Three‐Dimensional Shear Wave Elastography for Differentiating Benign From Malignant Thyroid Nodules

Journal of Ultrasound in Medicine | January 10, 2018 | Volume: 37 | Issue: 7 | Pages: 1777-1788

10.1002/jum.14531 | PMID 29315789

ObjectivesTo prospectively evaluate the diagnostic performance of 3‐dimensional (3D) shear wave elastography (SWE) for assessing thyroid nodules.MethodsA total of 176 surgically or cytologically confirmed thyroid nodules (63 malignant and 113 benign) in 176 patients who had undergone conventional ultrasound (US), 2‐dimensional (2D) SWE, and 3D SWE examinations were included in this study. Quantitative elasticity values (mean elasticity, maximum elasticity, and standard deviation of elasticity of a large region of interest and mean elasticity of a 2‐mm region of interest) were measured on 2D and 3D SWE. Diagnostic performances of conventional US, 2D SWE, and 3D SWE were assessed. The role of 2D and 3D SWE in reducing unnecessary fine‐needle aspiration (FNA) for nodules with low suspicion was also evaluated.ResultsThe diagnostic performances in terms of the area under the receiver operating characteristic curve were 0.612 for conventional US, 0.836 for 2D SWE (P < .001 in comparison with conventional US), and 0.839 for 3D SWE (P < .001 in comparison with conventional US). The mean elasticity achieved the highest diagnostic performance in 2D SWE, whereas the standard deviation of elasticity achieved the highest performance in 3D SWE, although no significant difference was found between them (P > .05). Three‐dimensional SWE increased the specificity in comparison with 2D SWE (88.5% versus 82.3%; P = .039). For the 37 nodules with low suspicion on conventional US imaging, 2D SWE was able to avoid unnecessary FNA in 77.1% (27 of 35) of benign nodules, and 3D SWE further increased the number to 88.6% (31 of 35).ConclusionsThree‐dimensional SWE is a useful tool for predicting thyroid nodule malignancy and reducing unnecessary FNA procedures in thyroid nodules with low suspicion of malignancy.
Shear elasticity and shear viscosity imaging in viscoelastic phantoms

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3721

10.1121/1.4988148

Shear wave elasticity imaging determines the mechanical parameters of soft tissue by analyzing measured shear waves induced by an acoustic radiation force. Currently, the widely used time-of-flight method calculates the correlation between shear waveforms at adjacent lateral observation points to estimate the shear elasticity value. Although this method provides accurate estimates of the shear elasticity in purely elastic media, our experience suggests that this approach overestimates the shear elasticity values in viscoelastic media because the effects of diffraction, attenuation, and dispersion are not taken into account. To address this problem, we have developed an approach that directly accounts for all of these effects when estimating the shear elasticity. This new approach simulates shear waveforms using a Green’s function-based approach with a Voigt model, while the shear elasticity and viscosity values are estimated using an optimization-based approach by comparing measured shear waveforms with simulated shear waveforms in the time-domain. This operation is then performed on a point-by-point basis to generate images. The results indicate that there is good agreement between the simulated and measured shear velocity waveforms, and that this approach yields improved images of the shear elasticity and shear viscosity. [Work supported, in part, by NIH Grant R01DK092255.]
Shear wave phase velocity dispersion estimation in viscoelastic materials using the Multiple Signal Classification method

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3720-3720

10.1121/1.4988145

Shear wave elastography (SWE) is clinically used for the measurement of soft tissue mechanical properties. Most SWE methods assume that the tissue is elastic, but soft tissues are inherently viscoelastic. The viscoelasticity can be characterized by examining phase velocity dispersion. Methods to extract the phase velocities from the spatiotemporal data, v(x,t), involve using a two-dimensional Fourier transform. The Fourier representation, V(k,f), is searched for peaks that correspond to the phase velocities. We present a method that uses the Multiple Signal Classification (MUSIC) method to provide robust estimation of the phase velocity dispersion curves. We compared results from the MUSIC method with the current approach of searching for peaks in the V(k,f) representation. We tested this method on digital phantom data created using finite element models (FEMs) in viscoelastic media excited by a simulated acoustic radiation force push from a curved linear array. We evaluated the algorithm with different levels of added noise. Additionally, we tested the methods on data acquired in viscoelastic phantoms with a Verasonics system. The MUSIC algorithm provided dispersion estimation with lower errors than the conventional peak search strategy. This method can be used for evaluation of wave velocity dispersion in viscoelastic tissues and guided wave propagation. [This work was supported in part by grant R01DK092255.]
Attenuation measuring ultrasound shearwave elastography and in vivo application in post-transplant liver patients

