COVID-19 convalescent plasma (CCP) was one of the first therapeutic options available for the treatment of SARS-CoV-2 infections and continues to be used selectively for immunosuppressed patients. Given the emergence of novel SARS-CoV-2 variants which are resistant to treatment with available monoclonal antibody (MAb) therapy, CCP remains an important therapeutic consideration.
Embracing a curiosity‐driven approach in the microneurographic exploration of the human vagus nerves
The Journal of Physiology | May 27, 2022 | Volume: 600 | Issue: 13 | Pages: 3009-3010
New Findings What is the central question of this study? Do humans with high‐affinity haemoglobin (HAH) demonstrate attenuated skeletal muscle deoxygenation during normoxic and hypoxic exercise? What is the main finding and its importance? Examination of near‐infrared spectroscopy‐derived muscle oxygenation profiles suggests that fractional oxygen extraction is blunted during hypoxic exercise in humans with HAH compared with control subjects. However, muscle tissue oxygen saturation levels were higher in humans with HAH during exercise in normoxia compared with control subjects. These alterations in fractional oxygen extraction in humans with HAH might influence blood flow regulation and exercise capacity during hypoxia. AbstractRecently, researchers in our laboratory have shown that humans with genetic mutations resulting in high‐affinity haemoglobin (HAH) demonstrate better maintained aerobic capacity and peak power output during hypoxic exercise versus normoxic exercise in comparison to humans with normal‐affinity haemoglobin. However, the influence of HAH on tissue oxygenation within exercising muscle during normoxia and hypoxia is unknown. Therefore, we examined near‐infrared spectroscopy‐derived oxygenation profiles of the vastus lateralis during graded cycling exercise in normoxia and hypoxia among humans with HAH (n = 5) and control subjects with normal‐affinity haemoglobin (n = 12). The HAH group elicited a blunted increase of deoxygenated haemoglobin + myoglobin during hypoxic exercise compared with the control group (P = 0.03), suggesting reduced fractional oxygen extraction in the HAH group. In addition, the HAH group maintained a higher level of muscle tissue oxygen saturation during normoxic exercise (HAH, 75 ± 4% vs. controls, 65 ± 3%, P = 0.049) and there were no differences between groups in muscle tissue oxygen saturation during hypoxic exercise (HAH, 68 ± 3% vs. controls, 68 ± 2%, P = 0.943). Overall, our results suggest that humans with HAH might demonstrate divergent patterns of fractional oxygen extraction during hypoxic exercise and elevated muscle tissue oxygenation during normoxic exercise compared with control subjects.
Cardiac baroreflex sensitivity and heart rate variability are lower in humans with high affinity hemoglobin compared to typical affinity hemoglobin
The FASEB Journal | May 3, 2022 | Volume: 36 | Issue: S1 | Pages: No page available
Background Humans with high O 2 affinity hemoglobin (HAH) have a markedly lower partial pressure of O 2 at which 50% of hemoglobin is saturated (P 50 ) and a leftward shift of the oxy‐hemoglobin dissociation curve. Humans with HAH have attenuated heart rate responses during both acute and chronic hypoxic exposure relative to humans with typical P 50 . Despite the attenuated heart rate responses to hypoxia, there are typically no blood pressure differences found in humans with HAH relative to humans with typical P 50 . Due to the blunted heart rate and normal blood pressure responses to hypoxia in humans with HAH, this study aimed to investigate the impact of HAH on cardiac autonomic function during normoxia and hypoxia. We hypothesized that humans with HAH would have lower cardiac baroreflex sensitivity (cBRS) and heart rate variability (HRV) during normoxia and hypoxia relative to individuals with typical P 50. Methods Nine humans with a HAH mutation (6 female, Age: 40±12yrs, P 50 : 16±1 mmHg) and 12 controls with typical affinity hemoglobin (6 female, Age: 40±10yrs, P 50 : 26±1 mmHg) laid supine for 10‐minutes prior to 20‐minutes of isocapnic hypoxia, titrated to reduce arterial O 2 pressure to ~50 mmHg (Avg. F i O 2 = 11.9±0.0%). Beat‐to‐beat arterial pressures (arterial catheter) and heart rate (electrocardiogram) were continuously recorded. Data were averaged in five‐minute segments starting with the last five minutes of supine normoxic rest. Spontaneous cBRS was quantified using the sequence method. HRV was measured in time and frequency domains. Standard deviation of the RR interval (SDRR) was calculated as the standard deviation of all RR intervals in a data segment. Low frequency (LF) HRV was calculated using Fast Fourier Transformation and assessed as absolute spectral intensity in the LF band (0.04‐0.15Hz). Results Arterial oxygen (P a O 2 ) and carbon dioxide (P a CO 2 ) pressures were not different between humans with HAH and controls during normoxia or isocapnic hypoxia [P a O 2 : (HAH vs. Control): 48±3 vs. 47±2 mmHg, p=0.612; P a CO 2 : (HAH vs. Control): 40±3 vs. 39±1 mmHg, p=0.328] exposure. cBRS was lower in humans with HAH compared to controls in normoxia and throughout isocapnic hypoxia [normoxia (HAH vs. Control): 7±4 vs. 16±10 ms/mmHg; hypoxia minutes 15‐20 (HAH vs. Control): 4±3 vs. 14±11 ms/mmHg; Hb type, p=0.024]. Several metrics of HRV were lower in humans with HAH relative to control (SDRR: Hb type, p≤0.001; LF: Hb type, p=0.030) and HRV was blunted to a similar extent in both groups with hypoxia (SDRR: time effect, p=0.009). Conclusion The findings of this study are twofold. Compared to controls, humans with HAH have: 1) attenuated cardiac baroreflex sensitivity and 2) lower heart rate variability in both normoxia and isocapnic hypoxia.
