Citations 245

Comparison of arterial mechanical properties measured with arterial dispersion ultrasound vibrometry and clinical arterial stiffness metrics

The Journal of the Acoustical Society of America | November 28, 2022 | Volume: 152 | Issue: 4_Supplement | Pages: A47-A47

10.1121/10.0015495

Arterial stiffness is recognized as a highly clinically relevant and independent prognostic biomarker of cardiovascular disease. Arterial dispersion ultrasound vibrometry (ADUV) uses acoustic radiation force to generate propagating waves in the arterial wall and measures the wave motion to estimate arterial mechanical properties from fitting phase velocity dispersion curves to a waveguide model. ADUV measurements were made with a Verasonics V1 system with a L7-4 linear array transducer in 63 human subjects (27 male/36 female) from ages 50–88 years old. We made measurements at 10 time points within the cardiac cycle, termed cardiac stages. We estimated the phase velocity (median of cp from 400-600 Hz) and G determined from matching the dispersion curves with those from a waveguide model incorporating the artery diameter and wall thickness. Within the same study visit, we measured the intima-media thickness and diameter changes through the cardiac cycle with a General Electric Logiq E9 or E10 scanner. We also tonometry to determine the carotid-femoral pulse wave velocity. We report here comparisons of median phase velocity, cp, and inverted shear modulus, G, at different stages of the cardiac cycle with clinical metrics of arterial stiffness.
Development of a Machine Learning Model Using Electrocardiogram Signals to Determine Acute Pulmonary Embolism

Blood | November 28, 2022 | Volume: 140 | Issue: Supplement 1 | Pages: 8511-8512

10.1182/blood-2022-163369

Screening for cardiac allograft rejection among heart transplant recipients using an electrocardiogram-based deep learning model

European Heart Journal | October 14, 2022 | Volume: 43 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehac544.1020

Abstract Background Current approaches utilizing non-invasive methods to screen for cardiac allograft rejection (gene expression profiling and cell free DNA) have yet to be broadly integrated into heart transplant management and have shown limited discrimination (AUCs of 0.68 and 0.77, respectively). Changes in the electrocardiogram (ECG) have been reported at the time of severe cardiac rejection, including low voltages and conduction abnormalities. It remains unknown if subtle ECG changes correlating with cardiac allograft rejection can be detected earlier using machine learning methods. Purpose We sought to develop an artificial intelligence (AI) model to detect cardiac allograft rejection based on the 12 lead ECG. Methods We identified all patients who underwent a heart transplant at 3 hospital sites within a single health system from Jan 1998 through Apr 2021 and extracted digital 12-lead ECG data as well as endomyocardial biopsy pathology results from the electronic medical record. We partitioned our data into a training (80%), validation (10%), and test set (10%) based on a group stratification sampling. Each patient was present in only one set and each set had a positivity rate of 2.6% with 6,074/758/758 ECGs belonging to 1,146/140/141 unique patients in each set respectively. Cardiac allograft rejection was defined as moderate or severe acute cellular rejection based on International Society for Heart and Lung Transplantation (ISHLT) guidelines. A convolutional neural network, using the 12-lead ECG data as input, was trained with hyperparameter optimization for regularization, learning rate adjustments, and class weights. Model performance metrics were based on the test data and estimated using the final model architecture. Results 1,587 heart transplant recipients who had at least one endomyocardial biopsy were evaluated for inclusion. We limited our sample to ECGs performed within 30 days of the biopsy date (7,590 ECGs, representing 1,425 unique patients). Our study population had a median age of 55.8 years and 28.7% were female. The median number of ECG-biopsy pairs per patient was 5. The majority of endomyocardial biopsy results were classified as none or mild rejection (97.1%), and 2.9% had moderate/severe rejection. The ECG-based AI model detected cardiac allograft rejection with an area under the receiver operative curve (AUC) of 0.84 in the test set. The sensitivity, specificity, positive and negative predictive values were 95%, 52.6%. 5.2% and 99.7% respectively. Conclusions An AI-ECG model appears to outperform novel non-invasive laboratory tests (gene expression profiling and cell free DNA) for detecting cardiac allograft rejection and does not require a blood draw or the additional complexities surrounding sample processing. This model relies on a readily available and relatively inexpensive test, the ECG. In addition, AI predictions can be made available within a few minutes following ECG acquisition. Funding Acknowledgement Type of funding sources: Private hospital(s). Main funding source(s): Mayo Clinic
Cardiac Rehabilitation Completion Study: Barriers and Potential Solutions

Journal of Cardiopulmonary Rehabilitation and Prevention | August 31, 2022 | Volume: 42 | Issue: 5 | Pages: 375-377

10.1097/hcr.0000000000000709 | PMID 36044761

Deep learning-derived cardiovascular age shares a genetic basis with other cardiac phenotypes

No container title available | August 29, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1735746/v1

