Citations 183

Incidence, risk factors, natural history and outcomes of heart failure in patients with Graves’ disease

Heart | September 6, 2021 | Volume: 108 | Issue: 11 | Pages: 868-874

10.1136/heartjnl-2021-319752 | PMID 34489313

Objective Graves’ disease (GD) can both aggravate pre-existing cardiac disease and cause de novo heart failure (HF), but large-scale studies are lacking. We aimed to investigate the incidence, risk factors and outcomes of incident GD-related HF. Methods Patients with GD (2009–2019) were retrospectively included. HF with reduced ejection fraction (HFrEF) was defined by left ventricular ejection fraction <50% and Framingham criteria, while HF with preserved ejection fraction (HFpEF) was defined according to the HFA-PEFF criteria. HF due to ischaemia, valve disorder or other structural heart disease was excluded. Proportional hazards regression was used to analyse risk factors and outcomes. Results Of 1371 patients with GD, HF occurred in 74 (5.4%) patients (31 (2.3%) HFrEF; 43 (3.1%) HFpEF). In HFrEF, atrial fibrillation (AF) (HR 10.5 (3.0–37.3), p<0.001) and thyrotropin receptor antibody (TRAb) level (HR 1.05 (1.01–1.09) per unit, p=0.007) were independent risk factors. In HFpEF, the independent risk factors were chronic obstructive pulmonary disease (HR 7.2 (3.5–14.6), p<0.001), older age (HR 1.5 (1.2–2.0) per 10 years, p=0.001), overt hyperthyroidism (HR 6.4 (1.5–27.1), p=0.01), higher body mass index (BMI) (HR 1.07 (1.03–1.10) per unit, p=0.001) and hypertension (HR 3.1 (1.3–7.2), p=0.008). The risk of cardiovascular hospitalisations was higher in both HFrEF (HR 10.3 (5.5–19.4), p<0.001) and HFpEF (HR 6.7 (3.7–12.2), p<0.001). However, only HFrEF was associated with an increased risk of all-cause mortality (HR 5.17 (1.3–19.9), p=0.02) and ventricular tachycardia/fibrillation (HR 64.3 (15.9–259.7), p<0.001). Conclusion De novo HF occurs in 5.4% of patients with GD and is associated with increased risk of cardiovascular hospitalisations and mortality. Risk factors include AF, higher TRAb, higher BMI and overt hyperthyroidism.
High Prevalence of Severe Aortic Stenosis in Low-Flow State Associated With Atrial Fibrillation

Circulation: Cardiovascular Imaging | July 12, 2021 | Volume: 14 | Issue: 7 | Pages: No page available

10.1161/circimaging.120.012453 | PMID 34250815

Background: Atrial fibrillation (AF) is a low-flow state and may underestimate aortic stenosis (AS) severity. Single-high Doppler signals (HS) consistent with severe AS (peak velocity ≥4 m/s or mean gradient ≥40 mm Hg) are averaged down in current practice. The objective for the study was to determine the significance of HS in AF low-gradient AS (LGAS). Methods: One thousand five hundred forty-one patients with aortic valve area ≤1 cm 2 and left ventricular ejection fraction ≥50% were identified and classified as high-gradient AS (HGAS) (≥40 mm Hg) and LGAS (<40 mm Hg), and AF versus sinus rhythm (SR). Available computed tomography aortic valve calcium scores (AVCS) were retrieved from the medical record. Outcomes were assessed. Results: Mean age was 76±11 years, female 47%. Mean gradient was 51±12 in SR-HGAS, 48±10 in AF-HGAS, 31±5 in SR-LGAS, and 29±7 mm Hg in AF-LGAS, all P ≤0.001 versus SR-HGAS; HS were present in 33% of AF-LGAS. AVCS were available in 34%. Compared with SR-HGAS (2409 arbitrary units; interquartile range, 1581–3462) AVCS were higher in AF-HGAS (2991 arbitrary units; IQR1978–4229, P =0.001), not different in AF-LGAS (2399 arbitrary units; IQR1817–2810, P =0.47), and lower in SR-LGAS (1593 arbitrary units; IQR945–1832, P <0.001); AVCS in AF-LGAS were higher when HS were present ( P =0.048). Compared with SR-HGAS, the age-, sex-, comorbidity index-, and time-dependent aortic valve replacement-adjusted mortality risk was higher in AF-HGAS (hazard ratio=1.82 [1.40–2.36], P <0.001) and AF-LGAS with HS (hazard ratio=1.54 [1.04–2.26], P =0.03) but not different in AF-LGAS without HS or SR-LGAS (both P =not significant). Conclusions: Severe AS was common in AF-LGAS. AVCS in AF-LGAS were not different from SR-HGAS. AVCS were higher and mortality worse in AF-LGAS when HS were present.
Clinical predictors and impact of postoperative mean gradient on outcome after transcatheter edge‐to‐edge mitral valve repair

