Coronary angiography is the gold standard for the diagnosis and treatment of epicardial coronary artery disease. Further, it is an essential tool for conduction of translational cardiac research on large animal models, in the development of novel cardiac therapies. While in humans coronary angiography has an exceedingly low mortality rate; in pigs, procedural mortality has been reported as high as 15%, likely due to unsuitable variations in angiographic techniques. Porcine models are used due to the resemblance of cardiac function and anatomy to humans. However, procedural guidelines delineating proper equipment to be used for angiography in this model has yet to be systematically assessed. Aims: To evaluate clinically common catheters for their utility in the safe engagement of the coronary vessels in pigs. Establish optimal workflow and fluoroscopy views for safe coronary artery engagement and angiography. Method/Results: Percutaneous superficial femoral artery access was acquired via ultrasound guidance and subsequent cardiac catheterization was performed in sus domesticus weighing 35-50 kg. Catheters that were tested included the JL 2.5, JL3.0, JR 3.0, AR1, AL1, MPA1, Champ1, 3DRC, hockey stick and RCB (5-7 french) operated over a standard .035 J tip wire. AP views were optimum to engage both the left and right coronary vessels. Only AR1, 3DRC, and hockey stick catheters successfully engaged the RCA, while all catheters tested could successfully engage the LCA. AR1 was noted to be the best for RCA engagement and AL1 for Left system engagement. AR1 was also the most succesful in engagement of both LM and RCA in same pig. AL1 provided the most stable engagement for Left coronary system. AR1/JL were better for LAD intervensions. AL1 is best for LCX intervensions Conclusion: We present a systematic description of percutaneous coronary angiographic procedures highlighting that AL for the LCA and AR for the RCA are the best choice of catheters for fastest and safest engagement of the coronary arteries limiting both radiation time and contrast use. While variations in anatomy can mandate changes in angiographic angles and catheter techniques, AP visualization and use of AL and AR catheters provided the most consistent and effective approach for porcine angiography.
Abstract 13454: Safe Large Bore Access via the Third Part of the Axillary Artery for Mechanical Circulatory Support Implantation
Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available
For patients in cardiogenic shock, percutaneous mechanical circulatory support devices (MCSD) have emerged as critical tool to improve hemodynamics and optimize end-organ perfusion; successfully bridging patients to recovery, decision or transplantation. The most commonly utilized MCSD is the femoral intra-aortic balloon pump (IABP). However, femoral access hampers the patient's mobility, quality of life, and capacity to participate in rehabilitation. The advent of the axillary artery approach has served to circumvent limitations associated with the femoral artery approach. However, optimum anatomical placement of IABP within the axillary artery (axIABP) is a topic of debate considering its proximity to the brachial plexus. Here, we report our experince with percutaneous access of the third poriton of the axillary artery which showed promising results with minimal device related complications or adverse events. Methods/Results: Between 2017-2023, a total of 89 patients in cardiogenic shock underwent percutaneous axIABP placement at the Mayo Clinic, MN. All demographic, clinical, and periprocedural data were obtained from hospital chart review and recorded in a database under IRB approval. Indications for axIABP support was determined by multidisciplinary assessment. Complications encountered in the cohort included infection at site 6.7% (n=6), device malfunction [rupture, fracture, leak] 8.98%(n=8), and balloon migration 5.61% (n=5). One patient developed local erythema, 4 (4.49%) patients developed significant vascular complications, including access site bleeding in two patients 2.24%, arterial thrombosis in three patients 3.37%, and self-limited intracranial bleeding in one patient 1.12%. Of note, no nerve injury or damage was observed in the entire patient cohort. Conclusion: Our study highlights the feasibility of percutaneous axIABP in the third portion of the axillary artery, while assessing safety profile and ease of removal. Notably in our review, we did not encounter any brachial nerve damage. Ultrasound was pivotal in identifying and avoiding nerves and nerve bundles during initial access. In conclusion, this approach of axIABP insertion is feasible and can be leveraged for delivery of future innovation in MCSD
A Comparative Study of Two Topical Treatments for Photoaging of the Hands
Plastic & Reconstructive Surgery | December 12, 2023 | Volume: 154 | Issue: 5 | Pages: 978-984
