Citations 158

A-144 Liquid chromatography multiple reaction monitoring-based assay for quantitative assessment of fibrinogen levels in clinical samples

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.142

Abstract Background Fibrinogen plays a critical role in hemostasis and is essential to clot formation. Changes in the quantity or activity of fibrinogen can lead to disorders affecting coagulation. Thus, it is essential to precisely quantify fibrinogen levels to differentiate between hyperfibrinogenemia in hypercoagulable disorders and dysfibrinogenemia, hypo/afibrinogenemia, and irregular bleeding. Current diagnostic tests that use antibodies to detect fibrinogen or activity-based measures are susceptible to interference from heparin contamination, hemolysis, and hyperbilirubinemia. Here, we evaluated the use of targeted proteomics for developing a quantitative assay for fibrinogen in plasma samples. Methods Four peptides each for alpha and gamma chains of fibrinogen were synthesized using FMOC chemistry on a Liberty Blue (CEM Corp) peptide synthesizer. A targeted multiple reaction monitoring (MRM) assay was developed and optimized using Dionex Ultimate 3000 HPLC connected to a TSQ Altis triple quadrupole mass spectrometer (Thermo Scientific). Evaluations were conducted using a range of standards, such as pure protein, WHO plasma and commercially available plasma with known fibrinogen amounts for the accurate quantitation of fibrinogen. Calibration curves were generated using different dilutions in various matrices. The repeatability and precision of the assay were evaluated across five different days. The plasma samples were processed and digested in a 96-well plate and subjected to C18 clean-up using a Bravo automated liquid handler (Agilent). All samples were spiked-in with corresponding heavy-labeled peptides prior to digestion with trypsin. Multiple reaction monitoring assays were performed on tryptic digests of plasma samples. Results Calibration curves using commercial plasma for all peptides showed linearity from 20 mg/dl to 1,308 mg/dl. This covers the entire clinical range including normal (200-350 mg/dl), deficient states (<100 mg/dl) and excess production (>350 mg/dl) that can be used for evaluation of bleeding disorders including consumption coagulopathy and hyperfibrinogenemia. Based on the overall performance in terms of linearity, limit of detection/quantitation, carryover and coefficient of variation (CV) across five different days, two peptides per chain were finally selected for developing the quantitative assay. The intra-assay variability was <5% and intra-day CV was ∼20%. This assay is currently being tested on a variety of clinical samples representing a range of fibrinogen levels. Conclusions Our study focused on assessing whether multiplexed MRM assay could be implemented to measure fibrinogen levels in plasma. Our data indicate the feasibility of MRM-based assays for determining fibrinogen levels as an alternative to existing non-mass spectrometry-based activity or antigen assays.
A-161 Diagnosis of Lupus Anticoagulant Cases using Deep Neural Networks

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.159

Abstract Background Laboratory identification of lupus anticoagulant (LAC) is critical for diagnosing antiphospholipid antibody syndrome, a common cause of unprovoked thromboembolic events and pregnancy morbidity. Commonly used clot-based assays for LAC include the dilute Russell’s viper venom time (DRVVT) and activated partial thromboplastin time (APTT), but these are susceptible to anticoagulant interferences. Despite standardization efforts, LAC interpretation remains challenging due to pre- and post-analytical complexity and limited expertise. This study explored the use of deep neural networks (DNN) to facilitate LAC diagnosis. Methods Retrospective data for LAC profiling with 13 features performed at Mayo Clinic between 2021 and 2022 was collected. The profiles of 7,202 patients were randomly divided into training (n=4608), validation (n=1153), and test cohorts (n=1441). Diagnostic outputs including LAC positivity (determined by DRVVT or APTT) and the presence of warfarin (WAR) and heparin (HEP), were confirmed by expert assessment. Three DNN architectures were developed and evaluated (Figure 1): (1) four single output DNN models with a domain knowledge driven selection of input features, (2) four single output DNN models using the same 13 inputs across all models, and (3) a multi-output DNN model. Model performance was evaluated using the F1 score and the index of balanced accuracy (IBA) for each output label. Results Architecture 1 achieved high diagnostic accuracy with IBA values of 0.989-1.000 for all four outputs and F1 scores of 0.945-0.991. Architecture 2 exhibited F1 scores of 0.902-0.973 and IBA values of 0.935-0.992. Architecture 3 achieved F1 scores of 0.933-0.967 and IBA values of 0.941-0.983. Conclusions All three architectures accurately classify LAC and common anticoagulation effects. The comparable performance of architectures 1 and 2 suggests that manual feature extraction is unnecessary. Given its relative simplicity and versatility, architecture 3 is the preferred choice for implementation in a clinical laboratory to standardize LAC diagnosis.
Neurosurgical bleeding in platelet storage pool disorder: a case report

