Citations 157

Renal stone characterization using high resolution imaging mode on a photon counting detector CT system

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323J

10.1117/12.2255651 | PMID 28458443

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101321R

10.1117/12.2255593 | PMID 28392614

Practical implementation of channelized hotelling observers: effect of ROI size

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320G

10.1117/12.2255530 | PMID 28943699

Dual energy CT kidney stone differentiation in photon counting computed tomography

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 1013237

10.1117/12.2252021 | PMID 28943700

A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.
Implementation and evaluation of a protocol management system for automated review of CT protocols

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 17 | Issue: 5 | Pages: 523-533

10.1120/jacmp.v17i5.6164 | PMID 27685112

Protocol review is important to decrease the risk of patient injury and increase the consistency of CT image quality. A large volume of CT protocols makes manual review labor‐intensive, error‐prone, and costly. To address these challenges, we have developed a software system for automatically managing and monitoring CT protocols on a frequent basis. This article describes our experiences in the implementation and evaluation of this protocol monitoring system. In particular, we discuss various strategies for addressing each of the steps in our protocol‐monitoring workflow, which are: maintaining an accurate set of master protocols, retrieving protocols from the scanners, comparing scanner protocols to master protocols, reviewing flagged differences between the scanner and master protocols, and updating the scanner and/or master protocols. In our initial evaluation focusing only on abdomen and pelvis protocols, we detected 309 modified protocols in a 24‐week trial period. About one‐quarter of these modified protocols were determined to contain inappropriate (i.e., erroneous) protocol parameter modifications that needed to be corrected on the scanner. The most frequently affected parameter was the series description, which was inappropriately modified 47 times. Two inappropriate modifications were made to the tube current, which is particularly important to flag as this parameter impacts both radiation dose and image quality. The CT protocol changes detected in this work provide strong motivation for the use of an automated CT protocol quality control system to ensure protocol accuracy and consistency.PACS number(s): 87.57.Q‐
An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features

Medical Physics | February 25, 2017 | Volume: 44 | Issue: 5 | Pages: 1610-1623

10.1002/mp.12174 | PMID 28236645

PurposeTo develop and evaluate an image‐domain noise reduction method for multi‐energy CT (MECT) data.MethodsMulti‐Energy Non‐Local Means (MENLM) is a technique that uses the redundant information in MECT images to achieve noise reduction. In this method, spatio‐spectral features are used to determine the similarity between pixels, making the similarity evaluation more robust to image noise. The performance of this MENLM filter was tested on images acquired on a whole‐body research photon counting CT system. The impact of filtering on image quality was quantitatively evaluated in phantom studies in terms of image noise level (standard deviation of pixel values), noise power spectrum (NPS), in‐plane and cross‐plane spatial resolution, CT number accuracy, material decomposition performance, and subjective low‐contrast spatial resolution using the American College of Radiology (ACR) CT accreditation phantom. Clinical feasibility was assessed by performing MENLM on contrast‐enhanced swine images and unenhanced cadaver head images using clinically relevant doses and dose rates.ResultsThe phantom studies demonstrated that the MENLM filter reduced noise substantially and still preserved the shape and peak frequency of the NPS. With 80% noise reduction, MENLM filtering caused no degradation of high‐contrast spatial resolution, as illustrated by the modulation transfer function (MTF) and slice sensitivity profile (SSP). CT number accuracy was also maintained for all energy channels, demonstrating that energy resolution was not affected by filtering. Material decomposition performance was improved with MENLM filtering. The subjective evaluation using the ACR phantom demonstrated an improvement in low‐contrast performance. MENLM achieved effective noise reduction in both contrast‐enhanced swine images and unenhanced cadaver head images, resulting in improved detection of subtle vascular structures and the differentiation of white/gray matter.ConclusionIn MECT, MENLM achieved around 80% noise reduction and greatly improved material decomposition performance and the detection of subtle anatomical/low‐contrast features while maintaining spatial and energy resolution. MENLM filtering may improve diagnostic or functional analysis accuracy and facilitate radiation dose and contrast media reduction for MECT.
Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 | PMID 28042589

Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner

Journal of Medical Imaging | December 14, 2016 | Volume: 3 | Issue: 4 | Pages: 043503

10.1117/1.jmi.3.4.043503 | PMID 28018936