUC) for day-5 NIHSS predicting 3-month excellent outcome was 0.84; for DWI volume predicting outcome was 0.76, and for the multivariable model combining both was 0.84. Conclusions— The results of the early outcome substudy of the ASAP trial suggest that early stroke severity and infarct volume measures are predictive of 3-month excellent outcome. In our data set the DWI volume does not add clinically relevant information in predicting 3-month outcome. Validation of these results is required.
Molecular Indices of Apoptosis Activation in Elastase-Induced Aneurysms After Embolization With Platinum Coils

Stroke | August 24, 2007 | Volume: 38 | Issue: 10 | Pages: 2787-2794

10.1161/strokeaha.107.486738 | PMID 17717314

Background and Purpose— Even though endovascular coils have been widely used for the treatment of intracranial aneurysms, the cellular and molecular responses of aneurysms to the coils after embolization remain poorly understood. The aim of the present study was to understand the mechanism of apoptosis in aneurysms embolized with platinum coils in the rabbit model of elastase-induced aneurysms. Methods— Elastase-induced saccular aneurysms were created at the origin of the right common carotid artery in 30 rabbits. Aneurysms were allowed to mature for 8 weeks, after which 20 aneurysms were embolized with platinum coils by endovascular means. After 2 (n=10) and 4 (n=10) weeks of implantation, aneurysm samples harboring coils were harvested for apoptotic studies. The remaining 10 uncoiled aneurysms were used as controls; additional controls included the left common carotid artery, which had not undergone any surgical procedure. Control samples were harvested at 12 weeks after aneurysm creation. Results— Expression of procaspases-3, -8, and -9 was elevated in coiled aneurysms embolized with platinum coils at both time points when compared with uncoiled aneurysms and the left common carotid artery. Cleaved caspases-3, -8, and -9 were found to be expressed only at 4 weeks after embolization. Cells within the aneurysm cavity were terminal dUTP nick end-labeling–positive at 4 weeks only. These apoptotic cells were identified as smooth muscle actin–positive cells. Expression of tumor necrosis-α was high in coiled aneurysms when compared with controls. There was no significant difference in the expression of Fas ligand among groups. Decreased expression of antiapoptotic proteins Bcl-2 and phospho-Bad, as well as increased expression of proapoptotic proteins Bax and Bid, was observed in coiled aneurysms at both time points. Conclusions— Activation of apoptosis in aneurysms after embolization with platinum coils is induced by both tumor necrosis factor-α–mediated extrinsic and Bcl-2-mediated intrinsic pathways.
A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms

Stroke | July 5, 2007 | Volume: 38 | Issue: 8 | Pages: 2346-2352

10.1161/strokeaha.106.479576 | PMID 17615366

Background and Purpose— We report a preclinical study of a new endoluminal device for aneurysm occlusion to test the hypothesis that the device, even without use of intrasaccular coil placement, could occlude saccular aneurysms without causing substantial parent artery compromise or compromise of adjacent, small branch arteries. Methods— The Pipeline Neuroendovascular Device (Pipeline NED; Chestnut Medical Technologies, Inc) is a braided, tubular, bimetallic endoluminal implant aimed at occlusion of saccular aneurysms through flow disruption along the aneurysm neck. The device was implanted across the necks of 17 elastase-induced aneurysms in the New Zealand white rabbit model and followed for 1 month (n=6), 3 months (n=5), and 6 months (n=6). In each subject, a second device was implanted in the abdominal aorta to cover the origins of lumbar arteries. Aneurysm occlusion rates by angiography (grade 1, complete occlusion; grade 2, near-complete occlusion; and grade 3, incomplete occlusion) were documented. Percent area stenosis of the parent arteries was calculated. Presence of distal emboli in the downstream vessels in the parent artery and branch artery stenosis or occlusion was noted. Results— Grades 1, 2, and 3 occlusion rates were noted in 9 (53%), 6 (35%), and 2 (12%) of 17 aneurysms, respectively, indicating an 88% rate of complete or near complete occlusion. No cases of branch artery occlusion or distal emboli in the downstream vessels of the parent artery, specifically the subclavian artery, were seen. Parent artery compromise from neointimal hyperplasia was minimal in most cases. Conclusions— The Pipeline NED is a trackable, bio- and hemocompatible device able to occlude saccular aneurysms with preservation of the parent artery and small, adjacent branch vessels.
Endovascular Treatment of Experimental Aneurysms by Use of Fibroblast-Coated Platinum Coils

Stroke | November 23, 2006 | Volume: 38 | Issue: 1 | Pages: 170-176

10.1161/01.str.0000252128.83405.71 | PMID 17122421

Background and Purpose— The purpose of this study was to determine whether implanting exogenous fibroblasts on platinum coils could enhance intra-aneurysmal fibrosis. Hypotheses included: (1) fibroblast-coated (FBC) platinum coils can improve angiographic results after embolization; and (2) FBC platinum coils can accelerate histological healing of embolized aneurysms. Methods— Experimental aneurysms in rabbits were embolized with control platinum coils (n=18) or FBC coils (n=18). Subjects were euthanized at 14 days, 1 month, 3 months and 6 months after implantation. Digital subtraction angiography was used to evaluate stability after embolization. Histological samples were examined with a grading system (range, 0 to 12) based on neck and dome healing. Results— Histology total scores and fibrosis ratio at 14 days were significantly greater in the FBC coil group compared with controls (6.6±1.9 versus 2.5±1.1, 1.2±0.6% versus 0.2±0.3%, respectively; P =0.0090). Cavities embolized with FBC coils showed cellular proliferation and thrombus organization, with an endothelialized membrane bridging the neck. There were no differences between groups in the later timepoints. The FBC coil group showed radiographic stability in 11 (61%) cases, coil compaction in 2 (11%) cases, and progressive occlusion in 5 (28%) cases. No progressive occlusion was seen in controls; 3 (17%) of 18 control cases exhibited coil compaction ( P =0.0546). Conclusions— FBC coils can accelerate early histological healing compared with control coils in the rabbit aneurysm model.