Abstract Artificial intelligence (AI)-based approaches can now use electrocardiograms (ECGs) to provide expert-level performance in detecting heart abnormalities and diagnosing disease. Additionally, patient age predicted from ECGs by AI models has shown great potential as a biomarker for cardiovascular age as recent work has found differences from chronological age ("delta age") to be associated with mortality and co-morbidities. However, the genetic underpinning of delta age is unknown, but crucial for understanding underlying individual risk. By performing a genome-wide association study using UK Biobank data (n=34,432), we identified eight loci associated with delta age (p ≤ 5 × 10−8 ), including genes linked to cardiovascular disease (CVD) (e.g. SCN5A) and (heart) muscle development (e.g. TTN). Our results indicate that the genetic basis of cardiovascular ageing is predominantly determined by genes directly involved with the cardiovascular system rather than those connected to more general mechanisms of ageing. Our insights inform the epidemiology of CVD, with implications for preventative and precision medicine.
Obesity and cardiovascular disease: mechanistic insights and management strategies. A joint position paper by the World Heart Federation and World Obesity Federation

European Journal of Preventive Cardiology | August 24, 2022 | Volume: 29 | Issue: 17 | Pages: 2218-2237

10.1093/eurjpc/zwac187 | PMID 36007112

Abstract The ongoing obesity epidemic represents a global public health crisis that contributes to poor health outcomes, reduced quality of life, and >2.8 million deaths each year. Obesity is relapsing, progressive, and heterogeneous. It is considered a chronic disease by the World Obesity Federation (WOF) and a chronic condition by the World Heart Federation (WHF). People living with overweight/obesity are at greater risk for cardiovascular (CV) morbidity and mortality. Increased adiposity (body fat), particularly visceral/abdominal fat, is linked to CV risk and CV disease (CVD) via multiple direct and indirect pathophysiological mechanisms. The development of CVD is driven, in part, by obesity-related metabolic, endocrinologic, immunologic, structural, humoral, haemodynamic, and functional alterations. The complex multifaceted nature of these mechanisms can be challenging to understand and address in clinical practice. People living with obesity and CVD often have concurrent chronic physical or psychological disorders (multimorbidity) requiring multidisciplinary care pathways and polypharmacy. Evidence indicates that intentional weight loss (particularly when substantial) lowers CVD risk among people with overweight/obesity. Long-term weight loss and maintenance require ongoing commitment from both the individual and those responsible for their care. This position paper, developed by the WOF and the WHF, aims to improve understanding of the direct and indirect links between overweight/obesity and CVD, the key controversies in this area and evidence relating to cardiometabolic outcomes with available weight management options. Finally, an action plan for clinicians provides recommendations to help in identifying and addressing the risks of obesity-related CVD (recognizing resource and support variances between countries).
Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope

European Heart Journal - Digital Health | May 23, 2022 | Volume: 3 | Issue: 3 | Pages: 373-379

10.1093/ehjdh/ztac030 | PMID 36712160

Abstract Aims Electrocardiogram (ECG)-enabled stethoscope (ECG-Scope) acquires a single-lead ECGs during cardiac auscultation and may facilitate real-time screening for pathologies not routinely identified by cardiac auscultation alone. We previously demonstrated an artificial intelligence (AI) algorithm can identify left ventricular dysfunction (LVSD) [defined as ejection fraction (EF) ≤ 40%] with an area under the curve (AUC) of 0.91 using a 12-lead ECG. Methods and results One hundred patients referred for clinically indicated echocardiography were prospectively recruited. ECG-Scope recordings with the patient supine and sitting were obtained in multiple electrode locations at the time of the echocardiogram. The AI algorithm for the detection of LVSD was retrained using single leads from ECG-12 and validated against ECG-Scope to determine accuracy for low EF detection (≤35%, <40%, or <50%). We evaluated the algorithm with respect to body position and lead location. Amongst 100 patients (aged 61.3 ± 13.8; 61% male, BMI: 30.0 ± 5.4), eight had EF≤40%, and six had EF 40–50%. The best single recording position was V2 with the patient supine [AUC: 0.88 (CI: 0.80–0.97) for EF≤35%, 0.85 (CI: 0.75–0.95) for EF≤40%, and 0.81 (CI: 0.71–0.90) for EF < 50%]. When using an AI model to select the recording automatically, AUC was 0.91 (CI: 0.84–0.97) for EF≤35%, 0.89 (CI: 0.83–0.96) for EF≤40%, and 0.84 (CI: 0.73–0.94) for EF < 50%. Conclusion An AI algorithm applied to an ECG-enabled stethoscope recording in standard auscultation positions reliably detected the presence of a low EF in this prospective study of patients referred for echocardiography. The ability to screen patients with a possible low EF during routine physical examination may facilitate rapid detection of LVSD.
Real-world performance, long-term efficacy, and absence of bias in the artificial intelligence enhanced electrocardiogram to detect left ventricular systolic dysfunction

European Heart Journal - Digital Health | May 17, 2022 | Volume: 3 | Issue: 2 | Pages: 238-244