Platelets | July 23, 2024 | Volume: 35 | Issue: 1 | Pages: No page available

10.1080/09537104.2024.2380374 | PMID 39041657

Null‐type SH2B3 mutations are potential drivers in a subset of Ph‐negative myeloproliferative neoplasms

American Journal of Hematology | June 25, 2024 | Volume: 99 | Issue: 9 | Pages: 1841-1844

10.1002/ajh.27411 | PMID 38924136

Abstract 9379: Biomarkers of Aortic Stenosis Severity

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a9379

Aortic stenosis (AS) requires repeat assessments to optimally time intervention. The utility of laboratory tests to complement clinical and hemodynamic assessments has not been established. We assessed clinical, echocardiographic, and laboratory data in 76 patients with AS or heart valve replacement (HVR), age 77 years, 37% women. Laboratory assessments included von Willebrand factor (VWF) antigen, activity, (Act/Ag, normal > 0.8), VWF multimer distribution (abnormal=loss of highest molecular weight multimers=Mult+), brain natriuretic peptide (BNP, abnormal > 155 pg/ml=BNP+), and platelet function analyzer 100 collagen-ADP closure time (PFA, normal < 121 seconds). Table: Coefficients of correlation, r, and F statistic. Chi-square, and probability. Correlation of BNP to mean gradient in patients with GFR>60 remained poor, r=0.29, while for PFA r = 0.65. Median (IQR) for PFA and BNP for mild, moderate, and severe AS and HVR are shown below. VWF multimers were abnormal in 3/14 mild AS, 6/14 moderate AS, 22/25 severe AS and 4/23 HVR patients. The severity of AS was most strongly associated with VWF multimer abnormality and prolonged PFA closure time, weakly with BNP, and not with VWF Act/Ag. Conclusion: Among various laboratory measures, PFA and VWF multimers are strongly associated with AS severity, and may merit assessment as complementary diagnostic and prognostic biomarkers in AS.
Type II mast cells in mast cell leukemia: Uncommon yet clinically significant

eJHaem | April 8, 2024 | Volume: 5 | Issue: 2 | Pages: 412-413

10.1002/jha2.893 | PMID 38633112

The impact of cytotoxic therapy on the risk of progression and death in clonal cytopenia(s) of undetermined significance

Blood Advances | April 2, 2024 | Volume: 8 | Issue: 12 | Pages: 3130-3139

10.1182/bloodadvances.2023012357 | PMID 38564774

Abstract Clonal cytopenia of undetermined significance (CCUS) is defined by a myeloid driver mutation in the context of otherwise unexplained cytopenia. CCUS has an inherent risk of progressing to myeloid neoplasm. However, it is unknown how exposure to previous cytotoxic therapy may impact the risk of progression and survival. We stratified patients with CCUS by prior exposure to DNA-damaging therapy. Of 151 patients, 46 (30%) had received cytotoxic therapy and were classified as therapy-related CCUS (t-CCUS), whereas 105 (70%) had de novo CCUS. A lower proportion of t-CCUS had hypercellular marrows (17.8% vs 44.8%, P = .002) but had higher median bone marrow blast percentages. After a median follow-up of 2.2 years, t-CCUS had significantly shorter progression-free survival (PFS, 1.8 vs 6.3 years; hazard ratio [HR], 2.1; P = .007) and median overall survival (OS; 3.6 years vs not reached; HR, 2.3; P = .007) compared with CCUS. Univariable and multivariable time-to-event analyses showed that exposure to cytotoxic therapy independently accounted for inferior PFS and OS. Despite the similarities in clinical presentation between CCUS and t-CCUS, we show that exposure to prior cytotoxic therapies was an independent risk factor for inferior outcomes. This suggests that t-CCUS represents a unique clinical entity that needs more stringent monitoring or earlier intervention strategies.
The lupus anticoagulant titer is associated with elevated antiphosphatidylserine/prothrombin immunoglobulin‐M isotype antibody levels

International Journal of Laboratory Hematology | February 21, 2024 | Volume: 46 | Issue: 4 | Pages: 695-704

