Five-year outcomes of transcatheter mitral valve replacement in patients with severe symptomatic mitral regurgitation: results from the Tendyne Expanded Clinical Study
ESC Heart Failure | June 25, 2026 | Volume: 13 | Issue: 4 | Pages: No page available
Abstract Aims Transcatheter mitral valve replacement (TMVR) with the Tendyne Mitral Valve System is a treatment option for patients with severe symptomatic mitral regurgitation (MR) unsuitable for conventional mitral valve surgery or transcatheter edge-to-edge repair (TEER). This study sought to evaluate the safety and effectiveness of TMVR through 5-year follow-up. Methods and Results The Tendyne Expanded Clinical Study is a prospective, single-arm, multicentre study that enrolled patients between November 2014 and June 2020. The study enrolled 191 patients (mean age 74.1 ± 8.0 years, 62.8% male, 70.2% New York Heart Association Class (NYHA) class III/IV, 88.5% secondary MR), of whom 186 (97.4%) underwent TMVR with Tendyne. MR grade decreased from ≥3+ in 99.5% patients at baseline to grade ≤1+ in 95.3% at 5 years. In those patients surviving to 5 years (n = 49), durable symptomatic improvement was evidenced by 73.5% patients being in NYHA class I/II at 5 years. The Kansas City Cardiomyopathy Questionnaire overall summary score increased from 48.5 ± 22.5 points at baseline to 67.6 ± 21.5 points at 5 years. Serious adverse events that occurred through 5 years included life-threatening bleeding (11.5%), fatal bleeding (2.6%), renal insufficiency/failure (28.8%), endocarditis (7.3%), device thrombosis (5.8%), and new onset atrial fibrillation (13.1%). No structural device degeneration or device embolism occurred through 5 years. Conclusions The Tendyne TMVR was effective at achieving immediate and sustainable elimination of MR, which was associated with symptomatic improvement and absence of structural valve degeneration in a high-risk cohort over 5 years. These findings support TMVR with the Tendyne System as an alternative for patients with appropriate mitral valve anatomy and symptomatic secondary MR unsuitable for mitral surgery or TEER.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.