Catheterization and Cardiovascular Interventions | July 10, 2021 | Volume: 98 | Issue: 6 | Pages: No page available

10.1002/ccd.29867 | PMID 34245208

AbstractBackgroundThe predictors and clinical significance of increased Doppler‐derived mean diastolic gradient (MG) following transcatheter edge‐to‐edge mitral valve repair (MVTEER) remain controversial.ObjectiveWe sought to examine baseline correlates of Doppler‐derived increased MG post‐MVTEER and its impact on intermediate‐term outcomes.MethodsPatients undergoing MVTEER were analyzed retrospectively. Post‐MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D‐guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients.Results243 patients were included; 62 (26%) had MG > 5 mmHg post‐MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post‐MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post‐MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15–3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06–13.28 p < 0.001).ConclusionsSmaller baseline MVA and increased baseline MG are associated with increased MG post‐MVTEER and patients with a Doppler‐derived post‐MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.
Abstract 18192: Aortic Stenosis: The Effect of Spectral Broadening in the Left Ventricular Outflow Tract on Stroke Volume and Calculated Aortic Valve Area

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.18192

Introduction: Accurate stroke volume (SV) calculation is critical for calculating aortic valve area by echocardiography. 2D-Doppler estimation of SV (SV 2D ) assumes uniform blood flow velocities through the left ventricular outflow tract (LVOT). Non-uniform flow through the LVOT, appreciated as spectral broadening of the LVOT Doppler signal, could result in inaccurate SV calculation. Hypothesis: Increased spectral broadening in the LVOT will result in overestimation of SV by the SV 2D method compared to 3D volumetric assessment of SV (SV 3D ). Methods: Fifty-one consecutive patients with aortic stenosis underwent comprehensive 2D-TTE and assessment of SV 3D . Patients with ≥ moderate mitral or aortic regurgitation were excluded. An LVOT pulse-wave Doppler signal with > 0.4 m/s difference between outer and inner edge of velocity spectral display (at time of peak velocity) was considered non-uniform flow (i.e., spectral broadening). Results: Spectral broadening was present in 33% of the cohort. These patients were commonly female with smaller ventricles and higher ejection fraction. Spectral broadening was associated with a significant overestimation of SV on Doppler-based measurements (101±20 ml vs 78±15 mL, SV 2D vs SV 3D , respectively; r=0.83, p<0.0001); such differences were not seen in patients with uniform flow velocities (82±15 vs 79±14 mL, r=0.83, p=0.03). Patient characteristics by spectral broadening are shown in table 1. Conclusion: In aortic stenosis patients with non-uniform flow, Doppler-based methods overestimated SV by 29.5% on average (maximum 64%) when compared to 3D methods. This results in a proportional increase in calculated valve area despite a similar mean gradient between groups. Substituting SV 3D resulted in similar SV, valve area, and mean gradient between uniform and non-uniform groups. When spectral broadening >0.40 cm/s is present, 3D volumetric assessment of SV should be considered for accurate estimation of aortic valve area.
Abstract 17686: Appropriate Use and Clinical Impact of Early Echocardiograms in Hospitalized Patients