10.1111/ijlh.14251 | PMID 38380742

AbstractBackgroundClot based assays used for lupus anticoagulant (LAC) detection are typically interpreted in a qualitative fashion and may not reflect LAC potency. In this cross‐sectional study, we describe a method for quantifying the LAC titer using serial (dependent) two‐fold dilutions in normal pooled plasma.MethodsSerial dilutions of 51 residual plasma samples from 50 patients were tested using the Russell's viper venom screening time (DRVVT) and activated partial thromboplastin screening time (APTT) methodologies. The measured clotting times and the corresponding dilution factors were then used to derive a four‐parameter logistic model. The LAC titer for each patient was interpolated as the sample dilution that corresponds to the upper reference interval limit of the corresponding assay.ResultsCalculated APTT and DRVVT LAC titers displayed a strong linear correlation (R2 = 0.84) between each other, but not with the degree of prolongation of the APTT/DRVVT screening time in the neat undiluted samples. Using data driven partitioning, patients could be grouped into low (<10) or high (≥10) DRVVT LAC titer. There were no significant differences in anticardiolipin (aCL) or anti‐beta 2 glycoprotein 1 (aB2GPI) antibody levels or prevalence of thromboembolic events between low and high LAC titer groups. In contrast, antiphosphatidylserine/prothrombin (aPS/PT) IgM antibody levels, but not IgG, were significantly higher in the high LAC titer group.ConclusionsThe degree of prolongation of the APTT/DRVVT screening time is not correlated with the LAC titer. Only aPS/PT IgM antibodies levels were strongly correlated with the LAC titers. Additional studies are warranted to determine clinical implications of high LAC titers.
Comprehensive morphologic characterization of bone marrow biopsy findings in a large cohort of patients with VEXAS syndrome: A single-institution longitudinal study of 111 bone marrow samples from 52 patients

American Journal of Clinical Pathology | December 22, 2023 | Volume: 161 | Issue: 6 | Pages: 609-624

10.1093/ajcp/aqad186 | PMID 38413044

Abstract Objectives VEXAS syndrome is an adult-onset autoinflammatory disease caused by a somatic pathogenic mutation in the UBA1 (ubiquitin-like modifier activating enzyme 1) gene. Patients present with rheumatologic manifestations and cytopenias and may have an increased predisposition to myelodysplastic syndrome (MDS) and plasma cell neoplasms. Prior studies have reported on the peripheral blood and bone marrow findings in patients with VEXAS syndrome. Due to the protean clinical presentation and lack of specificity of morphologic features (eg, vacuoles in early erythroid and granulocytic precursors), an optimal screening methodology to identify these patients in a timely fashion is desirable. Methods To further evaluate and describe the salient diagnostic morphologic features in VEXAS syndrome, we carried out a comprehensive study of the largest single-institution cohort to date. Diagnostic and follow-up bone marrow biopsy specimens from 52 male patients with molecularly identified VEXAS syndrome underwent central review. Results Cytopenias were common in all cases, primarily macrocytic anemia, monocytopenia, and thrombocytopenia. Bone marrow aspirate and biopsy were often hypercellular, with an increased myeloid/erythroid ratio, granulocytic hyperplasia with left shift, erythroid left shift, and megakaryocyte hyperplasia, which exhibited a range of striking morphologic findings. Distinctly vacuolated myeloid and erythroid precursors were seen in more than 95% of cases. Conclusions Our data reveal potential novel diagnostic features, such as a high incidence of monocytopenia and distinct patterns of atypical megakaryopoiesis, that appear different from dysmegakaryopoiesis typically associated with MDS. In our experience, those findings are suggestive of VEXAS, in the appropriate clinical context.
Cold platelet transfusion: The effects of a fluid warmer on platelet function

Transfusion | December 20, 2023 | Volume: 64 | Issue: 1 | Pages: 47-52

10.1111/trf.17624 | PMID 38115202

AbstractBackgroundRecently the US Food and Drug Administration has granted variances to select blood centers to supply cold‐stored platelet components (CSP). In hemorrhage resuscitation warming of blood components with approved fluid warming devices is common.Study Design and MethodsPathogen‐reduced apheresis platelet units were collected and stored in one of two ways: (1) CSP‐I, (2) CSP‐D. CSP‐I were collected and immediately stored at 1–6°C until used. CSP‐D were collected and stored at 20–24°C for 5 days and transferred to storage at 1–6°C until use. Aggregometry using arachidonic acid (AA), adenosine diphosphate (ADP) and collagen as agonists was performed on the unit samples before and after the units were infused through a Ranger blood‐warming device.ResultsCSP‐I, 23 units, had very high aggregation responses to all agonists (all ≥47.6 ± 20.7). There was a statistically significant reduction in ADP‐induced aggregometry results from 55.1 ± 23.2 before compared to 33.5 ± 14.6 following infusion of the PLT through the blood warmer (p < .001). There were no differences in AA and collagen aggregometry results before and after the infusion of the platelets through the blood warmer. CSP‐D had 5 of the 15 units with visible clotting in the bag. The 10 CSP‐Ds studied had lower aggregation than all agonists before and after infusion through the blood‐warming device (all ≤49.9 ± 35.9).ConclusionWe detected a statistically significant reduction in ADP‐induced aggregometry in CSP‐I run through a Ranger blood‐warming device with no change with AA or collagen agonist aggregometry.