Central hemodynamic response during submaximal and exhaustive exercise in humans with high affinity hemoglobin and compensatory polycythemia
The FASEB Journal | May 3, 2022 | Volume: 36 | Issue: S1 | Pages: No page available
Humans with high affinity hemoglobin (HAH) develop compensatory polycythemia, an elevated hematocrit, which increases blood viscosity and may compromise cardiac output during exercise. In addition, humans with HAH have shown alterations in muscle blood flow during exercise in normoxia and hypoxia. As such, we aimed to investigate the influence of HAH and compensatory polycythemia on the central hemodynamic response during both normoxic and hypoxic exercise. METHODS Seven humans with HAH (4 females, 36 ± 13 years) and 11 healthy controls with normal oxygen binding affinity (4 females, 39 ± 10 years) performed cycling exercise at two intensities, 1) at a power output corresponding to 15% below normoxic gas exchange threshold (GET) for four minutes and 2) at a power output requiring 85% of normoxic maximal aerobic capacity until exhaustion. This protocol was performed during both normoxia and hypoxia (21% O 2 and 15% O 2 , respectively). Hemodynamic measurements were taken after three minutes of cycling at 15% below normoxic GET, three minutes at 85% V̇O 2max , and at exhaustion. Cardiac output (Q̇) was estimated using an open‐circuit acetylene wash‐in technique. Stroke volume (SV) was calculated by dividing Q̇ by heart rate (HR). Baseline characteristics were compared between groups with student’s two‐tailed unpaired t‐tests. Hemodynamics were analyzed using a two‐way repeated measures analysis of variance to examine the effects of group and exercise intensity. RESULTS As expected, hematocrit was ~15% greater in the HAH group than the control group (HAH: 58 ± 7 % vs CTL: 43 ± 3 %, P<0.001). Both groups elicited an increase in Q̇ and HR as exercise intensity increased during both normoxia (P<0.001 for both) and hypoxia (P<0.001 and P=0.002, respectively). There was no significant difference in Q̇ between groups during normoxia (P=0.85) or hypoxia (P=0.69). In addition, neither HR nor SV were different between groups during exercise in normoxia (P=0.13 and P=0.39, respectively) or hypoxia (P=0.89 and P=0.73, respectively). There was no group by intensity interaction for Q̇, HR, or SV during normoxia (all, P>0.42) or hypoxia (all, P>0.63). CONCLUSION Our data suggest that cardiac output is not compromised during normoxic or hypoxic exercise in humans with HAH and compensatory polycythemia. Therefore, compensatory polycythemia may improve exercise capacity in humans with HAH by raising oxygen carrying capacity without limiting cardiac output.
Convalescent plasma with a high level of virus-specific antibody effectively neutralizes SARS-CoV-2 variants of concern
Abstract The ongoing evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants severely limits available effective monoclonal antibody therapies. Effective drugs are also supply limited. COVID-19 convalescent plasma (CCP) qualified for high antibody levels effectively reduces immunocompetent outpatient hospitalization. The Food and Drug Administration currently allows outpatient CCP for the immunosuppressed. Viral-specific antibody levels in CCP can range 10- to 100-fold between donors, unlike the uniform viral-specific monoclonal antibody dosing. Limited data are available on the efficacy of polyclonal CCP to neutralize variants. We examined 108 pre-δ/pre-ο donor units obtained before March 2021, 20 post-δ COVID-19/postvaccination units, and 1 pre-δ/pre-ο hyperimmunoglobulin preparation for variant-specific virus (vaccine-related isolate [WA-1], δ, and ο) neutralization correlated to Euroimmun S1 immunoglobulin G antibody levels. We observed a two- to fourfold and 20- to 40-fold drop in virus neutralization from SARS-CoV-2 WA-1 to δ or ο, respectively. CCP antibody levels in the upper 10% of the 108 donations as well as 100% of the post-δ COVID-19/postvaccination units and the hyperimmunoglobulin effectively neutralized all 3 variants. High-titer CCP neutralizes SARS-CoV-2 variants despite no previous donor exposure to the variants.