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.17686

Introduction: Transthoracic echocardiography (TTE) is a versatile tool for investigating cardiac function in hospitalized patients, but it was recently suggested that only a fraction of the studies result in an active change in management. The importance of early inpatient TTE to guide management and rule out important alternative pathology has not been previously investigated. The opinion of the referring provider has never been systematically surveyed. Hypothesis: Appropriate use (AU) of TTE in hospitalized patients has significant implications for patient care, even without resulting in direct alterations in management. Methods: We conducted a prospective review of 546 consecutive echocardiograms performed within 72 hours of hospital admission. An electronic survey consisting of 6 questions pertinent to rationale for TTE and consequences to patient care was sent to physicians. AU was independently determined by two investigators blinded to survey results and clinical outcomes, with differences adjudicated by a third independent investigator. Results: Of 546 TTEs included in this study, 526 (96%) were appropriate, 2% inappropriate, and 2% uncertain. Although only 48% of responders actively changed management after TTE results, 97% thought the TTE answered their clinical question. At least one new medication change occurred in 190 (35%) patients. Moreover, 95% of physicians would do another TTE in a similar situation, either to guide cardiac therapy, rule out contributing cardiac pathology, or support their current therapeutic plan. Only 5% of responders would not order another TTE if given a similar presentation in the future. Furthermore, our study uncovered a high incidence of unexpected findings (33% of TTEs), ranging from new decrease in LV systolic function, new valvular dysfunction, to pericardial effusion and new aortic aneurysm. These findings have significant clinical implications for the individual patient. Conclusions: Most early inpatient TTEs at our institution were appropriate and answered a specific clinical question important for management decisions. Even those not directly altering the acute therapeutic strategy impacted clinical course. A large number of significant incidental findings were recorded.
Abstract 16898: Time Course and Associated Cardiac Conditions of Reduced Left Ventricular Ejection Fraction in Patients With Severe Aortic Stenosis

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16898

Objective: In patients with aortic stenosis (AS), the development of left ventricular (LV) systolic dysfunction adversely affects the natural history and is associated with poor outcomes following aortic valve replacement. However, the timing and possible reasons for transition from preserved to impaired LV ejection fraction (LVEF) in patients with AS have not been described. The aim of this study was to describe the time course of development of LV dysfunction and associated conditions in patients with severe AS. Methods & Results: Between 1/1/2009 and 12/31/2012, 667 (19%) of 3528 patients with severe AS (aortic valve area (AVA) ≤1 cm2) identified from the Mayo Clinic, Rochester, MN Echocardiographic Laboratory database; had LVEF ≤50%. Of those 667 patients, 263 (39%) had previous echocardiograms (median: 71.6 months, 25 IQR: 36.3, 75:118.2) before the development of severe AS, allowing an assessment of change in LVEF over time. Among these 263 patients, 8 (3%) had dilated cardiomyopathy (DCM), 225 (86%) had ischemic heart disease (IHD), 5 (2%) had other significant valve disease, and 25 (10%) had no concomitant heart disease before the development of severe AS. The evolution of development of reduced LVEF at several time points is shown in the Figure. The initial LVEF was 34±12 % in DCM patients, 51±13% in IHD patients and 61±9 % in AS patients without other heart diseases (p<0.001, ANOVA). Patients with AS alone or AS+DCM/IHD showed a gradual decline in LVEF before AS became severe, and a more rapid decline in LVEF once the AVA reached ≤ 1 cm2. Conclusion: In patients with severe AS, a majority of the patients (86%) with reduced EF had ischemic heart disease. Although there was a gradual decline in LVEF before development of severe AS, the decline was more rapid after AS became severe in almost all patients regardless of associated cardiac condition. More frequent monitoring may be indicated in AS patients especially when AVA reaches 1cm2 and concomitant IHD.
Abstract 14140: The Weight of the Evidence: Comparison of Operatively Excised Aortic Valve Weights in Patients With High Gradient versus Low Gradient Aortic Stenosis and Overall Survival Following Aortic Valve Replacement

