Citations 386

Left Axis Deviation in Children Without Previously Known Heart Disease

Pediatrics | February 1, 2018 | Volume: 141 | Issue: 3 | Pages: No page available

10.1542/peds.2017-1970 | PMID 29437138

BACKGROUND: Left axis deviation (LAD) discovered in children via electrocardiogram (ECG) is uncommon but can be associated with heart disease (HD). The optimal diagnostic approach in a seemingly healthy child with LAD is unclear. We sought to better stratify which patients with LAD but without previously known HD may warrant additional workup. METHODS: A retrospective chart review was performed to identify patients ≥1 to <18 years of age with LAD (QRS frontal plane axis 0 to −90) on an ECG between January 2002 and December 2014. Patients with known HD before their initial ECG were excluded. RESULTS: Overall, 296 patients were identified (n = 181 [61%] male; mean age: 10.8 ± 4.6 years; mean QRS axis: −24 ± 22°). An echocardiogram was performed in 158 (53%) patients, with 24 (15%) having HD. Compared with those with an echocardiogram but without HD (n = 134), patients with HD had a more negative mean QRS axis (−42 vs −27°; P = .002) and were more likely to have a QRS axis ≤−42° (58% vs 26%; P = .003), ECG chamber enlargement or hypertrophy (38% vs 5%; P < .0001), and abnormal cardiac physical examination findings (75% vs 8%; P < .0001). CONCLUSIONS: LAD discovered in isolation in the asymptomatic pediatric patient may not necessitate further cardiovascular investigation. Clinicians should consider obtaining an echocardiogram in patients with LAD and ECG cardiac chamber enlargement or hypertrophy, a QRS axis ≤−42°, and/or the presence of abnormal cardiac physical examination findings.
Technical Advances for the Clinical Genomic Evaluation of Sudden Cardiac Death

Circulation: Cardiovascular Genetics | December 13, 2017 | Volume: 10 | Issue: 6 | Pages: No page available

10.1161/circgenetics.117.001844 | PMID 29237689

Background— Postmortem genetic testing for heritable cardiovascular (CV) disorders is often lacking because ideal specimens (ie, whole blood) are not retained routinely at autopsy. Formalin-fixed paraffin-embedded tissue (FFPET) is ubiquitously collected at autopsy, but DNA quality hampers its use with traditional sequencing methods. Targeted next-generation sequencing may offer the ability to circumvent such limitations, but a method has not been previously described. The primary aim of this study was to develop and evaluate the use of FFPET for heritable CV disorders via next-generation sequencing. Methods and Results— Nineteen FFPET (heart) and blood (whole blood or dried blood spot) specimens underwent targeted next-generation sequencing using a custom panel of 101 CV-associated genes. Nucleic acid yield and quality metrics were evaluated in relation to FFPET specimen age (6 months to 15 years; n=14) and specimen type (FFPET versus whole blood and dried blood spot; n=12). Four FFPET cases with a clinical phenotype of heritable CV disorder were analyzed. Accuracy and precision were 100% concordant between all sample types, with read depths >100× for most regions tested. Lower read depth, as low as 40×, was occasionally observed with FFPET and dried blood spot. High-quality DNA was obtained from FFPET samples as old as 15 years. Genomic analysis of FFPET from the 4 phenotype-positive/genotype unknown cases all revealed putative disease-causing variants. Conclusions— Similar performance characteristics were observed for next-generation sequencing of FFPET, whole blood, and dried blood spot in the evaluation of inherited CV disorders. Although blood is preferable for genetic analyses, this study offers an alternative when only FFPET is available.
Irritable bowel syndrome patients haveSCN5Achannelopathies that lead to decreased NaV1.5 current and mechanosensitivity

American Journal of Physiology-Gastrointestinal and Liver Physiology | November 22, 2017 | Volume: 314 | Issue: 4 | Pages: G494-G503