Physics in Medicine & Biology | December 21, 2016 | Volume: 62 | Issue: 2 | Pages: 484-500

10.1088/1361-6560/aa4f6f | PMID 28000623

Abstract Ultrasound and magnetic resonance elastography techniques are used to assess mechanical properties of soft tissues. Tissue stiffness is related to various pathologies such as fibrosis, loss of compliance, and cancer. One way to perform elastography is measuring shear wave velocity of propagating waves in tissue induced by intrinsic motion or an external source of vibration, and relating the shear wave velocity to tissue elasticity. All tissues are inherently viscoelastic and ignoring viscosity biases the velocity-based estimates of elasticity and ignores a potentially important parameter of tissue health. We present attenuation measuring ultrasound shearwave elastography (AMUSE), a technique that independently measures both shear wave velocity and attenuation in tissue and therefore allows characterization of viscoelasticity without using a rheological model. The theoretical basis for AMUSE is first derived and validated in finite element simulations. AMUSE is validated against the traditional methods for assessing shear wave velocity (phase gradient) and attenuation (amplitude decay) in tissue mimicking phantoms and excised tissue. The results agreed within one standard deviation. AMUSE was used to measure shear wave velocity and attenuation in 15 transplanted livers in patients with potential acute rejection, and the results were compared with the biopsy findings in a preliminary study. The comparison showed excellent agreement and suggests that AMUSE can be used to separate transplanted livers with acute rejection from livers with no rejection.
Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren’s Syndrome: A Preliminary Study

BioMed Research International | December 18, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-6

10.1155/2016/2793898 | PMID 28078285

A total of 136 subjects (51 SS patients, 35 sicca syndrome patients without SS, and 50 healthy volunteers) were enrolled in this study. The mean SWV value for salivary glands of SS patients was statistically higher than that of controls (2.81 ± 0.66 m/s versus 1.85 ± 0.28 m/s for parotid glands and 2.29 ± 0.34 m/s versus 1.82 ± 0.25 m/s for submandibular glands, resp.). Combining SWV values of parotid and submandibular glands gives a sensitivity of 88.2% (95% CI: 76.1–95.6%) and specificity of 96.0% (95% CI: 86.3–99.5%) at the cutoff point of 2.19 m/s, with an AUROC of 0.954 (95% CI: 0.893–0.986). In addition, combining SGUS score and SWV value yields a sensitivity of 98.0% (95% CI: 89.6–100%), specificity of 90.0% (95% CI: 78.2–96.7%), and AUROC of 0.962 (95% CI: 0.904–0.990). Classification tree considering the sequential use of SGUS score and SWV value achieved 92.1% accuracy for diagnosis of SS. Similarly, the ROC curve of combined SGUS scores and SWV values yields an AUROC of 0.954 (95% CI: 0.885–0.987), sensitivity of 97.1% (95% CI: 85.1–99.9%), and specificity of 92.2% (95% CI: 81.1–97.8%) for separating sicca syndrome patients (without SS) from SS patients. Combining SGUS and VTQ provides a promising tool for diagnosis of SS.
Investigation of the effects of myocardial anisotropy for shear wave elastography using impulsive force and harmonic vibration

Physics in Medicine & Biology | December 16, 2015 | Volume: 61 | Issue: 1 | Pages: 365-382

10.1088/0031-9155/61/1/365 | PMID 26674613

Abstract The myocardium is known to be an anisotropic medium where the muscle fiber orientation changes through the thickness of the wall. Shear wave elastography methods use propagating waves which are measured by ultrasound or magnetic resonance imaging (MRI) techniques to characterize the mechanical properties of various tissues. Ultrasound- or MR-based methods have been used and the excitation frequency ranges for these various methods cover a large range from 24–500 Hz. Some of the ultrasound-based methods have been shown to be able to estimate the fiber direction. We constructed a model with layers of elastic, transversely isotropic materials that were oriented at different angles to simulate the heart wall in systole and diastole. We investigated the effect of frequency on the wave propagation and the estimation of fiber direction and wave speeds in the different layers of the assembled models. We found that waves propagating at low frequencies such as 30 or 50 Hz showed low sensitivity to the fiber direction but also had substantial bias in estimating the wave speeds in the layers. Using waves with higher frequency content (>200 Hz) allowed for more accurate fiber direction and wave speed estimation. These results have particular relevance for MR- and ultrasound-based elastography applications in the heart.
Characterization of material properties of soft solid thin layers with acoustic radiation force and wave propagation

The Journal of the Acoustical Society of America | October 28, 2015 | Volume: 138 | Issue: 4 | Pages: 2499-2507