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14140

Introduction: Excised aortic valve weight (AVW) correlates with severity of AS. There is some debate about the true severity of AS in low gradient AS (LGAS) compared to high gradient AS (HGAS). We sought to compare patient characteristics and operatively excised AVW in patients with LGAS vs HGAS vs moderate AS. Methods: 916 patients with EF ≥50% undergoing surgical aortic valve replacement for AS between 2010-2012 were included. Clinical and echocardiographic characteristics of LGAS patients (AVA≤1cm 2 , MnG<40mmHg; N=68) were compared to HGAS patients (AVA≤1cm 2 , MnG≥40mmHg; N=745) and operatively excised AVW were compared to moderate AS (AVA>1cm 2 , MnG<40mmHg; N=102). Results: Compared to HGAS, LGAS patients were older (mean age 77 ± 10 vs 73 ± 10 years; p=0.001), often female (56% vs 38%; p=0.006), but without differences in diabetes (26% vs 29%; p=0.78), hyperlipidemia (85% vs 86%, p=0.86), coronary artery disease (49% vs 44%; p=0.53), or hypertension (81% vs 76%; p=0.38). LGAS patients predominantly had trileaflet aortic valves (91% vs 71%; p<0.001), smaller LVOT diameter (2.16 ± 0.15 vs 2.25 ± 0.20 cm; p=0.002), lower stroke volume index (42.1 ± 7.3 vs 49.0 ± 8.8 cc/m 2 ; p<0.001), lower systemic compliance (0.77 ± 0.30 vs 0.93 ± 0.33 ; p<0.001), but no difference in valvulo-arterial impedance (3.96 ± 0.76 vs. 3.84 ± 0.80, p=0.24) compared to HGAS. Excised AVW were lower in patients with LGAS vs HGAS (1.77 ± 0.76 vs 2.69 ± 1.26 g, p<0.001), but not different from moderate AS (1.77 ± 0.76 vs 2.04 ± 0.94 g; p=0.1). This relationship held true when AVW was indexed to body surface area. Three-year mortality post-valve replacement was significantly higher in LGAS compared to HGAS (22% vs 11%, p=0.02). Conclusions: LGAS occurs mostly in older female patients with trileaflet aortic valves. Excised AVW in LGAS is similar to moderate AS but lower than HGAS. However, systemic compliance is higher in LGAS vs HGAS contributing to increased afterload. Poorer outcomes after surgery in LGAS patients may be attributed to noncompliant vasculature which is not corrected with valve replacement and evaluation of patients with LGAS should include assessment of peripheral resistance.
Abstract 10261: Musculoskeletal Pain in Cardiac Sonographers: A Multisite Case Control Study

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.10261

Background: Transthoracic echocardiography is the mainstay of cardiac imaging and is highly dependent upon cardiac sonographers for whom image acquisition can be physically demanding and associated with musculoskeletal pain. Prior studies are limited by the absence of adequate control groups and a lack of adjustment for potential confounders. Objectives: The purpose of this study was to determine the prevalence and impact of work-related musculoskeletal pain in cardiac sonographers as compared to a large control group of non-invasive healthcare professionals with similar demographics. Methods: An electronic survey was administered to Mayo Clinic employees identified by human resources at six major patient care facilities in four different states. Results: There were 2682 employees within the departments of cardiology and radiology who were contacted and 1532 (57%) completed the survey. After exclusion of those who wear protective lead aprons, 517 employees comprised the control group and 66 cardiac sonographers made up the study group. Cardiac sonographers and the control group were similar in age, sex, BMI, length of employment and history of prior musculoskeletal pain. Cardiac sonographers reported work-related musculoskeletal pain more frequently than the control group (88% vs 40%; p<0.001). This association persisted after multivariable adjustment for age, sex, body mass index, length of current employment and history of pre-existing musculoskeletal pain (OR 11.6; (95% CI 5.32, 25.5); p<0.001). Cardiac sonographers were more likely to seek medical care for their work-related pain (55% vs 21%; p<0.001) and to have missed work due to pain (35% vs 12%, p<0.001). Conclusions: In this multi-site case control study, cardiac sonographers experienced significantly more work-related pain and missed more work due to pain than a large control group of non-invasive healthcare professionals with similar demographics.
Abstract 15742: Predicting Outcomes After Percutaneous Mitral Balloon Valvotomy: The Impact of Left Ventricular Strain Imaging

