Citations 20

Use of copeptin for rapid rule-out of acute myocardial infarction

European Heart Journal: Acute Cardiovascular Care | June 8, 2017 | Volume: 7 | Issue: 6 | Pages: 570-576

10.1177/2048872617710791 | PMID 28593800

Copeptin is currently understood as a quantitative marker of endogenous stress. It rises rapidly in multiple acute disorders including acute myocardial infarction. As a single variable, it has only modest diagnostic accuracy for acute myocardial infarction. However, the use of copeptin within a dual-marker strategy together with conventional cardiac troponin increases the diagnostic accuracy and particularly the negative predictive value of cardiac troponin alone for acute myocardial infarction. The rapid rule-out of acute myocardial infarction is the only application in acute cardiac care mature enough to merit consideration for routine clinical care. However, the dual-marker approach seems to provide only very small incremental value when used in combination with sensitive or high-sensitivity cardiac troponin assays. This review aims to update and educate regarding the potential and the procedural details, as well as the caveats and challenges of using copeptin in clinical practice.
What to do when you question cardiac troponin values

European Heart Journal: Acute Cardiovascular Care | May 9, 2017 | Volume: 7 | Issue: 6 | Pages: 577-586

10.1177/2048872617708973 | PMID 28485179

High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic myocardial injury without overt myocardial ischaemia are detected than with previous cardiac troponin assays. Increased troponin concentrations that do not fit with the clinical presentation are seen in the daily routine, mainly as a result of a variety of pathologies, and if tested in the same sample, even discrepancies between high-sensitivity cardiac troponin I and troponin T test results may sometimes be found as well. In addition, analytically false-positive test results occasionally may occur since no assay is perfect. In this review, we summarise the biochemical, pathophysiological and analytical background of the work-up for such a clinical setting.
Rapid rule out of acute myocardial infarction: novel biomarker-based strategies

European Heart Journal: Acute Cardiovascular Care | July 2, 2016 | Volume: 6 | Issue: 3 | Pages: 218-222

10.1177/2048872616653229 | PMID 27370210

Editor’s Choice-Rule-in of acute myocardial infarction: Focus on troponin

European Heart Journal: Acute Cardiovascular Care | June 3, 2016 | Volume: 6 | Issue: 3 | Pages: 212-217

10.1177/2048872616653228 | PMID 27257262

Will sacubitril-valsartan diminish the clinical utility of B-type natriuretic peptide testing in acute cardiac care?

European Heart Journal: Acute Cardiovascular Care | January 13, 2016 | Volume: 6 | Issue: 4 | Pages: 321-328

10.1177/2048872615626355 | PMID 26758541

How to use D-dimer in acute cardiovascular care

European Heart Journal: Acute Cardiovascular Care | October 8, 2015 | Volume: 6 | Issue: 1 | Pages: 69-80

10.1177/2048872615610870 | PMID 26450781

In search for the Holy Grail: Suggestions for studies to define delta changes to diagnose or exclude acute myocardial infarction: a position paper from the study group on biomarkers of the Acute Cardiovascular Care Association

European Heart Journal: Acute Cardiovascular Care | July 9, 2014 | Volume: 3 | Issue: 4 | Pages: 313-316

10.1177/2048872614541906 | PMID 25009249

Diagnostic performance of rising, falling, or rising and falling kinetic changes of high-sensitivity cardiac troponin T in an unselected emergency department population

European Heart Journal: Acute Cardiovascular Care | July 16, 2013 | Volume: 2 | Issue: 4 | Pages: 314-322

10.1177/2048872613498517 | PMID 24338290

Interpreting Changes in Troponin—Clinical Judgment Is Essential

Clinical Chemistry | December 28, 2011 | Volume: 58 | Issue: 1 | Pages: 39-43

10.1373/clinchem.2011.173138 | PMID 22205772

Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay

Clinical Chemistry | December 3, 2009 | Volume: 56 | Issue: 2 | Pages: 254-261

10.1373/clinchem.2009.132654 | PMID 19959623

Abstract Background: We report the development of a novel high-sensitivity cardiac troponin T (hs-cTnT) assay, a modification of the Roche fourth-generation cTnT assay, and validation of the analytical performance of this assay. Methods: Validation included testing of analytical sensitivity, specificity, interferences, and precision. We established the 99th percentile cutoff from healthy reference populations (n = 616). In addition, we studied differences in time to a positive result when using serial measurements of hs-cTnT vs cTnT in patients with a confirmed diagnosis of non-ST elevation myocardial infarction (non-STEMI). Results: The hs-cTnT assay had an analytical range from 3 to 10 000 ng/L. At the 99th percentile value of 13.5 ng/L, the CV was 9% using the Elecsys® 2010 analyzer. The assay was specific for cTnT without interferences from human cTnI or cTnC, skeletal muscle TnT, or hemoglobin concentrations up to 1000 mg/L, above which falsely lower values would be expected. When the assay was evaluated clinically, a hs-cTnT higher than the 99th percentile concentration identified a significantly higher number of patients with non-STEMI on presentation (45 vs 20 patients, P = 0.0004) compared with cTnT, and a final diagnosis of non-STEMI was made in 9 additional patients (55 vs 46 patients, P = 0.23) after serial sampling. Time to diagnosis was significantly shorter using hs-cTnT compared with cTnT [mean 71.5 (SD 108.7) min vs 246.9 (82.0) min, respectively; P < 0.01]. Conclusions: The analytical performance of hs-cTnT complies with the ESC-ACCF-AHA-WHF Global Task Force recommendations for use in the diagnosis of MI.