Back to Authors

Christner, Jodie A.

A5085904312 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 8

Study of the Impact of the Location of a Perforator in the Perfusion of a Perforator Flap: The Concept of “Angle of Perfusion”

Journal of Reconstructive Microsurgery | September 16, 2016 | Volume: 33 | Issue: 01 | Pages: 049-058

10.1055/s-0036-1588017 | PMID 27636539

The Distally Based Dorsal Metatarsal Artery Perforator Flap: Vascular Study and Clinical Implications

Journal of Reconstructive Microsurgery | July 13, 2015 | Volume: 32 | Issue: 04 | Pages: 245-250

10.1055/s-0035-1554936 | PMID 26165886

Minimally invasive convection-enhanced delivery of biologics into dorsal root ganglia: validation in the pig model and prospective modeling in humans

Journal of Neurosurgery | July 4, 2014 | Volume: 121 | Issue: 4 | Pages: 851-858

10.3171/2014.6.jns132364 | PMID 24995785

Dorsal root ganglia (DRG) are critical anatomical structures involved in nociception. Intraganglionic (IG) drug delivery is therefore an important route of administration for novel analgesic therapies. Although IG injection in large animal models is highly desirable for preclinical biodistribution and toxicology studies of new drugs, no method to deliver pharmaceutical agents into the DRG has been reported in any large species. The present study describes a minimally invasive technique of IG agent delivery in domestic swine, one of the most common large animal models. The technique utilizes CT guidance for DRG targeting and a custom-made injection assembly for convectionenhanced delivery (CED) of therapeutic agents directly into DRG parenchyma. The DRG were initially visualized by CT myelography to determine the optimal access route to the DRG. The subsequent IG injection consisted of 3 steps. First, a commercially available guide needle was advanced to a position dorsolateral to the DRG, and the dural root sleeve was punctured, leaving the guide needle contiguous with, but not penetrating, the DRG. Second, the custom-made stepped stylet was inserted through the guide needle into the DRG parenchyma. Third, the stepped stylet was replaced by the custom-made stepped needle, which was used for the IG CED. Initial dye injections performed in pig cadavers confirmed the accuracy of DRG targeting under CT guidance. Intraganglionic administration of adeno-associated virus in vivo resulted in a unilateral transduction of the injected DRG, with 33.5% DRG neurons transduced. Transgene expression was also found in the dorsal root entry zones at the corresponding spinal levels. The results thereby confirm the efficacy of CED by the stepped needle and a selectivity of DRG targeting. Imaging-based modeling of the procedure in humans suggests that IG CED may be translatable to the clinical setting.
Dose Reduction to Anterior Surfaces With Organ-Based Tube-Current Modulation: Evaluation of Performance in a Phantom Study

American Journal of Roentgenology | August 23, 2011 | Volume: 197 | Issue: 3 | Pages: 689-695

10.2214/ajr.10.6061 | PMID 21862813

Radiation Dose Levels for Interventional CT Procedures

American Journal of Roentgenology | July 1, 2011 | Volume: 197 | Issue: 1 | Pages: W97-W103

10.2214/ajr.10.5057 | PMID 21701002

How Effective Is Effective Dose as a Predictor of Radiation Risk?

American Journal of Roentgenology | March 22, 2010 | Volume: 194 | Issue: 4 | Pages: 890-896

10.2214/ajr.09.4179 | PMID 20308487

Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning

American Journal of Roentgenology | March 22, 2010 | Volume: 194 | Issue: 4 | Pages: 881-889

10.2214/ajr.09.3462 | PMID 20308486

Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation

American Journal of Roentgenology | December 22, 2009 | Volume: 194 | Issue: 1 | Pages: W49-W55

10.2214/ajr.09.2878 | PMID 20028890