10.1152/ajpgi.00016.2017 | PMID 29167113

The SCN5A-encoded voltage-gated mechanosensitive Na+channel NaV1.5 is expressed in human gastrointestinal smooth muscle cells and interstitial cells of Cajal. NaV1.5 contributes to smooth muscle electrical slow waves and mechanical sensitivity. In predominantly Caucasian irritable bowel syndrome (IBS) patient cohorts, 2–3% of patients have SCN5A missense mutations that alter NaV1.5 function and may contribute to IBS pathophysiology. In this study we examined a racially and ethnically diverse cohort of IBS patients for SCN5A missense mutations, compared them with IBS-negative controls, and determined the resulting NaV1.5 voltage-dependent and mechanosensitive properties. All SCN5A exons were sequenced from somatic DNA of 252 Rome III IBS patients with diverse ethnic and racial backgrounds. Missense mutations were introduced into wild-type SCN5A by site-directed mutagenesis and cotransfected with green fluorescent protein into HEK-293 cells. NaV1.5 voltage-dependent and mechanosensitive functions were studied by whole cell electrophysiology with and without shear force. Five of 252 (2.0%) IBS patients had six rare SCN5A mutations that were absent in 377 IBS-negative controls. Six of six (100%) IBS-associated NaV1.5 mutations had voltage-dependent gating abnormalities [current density reduction (R225W, R433C, R986Q, and F1293S) and altered voltage dependence (R225W, R433C, R986Q, G1037V, and F1293S)], and at least one kinetic parameter was altered in all mutations. Four of six (67%) IBS-associated SCN5A mutations (R225W, R433C, R986Q, and F1293S) resulted in altered NaV1.5 mechanosensitivity. In this racially and ethnically diverse cohort of IBS patients, we show that 2% of IBS patients harbor SCN5A mutations that are absent in IBS-negative controls and result in NaV1.5 channels with abnormal voltage-dependent and mechanosensitive function.NEW & NOTEWORTHY The voltage-gated Na+channel NaV1.5 contributes to smooth muscle physiology and electrical slow waves. In a racially and ethnically mixed irritable bowel syndrome cohort, 2% had mutations in the NaV1.5 gene SCN5A. These mutations were absent in irritable bowel syndrome-negative controls. Most mutant NaV1.5 channels were loss of function in voltage dependence or mechanosensitivity.
Architectural T-Wave Analysis and Identification of On-Therapy Breakthrough Arrhythmic Risk in Type 1 and Type 2 Long-QT Syndrome

Circulation: Arrhythmia and Electrophysiology | November 16, 2017 | Volume: 10 | Issue: 11 | Pages: No page available

10.1161/circep.117.005648 | PMID 29141844

Background: Although the hallmark of long-QT syndrome (LQTS) is abnormal cardiac repolarization, there are varying degrees of phenotypic expression and arrhythmic risk. Our aim was to evaluate the performance of a morphological T-wave analysis program in defining breakthrough LQTS arrhythmic risk beyond the QTc value. Methods and Results: We analyzed 407 genetically confirmed patients with LQT1 (n=246; 43% men) and LQT2 (n=161; 41% men) over the mean follow-up period of 6.4±3.9 years. ECG analysis was conducted using a novel, proprietary T-wave analysis program. Time to a LQTS-associated cardiac event was analyzed using Cox proportional hazards regression methods. Twenty-three patients experienced ≥1 defined breakthrough cardiac arrhythmic events with 5- and 10-year event rates of 4% and 7%. Two independent predictors of future LQTS-associated cardiac events from the surface ECG were identified: left slope of T wave in lead V6 (hazard ratio=0.40 [0.24–0.69]; P <0.001) and T-wave center of gravity x axis (last 25% of wave) in lead I (hazard ratio=1.90 [1.21–2.99]; P =0.005), C statistic of 0.77 (0.65–0.89). When added to the QTc (C statistic 0.68 for QTc alone), discrimination improved to 0.78. Genotype analysis showed weaker association between these T-wave variables and LQT1-triggered events while these features were stronger in patients with LQT2 and significantly outperformed the QTc (C statistic, 0.82 [0.71–0.93]). Conclusion: Detailed morphological analysis of the T wave provides novel insights into risk of breakthrough arrhythmic events in LQTS, particularly LQT2. This observation has the potential to guide clinical decision making and further refine risk stratification.
Competitive Sport Participation Among Athletes With Heart Disease

Circulation | October 23, 2017 | Volume: 136 | Issue: 17 | Pages: 1569-1571

10.1161/circulationaha.117.029639 | PMID 29061571

Genomic Triangulation and Coverage Analysis in Whole-Exome Sequencing–Based Molecular Autopsies

Circulation: Cardiovascular Genetics | October 7, 2017 | Volume: 10 | Issue: 5 | Pages: No page available