Background: Multiple effective treatments exist for correction of skin photoaging. Topical L-ascorbic acid (vitamin C), a well-known antioxidant and topical human platelet extract (HPE), is a novel off-the-shelf cosmetic ingredient that has shown positive results in recent clinical studies. HPE is a leukocyte-depleted allogeneic product derived from United States–sourced, pooled, apheresed platelets produced with consistent batch quality, purity, and effect. The authors sought to characterize the effect of topical HPE (plated) intense serum (Rion Aesthetics) compared with vitamin C (C E Ferulic with 15% L-ascorbic acid; SkinCeuticals) in skin rejuvenation of dorsal hands after 12 to 26 weeks of twice-daily use. Methods: This prospective, longitudinal study sought to compare the effectiveness of 2 known treatments for skin rejuvenation. Evaluations at baseline and 6, 12, and 26 weeks included photographic documentation to assess common skin concerns related to aging. Results: For age-related skin appearance on the dorsal hands, topical HPE was noninferior to topical vitamin C for improvement in brown spot fractional area, wrinkle fractional area, and improvement in luminosity at 12 weeks after twice-daily topical use. Conclusions: HPE performed as well as vitamin C to rejuvenate the skin on the dorsal hands after 12 to 26 weeks of twice-daily topical use. Both topical serums may yield similar or superior results versus invasive procedures, such as intense pulsed light, in reducing brown spots on the dorsal hands. These topical products work equally well in both sexes. Skin improvements lasted through 6 months. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.
Reconstituted Extracellular Vesicles from Human Platelets Decrease Viral Myocarditis in Mice (Small 49/2023)
Small | December 8, 2023 | Volume: 19 | Issue: 49 | Pages: No page available
Abstract Patients with heart failure experience limitations in daily activity and poor quality-of-life. Prospective surveillance of health-related quality-of-life supplemented traditional death and hospitalization outcomes in the multinational, randomized, double-blinded CHART-1 clinical trial that assessed cardiopoiesis-guided cell therapy in ischemic heart failure patients with reduced left ventricular ejection fraction. The Minnesota Living with Heart Failure Questionnaire (MLHFQ), a Food and Drug Administration qualified instrument for evaluating therapeutic effectiveness, was applied through the 1-year follow-up. Cell treated (n = 109) and sham procedure (n = 140) cohorts reported improved MLHFQ scores comparable between the 2 study arms (mean treatment difference with baseline adjustment −3.2 points, P = .107). Superiority of cell treatment over sham in betterment of the MLHFQ score was demonstrated in patients with pre-existing advanced left ventricular enlargement (baseline-adjusted mean treatment difference −6.4 points, P = .009). In this highly responsive subpopulation, benefit on the MLHFQ score paralleled reduction in death and hospitalization post-cell therapy (adjusted Mann-Whitney odds 1.43, 95% CI, 1.01-2.01; P = .039). The potential of cell therapy in addressing the quality-of-life dimension of heart failure requires further evaluation for disease relief.
Reconstituted Extracellular Vesicles from Human Platelets Decrease Viral Myocarditis in Mice
Small | August 24, 2023 | Volume: 19 | Issue: 49 | Pages: No page available
AbstractPatients with viral myocarditis are at risk of sudden death and may progress to dilated cardiomyopathy (DCM). Currently, no disease‐specific therapies exist to treat viral myocarditis. Here it is examined whether reconstituted, lyophilized extracellular vesicles (EVs) from platelets from healthy men and women reduce acute or chronic myocarditis in male mice. Human‐platelet‐derived EVs (PEV) do not cause toxicity, damage, or inflammation in naïve mice. PEV administered during the innate immune response significantly reduces myocarditis with fewer epidermal growth factor (EGF)‐like module‐containing mucin‐like hormone receptor‐like 1 (F4/80) macrophages, T cells (cluster of differentiation molecules 4 and 8, CD4 and CD8), and mast cells, and improved cardiac function. Innate immune mediators known to increase myocarditis are decreased by innate PEV treatment including Toll‐like receptor (TLR)4 and complement. PEV also significantly reduces perivascular fibrosis and remodeling including interleukin 1 beta (IL‐1β), transforming growth factor‐beta 1, matrix metalloproteinase, collagen genes, and mast cell degranulation. PEV given at days 7–9 after infection reduces myocarditis and improves cardiac function. MicroRNA (miR) sequencing reveals that PEV contains miRs that decrease viral replication, TLR4 signaling, and T‐cell activation. These data show that EVs from the platelets of healthy individuals can significantly reduce myocarditis and improve cardiac function.