10.1093/ehjdh/ztac028 | PMID 36247412

Abstract Aims Some artificial intelligence models applied in medical practice require ongoing retraining, introduce unintended racial bias, or have variable performance among different subgroups of patients. We assessed the real-world performance of the artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction with respect to multiple patient and electrocardiogram variables to determine the algorithm’s long-term efficacy and potential bias in the absence of retraining. Methods and results Electrocardiograms acquired in 2019 at Mayo Clinic in Minnesota, Arizona, and Florida with an echocardiogram performed within 14 days were analyzed (n = 44 986 unique patients). The area under the curve (AUC) was calculated to evaluate performance of the algorithm among age groups, racial and ethnic groups, patient encounter location, electrocardiogram features, and over time. The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction had an AUC of 0.903 for the total cohort. Time series analysis of the model validated its temporal stability. Areas under the curve were similar for all racial and ethnic groups (0.90–0.92) with minimal performance difference between sexes. Patients with a ‘normal sinus rhythm’ electrocardiogram (n = 37 047) exhibited an AUC of 0.91. All other electrocardiogram features had areas under the curve between 0.79 and 0.91, with the lowest performance occurring in the left bundle branch block group (0.79). Conclusion The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction is stable over time in the absence of retraining and robust with respect to multiple variables including time, patient race, and electrocardiogram features.
Artificial intelligence for the evaluation of peripheral artery disease using arterial Doppler waveforms to predict abnormal ankle-brachial index

Vascular Medicine | May 10, 2022 | Volume: 27 | Issue: 4 | Pages: 333-342

10.1177/1358863x221094082 | PMID 35535982

Background: Patients with peripheral artery disease (PAD) are at increased risk for major adverse limb and cardiac events including mortality. Developing screening tools capable of accurate PAD identification is a necessary first step for strategies of adverse outcome prevention. This study aimed to determine whether machine analysis of a resting Doppler waveform using deep neural networks can accurately identify patients with PAD. Methods: Consecutive patients (4/8/2015 – 12/31/2020) undergoing rest and postexercise ankle–brachial index (ABI) testing were included. Patients were randomly allocated to training, validation, and testing subsets (70%/15%/15%). Deep neural networks were trained on resting posterior tibial arterial Doppler waveforms to predict normal (> 0.9) or PAD (⩽ 0.9) using rest and postexercise ABI. A separate dataset of 151 patients who underwent testing during a period after the model had been created and validated (1/1/2021 – 3/31/2021) was used for secondary validation. Area under the receiver operating characteristic curves (AUC) were constructed to evaluate test performance. Results: Among 11,748 total patients, 3432 patients met study criteria: 1941 with PAD (mean age 69 ± 12 years) and 1491 without PAD (64 ± 14 years). The predictive model with highest performance identified PAD with an AUC 0.94 (CI = 0.92–0.96), sensitivity 0.83, specificity 0.88, accuracy 0.85, and positive predictive value (PPV) 0.90. Results were similar for the validation dataset: AUC 0.94 (CI = 0.91–0.98), sensitivity 0.91, specificity 0.85, accuracy 0.89, and PPV 0.89 (postexercise ABI comparison). Conclusion: An artificial intelligence-enabled analysis of a resting Doppler arterial waveform permits identification of PAD at a clinically relevant performance level.
Artificial intelligence—electrocardiography to detect atrial fibrillation: trend of probability before and after the first episode

European Heart Journal - Digital Health | May 9, 2022 | Volume: 3 | Issue: 2 | Pages: 228-235

10.1093/ehjdh/ztac023 | PMID 36713006

Abstract Aims Artificial intelligence (AI) enabled electrocardiography (ECG) can detect latent atrial fibrillation (AF) in patients with sinus rhythm (SR). However, the change of AI-ECG probability before and after the first AF episode is not well characterized. We sought to characterize the temporal trend of AI-ECG AF probability around the first episode of AF. Methods and results We retrospectively studied adults who had at least one ECG in SR prior to an ECG that documented AF. An AI network calculated the AF probability from ECGs during SR (positive defined >8.7%, based on optimal sensitivity and specificity). The AI-ECG probability was reported prior to and after the first episode of AF and stratified by age and CHA2DS2-VASc score. Mixed effect models were used to assess the rate of change between time points. A total of 59 212 patients with 544 330 ECGs prior to AF and 413 486 ECGs after AF were included. The mean time between the first positive AI-ECG and first AF was 5.4 ± 5.7 years. The mean AI-ECG probability was 19.8% 2–5 years prior to AF, 23.6% 1–2 years prior to AF, 34.0% 0–3 months prior to AF, 40.9% 0–3 months after AF, 35.2% 1–2 years after AF, and 42.2% 2–5 years after AF (P < 0.001). The rate of increase prior to AF was higher for age >50 years CHA2DS2-VASc score ≥4. Conclusion The AI-ECG probability progressively increases with time prior to the first AF episode, transiently decreases 1–2 years following AF and continues to increase thereafter.