Back to Authors

Philpott, Jonathan M.

https://orcid.org/0000-0001-6493-0061

A5103105648 | I1285541721

Mayo Clinic

Sentara Norfolk General Hospital

Citations 3

Transplantation Outcomes with Donor Hearts after Circulatory Death

New England Journal of Medicine | June 7, 2023 | Volume: 388 | Issue: 23 | Pages: 2121-2131

10.1056/nejmoa2212438 | PMID 37285526

Multicenter Registry Using Propensity Score Analysis to Compare a Novel Transport/Preservation System to Traditional Means on Postoperative Hospital Outcomes and Costs for Heart Transplant Patients

ASAIO Journal | November 18, 2022 | Volume: 69 | Issue: 4 | Pages: 345-349

10.1097/mat.0000000000001844 | PMID 36399786

The standard method for cardiac allograft preservation for the past 50 years has been static storage using crushed ice. A heart transplant transportation system designed to improve preservation quality with temperature monitoring, the Paragonix SherpaPak Cardiac Transport System (SCTS), was evaluated for its impact on postoperative costs relative to conventional ice storage. Observational US multicenter registry data collected during the August 2015 to November 2021 timeframe from 12 transplant hospitals were analyzed using logistic regression analysis and propensity matching to balance measured baseline covariates and to reduce selection bias. Hospital cost and outcome data post-transplant were then evaluated using various statistical methods. One hundred seventy-four (174) patients were identified resulting in 87 matches. Baseline characteristics were similar between groups. The SCTS group had a significantly lower proportion of ICU days on post-transplant mechanical circulatory support ( p < 0.0001); significantly fewer patients on extracorporeal membrane oxygenation ( p = 0.017); and significantly fewer patients experiencing severe primary graft dysfunction (PGD) ( p = 0.03). Overall hospital plus mechanical circulatory support post-transplant costs were significantly lower by $26.7K in the CTS cohort ( p = 0.03). Use of the SCTS is associated with improved clinical outcomes resulting in significantly lower overall hospital care costs.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients

JAMA Cardiology | August 24, 2022 | Volume: 7 | Issue: 10 | Pages: 1000

10.1001/jamacardio.2022.2695 | PMID 36001335

Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &amp;lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &amp;lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &amp;lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.