A Ready-to-Use Purified Exosome Product for Volumetric Muscle Loss and Functional Recovery
Tissue Engineering Part A | August 4, 2023 | Volume: 29 | Issue: 17-18 | Pages: 481-490
Safety and efficacy of human platelet extract in skin recovery after fractional CO2 laser resurfacing of the face: A randomized, controlled, evaluator‐blinded pilot study
Journal of Cosmetic Dermatology | July 7, 2023 | Volume: 22 | Issue: 9 | Pages: 2464-2470
AbstractBackgroundFractional carbon dioxide (CO2) laser resurfacing is used successfully for facial rejuvenation. Post procedure skincare is a variable that influences downtime caused by pain/tenderness, erythema, crusting, and bruising.AimsThe primary objective of this pilot study was to demonstrate the benefits of human platelet extract (HPE) (plated)™ CALM Serum, a new topical cosmetic product, following fractionated CO2 ablative laser resurfacing treatment to the entire face versus standard of care.MethodsIn a single‐center, randomized, evaluator‐blinded pilot study, a total of 18 subjects were randomized into two groups, CO2 facial resurfacing followed by post‐procedural standard of care (Stratacel silicone gel) or CO2 facial resurfacing with the addition of HPE renewosomes in the CALM Serum.ResultsCALM Serum demonstrated statistically significant less crusting at Day 10 compared to the control group (p = 0.0193) with less downtime in the first 14 days (p = 0.03). Subjects treated with CALM Serum had statistically significant brighter appearing skin at 14 days (p = 0.007) and more youthful looking skin on Days 14 and 30 (p = 0.003 and 0.04, respectively).ConclusionsThis study demonstrates that Renewosome™ technology provides statistically significant post‐laser clinical recovery over silicone gel for reducing crusting, and downtime. Subjects reported less diary days of symptoms of pain/tenderness, redness, crusting/flaking, bruising, and itching in the first 14 days compared to the control group. CALM also demonstrated statistically significant improvements in brighter and more youthful appearing skin. CALM is safe and well tolerated.
Nebulized Platelet-derived Extracellular Vesicles Attenuate Cigarette Smoke-induced Inflammation in a Murine Model
C69. PRECLINICAL COPD MODELS: IN VITRO, EX VIVO, IN VIVO | May 1, 2023 | Volume: No volume available | Issue: No issue available | Pages: A5702-A5702
Background: Nerve injuries can result in detrimental functional outcomes. Currently, autologous nerve graft offers the best outcome for segmental peripheral nerve injury. Allografts are alternatives, but do not have comparable results. This study evaluated whether plasma-derived exosome can improve nerve regeneration and functional recovery when combined with decellularized nerve allografts. Methods: The effect of exosomes on Schwann cell proliferation and migration were evaluated. A rat model of sciatic nerve repair was used to evaluate the effect on nerve regeneration and functional recovery. A fibrin sealant was used as the scaffold for exosome. Eighty-four Lewis rats were divided into autograft, allograft, and allograft with exosome groups. Gene expression of nerve regeneration factors was analyzed on postoperative day 7. At 12 and 16 weeks, rats were subjected to maximum isometric tetanic force and compound muscle action potential. Nerve specimens were then analyzed by means of histology and immunohistochemistry. Results: Exosomes were readily taken up by Schwann cells that resulted in improved Schwann cell viability and migration. The treated allograft group had functional recovery (compound muscle action potential, isometric tetanic force) comparable to that of the autograft group. Similar results were observed in gene expression analysis of nerve regenerating factors. Histologic analysis showed no statistically significant differences between treated allograft and autograft groups in terms of axonal density, fascicular area, and myelin sheath thickness. Conclusions: Plasma-derived exosome treatment of decellularized nerve allograft may provide comparable clinical outcomes to that of an autograft. This can be a promising strategy in the future as an alternative for segmental peripheral nerve repair. Clinical Relevance Statement: Off-the-shelf exosomes may improve recovery in nerve allografts.