AI-Enabled Advanced Development for Assessing Low Circulating Blood Volume for Emergency Medical Care: Comparison of Compensatory Reserve Machine-Learning Algorithms
The application of artificial intelligence (AI) has provided new capabilities to develop advanced medical monitoring sensors for detection of clinical conditions of low circulating blood volume such as hemorrhage. The purpose of this study was to compare for the first time the discriminative ability of two machine learning (ML) algorithms based on real-time feature analysis of arterial waveforms obtained from a non-invasive continuous blood pressure system (Finometer®) signal to predict the onset of decompensated shock: the compensatory reserve index (CRI) and the compensatory reserve metric (CRM). One hundred ninety-one healthy volunteers underwent progressive simulated hemorrhage using lower body negative pressure (LBNP). The least squares means and standard deviations for each measure were assessed by LBNP level and stratified by tolerance status (high vs. low tolerance to central hypovolemia). Generalized Linear Mixed Models were used to perform repeated measures logistic regression analysis by regressing the onset of decompensated shock on CRI and CRM. Sensitivity and specificity were assessed by calculation of receiver-operating characteristic (ROC) area under the curve (AUC) for CRI and CRM. Values for CRI and CRM were not distinguishable across levels of LBNP independent of LBNP tolerance classification, with CRM ROC AUC (0.9268) being statistically similar (p = 0.134) to CRI ROC AUC (0.9164). Both CRI and CRM ML algorithms displayed discriminative ability to predict decompensated shock to include individual subjects with varying levels of tolerance to central hypovolemia. Arterial waveform feature analysis provides a highly sensitive and specific monitoring approach for the detection of ongoing hemorrhage, particularly for those patients at greatest risk for early onset of decompensated shock and requirement for implementation of life-saving interventions.
Early administration of COVID‐19 convalescent plasma with high titer antibody content by live viral neutralization assay is associated with modest clinical efficacy
American Journal of Hematology | March 18, 2022 | Volume: 97 | Issue: 6 | Pages: 770-779
AbstractThe efficacy of COVID‐19 convalescent plasma (CCP) as a treatment for hospitalized patients with COVID‐19 remains somewhat controversial; however, many studies have not evaluated CCP documented to have high neutralizing antibody titer by a highly accurate assay. To evaluate the correlation of the administration of CCP with titer determined by a live viral neutralization assay with 7‐ and 28‐day death rates during hospitalization, a total of 23 118 patients receiving a single unit of CCP were stratified into two groups: those receiving high titer CCP (>250 50% inhibitory dilution, ID50; n = 13 636) or low titer CCP (≤250 ID50; n = 9482). Multivariable Cox regression was performed to assess risk factors. Non‐intubated patients who were transfused with high titer CCP showed 1.1% and 1.7% absolute reductions in overall 7‐ and 28‐day death rates, respectively, compared to those non‐intubated patients receiving low titer CCP. No benefit of CCP was observed in intubated patients. The relative benefit of high titer CCP was confirmed in multivariable Cox regression. Administration of CCP with high titer antibody content determined by live viral neutralization assay to non‐intubated patients is associated with modest clinical efficacy. Although shown to be only of modest clinical benefit, CCP may play a role in the future should viral variants develop that are not neutralized by other available therapeutics.
COVID-19 Convalescent Plasma and Clinical Trials: Understanding Conflicting Outcomes
Clinical Microbiology Reviews | March 9, 2022 | Volume: 35 | Issue: 3 | Pages: No page available
Convalescent plasma (CP) recurs as a frontline treatment in epidemics because it is available as soon as there are survivors. The COVID-19 pandemic represented the first large-scale opportunity to shed light on the mechanisms of action, safety, and efficacy of CP using modern evidence-based medicine approaches. Studies ranging from observational case series to randomized controlled trials (RCTs) have reported highly variable efficacy results for COVID-19 CP (CCP), resulting in uncertainty.