10.1121/1.4932170 | PMID 26520332

Evaluation of tissue engineering constructs is performed by a series of different tests. In many cases it is important to match the mechanical properties of these constructs to those of native tissues. However, many mechanical testing methods are destructive in nature which increases cost for evaluation because of the need for additional samples reserved for these assessments. A wave propagation method is proposed for characterizing the shear elasticity of thin layers bounded by a rigid substrate and fluid-loading, similar to the configuration for many tissue engineering applications. An analytic wave propagation model was derived for this configuration and compared against finite element model simulations and numerical solutions from the software package Disperse. The results from the different models found very good agreement. Experiments were performed in tissue-mimicking gelatin phantoms with thicknesses of 1 and 4 mm and found that the wave propagation method could resolve the shear modulus with very good accuracy, no more than 4.10% error. This method could be used in tissue engineering applications to monitor tissue engineering construct maturation with a nondestructive wave propagation method to evaluate the shear modulus of a material.
Simulation of wave propagation in anisotropic and viscoelastic tissues

The Journal of the Acoustical Society of America | October 14, 2015 | Volume: 138 | Issue: 3_Supplement | Pages: 1906-1906

10.1121/1.4933994

Many methods for characterization of the mechanical properties of soft tissues using propagating shear waves have been developed over the past two decades. Most of these methods assume that the shear wave is traveling in an elastic, isotropic tissue. However, many soft tissues are viscoelastic and have material properties that are directionally dependent or anisotropic. We have been developing methods to measure waves propagating in soft tissues to estimate the anisotropic viscoelastic material properties. To refine our measurement methods, we have also developed techniques and models for simulating the wave propagation in these types of materials. We have developed specialized finite element and pseudo-spectral models that can simulate viscoelastic transversely isotropic materials and compared our results with measurements in ex vivo porcine muscle. Additionally, we have developed a finite element model that simulates wave propagation in the myocardium by creating a model of layered transverse isotropic media oriented at different angles. We examined the effect of frequency of the waves for estimating of the angle of propagation. We compared these simulation results with experimental results from an ex vivo porcine left ventricular wall. These simulation methods provide insight for optimizing our measurement methods for in vivo characterization of material properties.
Feasibility assessment of shear wave elastography to rotator cuff muscle

Clinical Anatomy | December 30, 2014 | Volume: 28 | Issue: 2 | Pages: 213-218

10.1002/ca.22498 | PMID 25557287

Pre‐surgical measurement of supraspinatus muscle extensibility is important for rotator cuff repair. The purpose of the present study was to explore the potential feasibility of a shear wave ultrasound elastography (SWE)‐based method, combined with B‐mode ultrasound, to measure the in vivo stiffness of the supraspinatus muscle non‐invasively and thus obtain key information about supraspinatus muscle extensibility. Our investigation comprised two steps. First, we determined the orientation of the supraspinatus muscle fibers in cadaveric shoulders without rotator cuff tear in order to optimize the ultrasound probe positions for SWE imaging. Second, we investigated the feasibility of quantifying the stiffness of the normal supraspinatus muscle by SWE in vivo. The supraspinatus muscle was divided into four anatomical regions: anterior superficial (AS), posterior superficial (PS), anterior deep (AD), and posterior deep (PD). Each region was examined by SWE. The SWE stiffnesses of AD, AS, PD, and PS were 40.0 ± 12.4, 34.0 ± 9.9, 32.7 ± 12.7, 39.1 ± 15.7 kPa, respectively. SWE combined with B‐Mode ultrasound imaging could be a feasible method for quantifying the local stiffness of the rotator cuff muscles. Clin. Anat. 28:213–218, 2015. © 2014 Wiley Periodicals, Inc.
Differentiation of benign and malignant breast lesions using Comb-Push Ultrasound Shear Elastography

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2159-2159

10.1121/1.4899813

In this work, the results from our Comb Push Ultrasound Shear Elastography (CUSE) assessment of suspicious breast lesions are presented. The elasticity value of the breast lesions are correlated to histopathological findings to evaluate their diagnostic value in differentiating between malignant and benign breast lesions. A total of 44 patients diagnosed with suspicious breast lesions were evaluated using CUSE prior to biopsy. All patient study procedures were conducted according to the protocol approved by Mayo Clinic Institutional Review Board (IRB). Our cohort consisted of 27 malignant and 17 benign breast lesions. The results indicate an increase in shear wave velocity in both benign and malignant lesions compared to normal breast tissue. Furthermore, the Young’s modulus is significantly higher in malignant lesions. An optimal cut-off value of the Young’s modulus ≥ 80 kPa was observed for the receiver operating characteristic (ROC) curve. This is concordant with the published cut-off values of elasticity for suspicious breast lesions. [This work is supported in part by the grant 3R01CA148994-04S1 and 5R01CA148994-04 from NIH.]