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.15742

Introduction: Presence of subclinical left ventricle (LV) dysfunction may influence outcomes after percutaneous mitral balloon valvotomy (PMBV), but cannot be detected by conventional echocardiography. Hypothesis: Preprocedure LV global longitudinal strain (GLS) by speckle tracking TTE detects subclinical LV dysfunction and predicts long-term outcome after successful PMVB. Methods: Consecutive patients undergoing PMBV between 2003-2011 who had comprehensive baseline TTE were included. Patients with suboptimal immediate results (repeat PMBV or mitral surgery within first 6 months) and those with suboptimal TTE strain were excluded. LV strain was analyzed with commercial software (Syngo VVI), and GLS averaged from 18 segments. The primary end point was all-cause mortality. Secondary end point was the composite of death and mitral valve reintervention. Results: Of 110 patients screened, 29 (26%) had unsuitable strain imaging, and 8 (7%) had poor immediate results, leaving 73 in the final cohort. Median follow-up was 3.7 years (interquartile range 1.3-7.2). There were 10 deaths (14%) and 25 late mitral valve interventions (34%). Univariate predictors of death were GLS, age, EF, stroke volume, pulmonary artery pressure, mitral valve area and coronary artery disease. In a multivariate Cox model, GLS was the strongest predictor of death after adjustment for age [HR=1.40 (1.09-1.84), P=0.008]. For the composite endpoint, GLS, mitral valve gradient, and invasively mean left atrial pressure were univariate predictors of death or reintervention. At multivariate analysis, GLS was the sole predictor of events [HR=1.17 (1.01-1.34), P=0.03]. Event-free survival is shown in figure. Intra and inter observer intra-class correlation for strain analysis was 0.87 (0.66-0.96) and 0.84 (0.53-0.95), respectively. Conclusions: GLS is a powerful predictor of long-term outcome after PMVB and appears to have an incremental prognostic value over traditional parameters.
Abstract 15719: Right Ventricular Dysfunction After Transcatheter Aortic Valve Replacement (TAVR)

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.15719

Background: Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement in patients at high surgical risk. We investigated the impact of TAVR on left (LV) and right ventricular (RV) function using conventional echocardiography parameters. Methods and results: A total of 202 consecutive patients (age 80.6±8.0 years, aortic valve area 0.80±0.16cm 2 ) who underwent TAVR at Mayo Clinic between 2008 and 2013 were included in the study. LV ejection fraction (EF) and RV systolic function including tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC) and, systolic excursion velocity (S’) were compared before (median 33.5 days) and after TAVR procedure (median 30 days). Patients who underwent pacemaker implantation after TAVR were excluded. LV EF significantly improved following TAVR (55.3±12.6% pre vs 58.5±11.1% post; p<0.05). In contrast, RV systolic function significantly decreased after TAVR (pre vs post; TAPSE: 18.8±6.3 mm vs 17.4±6.3 mm, FAC: 42.6±9.8% vs 37.3±8.2%; S’: 10.7±2.6 cm/s vs 10.2±2.6 cm/s; p<0.05 for all). Stratifying RV functional change by TAVR approach site, patients undergoing trans-femoral TAVR (n=100) showed RV deterioration only by FAC (see Table). In contrast, RV systolic dysfunction was more prominent in trans-apical approach group (n=87) with significant decline in all parameters of RV systolic function (see Table). Conclusion: TAVR is associated with early enhancement in LV systolic function. However, there is evidence of worsening RV function in a significant number of patients. Further studies are necessary to determine whether this deterioration in RV function is related to anatomic access site or to other factors, and to evaluate its prognostic significance.