10.1161/circgenetics.117.001828 | PMID 28986455

Background— WEMA (Whole-Exome Molecular Autopsy) and surveillance of cardiac channelopathy and cardiomyopathy genes represents the latest molecular autopsy for sudden death in the young (SDY). To date, the majority of WEMA has been performed on the SDY case only. Methods and Results— We performed whole-exome sequencing and nucleotide-level coverage analysis on 28 SDY cases (18.4±7.8 years) and their parents to determine the inheritance patterns of ultrarare, nonsynonymous variants in 99 sudden death–susceptibility genes. Nonsynonymous variants were adjudicated using the American College of Medical Genetics guidelines. Overall, 17 sudden death–susceptibility gene variants were identified in 12 of 28 (43%) SDY cases. On the basis of the American College of Medical Genetics guidelines, 6 of 28 (21%) cases had a pathogenic or likely pathogenic nonsynonymous variant with 3 (50%) being de novo. Two nonsynonymous variants would not have been elevated to likely pathogenic status without knowing their de novo status. Whole-exome sequencing reached a read depth of 10× across 90% of nucleotides within sudden death–susceptibility genes in 100% of parental exomes from fresh blood draw, compared with only 82% of autopsy-sourced SDY exomes. Conclusions— An SDY-parent, trio-based WEMA may be an effective way of elucidating a monogenic cause of death and bringing clarity to otherwise ambiguous variants. If other studies confirm this relatively high rate of SDY cases stemming from de novo mutations, then the WEMA should become even more cost-effective given that the decedent’s first-degree relatives should only need minimal cardiological evaluation. In addition, autopsy-sourced DNA demonstrated strikingly lower whole-exome sequencing coverage than DNA from fresh blood draw.
Whole genome sequencing identifies etiology of recurrent male intrauterine fetal death

Prenatal Diagnosis | August 18, 2017 | Volume: 37 | Issue: 10 | Pages: 1040-1045

10.1002/pd.5142 | PMID 28833278

AbstractObjectiveTo identify the underlying genetic cause for recurrent intrauterine fetal death (IUFD) of males.MethodsWhole genome sequencing was performed on DNA from five healthy obligatory carrier females and an unaffected male offspring of a multigenerational pedigree with recurrent second‐trimester IUFD of males (n = 19). When documented, all deaths occurred at ≤20 weeks of gestation. Hydrops fetalis was diagnosed at death in the most recent case.ResultsFollowing variant filtering based on a recessive X‐linked inheritance pattern, a rare FOXP3 frameshift mutation (p.D303fs*87) that results in a premature truncation of the protein was discovered. Sanger sequencing confirmed the mutation in the affected fetus. The FOXP3 gene encodes for a transcriptional regulator critical to the function of regulatory T cells. FOXP3 mutations are associated with immune dysregulation, polyendocrinopathy, enteropathy, and X‐linked (IPEX) syndrome which exclusively affects males and may present with a potentially life‐threatening complex autoimmune disorder in early childhood.ConclusionsHere, we demonstrate the utility of whole genome sequencing‐based pedigree analysis to identify the genetic cause for recurrent IUFD when chromosome studies, including microarray analysis, are normal. Further studies are needed to determine the prevalence of FOXP3‐mediated IUFD in males. © 2017 John Wiley & Sons, Ltd.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators

Circulation | June 5, 2017 | Volume: 135 | Issue: 23 | Pages: 2310-2312

10.1161/circulationaha.117.027828 | PMID 28584032

2SDP-04 The nature of myocardial heart failure : Are hypertrophic cardiomyopathies all the same?(2SDP ASB-BSJ Bilateral Symposium 2013,Symposium,The 51th Annual Meeting of the Biophysical Society of Japan)

Seibutsu Butsuri | May 5, 2017 | Volume: 53 | Issue: supplement1-2 | Pages: S99

10.2142/biophys.53.s99_4

Automated T‐wave analysis can differentiate acquired QT prolongation from congenital long QT syndrome

Annals of Noninvasive Electrocardiology | April 21, 2017 | Volume: 22 | Issue: 6 | Pages: No page available

10.1111/anec.12455 | PMID 28429460

BackgroundProlongation of the QT on the surface electrocardiogram can be due to either genetic or acquired causes. Distinguishing congenital long QT syndrome (LQTS) from acquired QT prolongation has important prognostic and management implications. We aimed to investigate if quantitative T‐wave analysis could provide a tool for the physician to differentiate between congenital and acquired QT prolongation.MethodsPatients were identified through an institution‐wide computer‐based QT screening system which alerts the physician if the QTc ≥ 500 ms. ECGs were retrospectively analyzed with an automated T‐wave analysis program. Congenital LQTS was compared in a 1:3 ratio to those with an identified acquired etiology for QT prolongation (electrolyte abnormality and/or prescription of known QT prolongation medications). Linear discriminant analysis was performed using 10‐fold cross‐validation to statistically test the selected features.ResultsThe 12‐lead ECG of 38 patients with congenital LQTS and 114 patients with drug‐induced and/or electrolyte‐mediated QT prolongation were analyzed. In lead V5, patients with acquired QT prolongation had a shallower T wave right slope (−2,322 vs. −3,593 mV/s), greater T‐peak‐Tend interval (109 vs. 92 ms), and smaller T wave center of gravity on the x axis (290 ms vs. 310 ms; p < .001). These features could distinguish congenital from acquired causes in 77% of cases (sensitivity 90%, specificity 58%).ConclusionT‐wave morphological analysis on lead V5 of the surface ECG could successfully differentiate congenital from acquired causes of QT prolongation.