Citations 76

Real-time 3D ultrasound imaging with a clip-on device attached to common 1D array transducers

The Journal of the Acoustical Society of America | July 3, 2024 | Volume: 155 | Issue: 3_Supplement | Pages: A102-A102

10.1121/10.0026955

Performing 3D ultrasound imaging at a real-time volume rate (e.g., >20 Hz) is a challenging task. While 2D array transducers remain the most practical approach for real-time 3D imaging, the large number of transducer elements (e.g., several thousand) that are necessary to cover an effective 3D field-of-view impose a fundamental constraint on imaging speed. Although solutions such as multiplexing and specialized transducers, including sparse arrays and row-column-addressing arrays, have been developed to address this limitation, they inevitably compromise imaging quality (e.g., SNR, resolution) in favor of speed. Coupled with the high equipment cost of 2D arrays, these compromises hinder the widespread adoption of 3D ultrasound imaging technologies in clinical settings. In this presentation, we introduce an innovative transducer clip-on device comprising a water-immersible, fast-tilting electromechanical acoustic reflector and a redirecting reflector to enable real-time 3D ultrasound imaging using common 1D array transducers. We will first introduce the principles underlying our novel technique, followed by validation studies incorporating simulation and experimental data. We will also demonstrate the feasibility of using the clip-on device to achieve a high 3D imaging volume rate that is suitable for advanced imaging modes such as shear wave elastography, blood flow imaging, and super-resolution ultrasound localization microscopy.
Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | February 16, 2024 | Volume: 71 | Issue: 4 | Pages: 448-458

10.1109/tuffc.2024.3366540 | PMID 38363671

Enhancement of Ultrasound Microbubble and Blood Flow Imaging using Similarity Measurement

No container title available | December 3, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.36227/techrxiv.24635853.v1

Recent advancements in ultrasound technologies, such as ultrasound localization microscopy and ultrafast ultrasound Doppler, have enabled high-definition imaging of microvasculature. However, detecting weak microbubble or blood flow signals amid strong background noise remains a challenge, particularly in deep tissues. This study aims to enhance the signal contrast of microbubble and blood flow by leveraging their distinct spatial-temporal coherence in comparison to undesired noise for robust microbubble detection and microvascular imaging. We propose to quantify the signal coherence based on similarity analysis of beamformed ultrasound microbubble/blood flow data within the plane wave imaging framework. A spatial pixel is considered more likely to be a true microbubble/blood flow signal with a higher level of similarity, which can be measured by either of the following methods: 1) spatially block-wise normalized cross-correlation between two compounded frames; 2) temporally normalized autocorrelation across multiple compounded frames; 3) normalized cross-correlation between two subsets of post-compounded frames; 4) normalized autocorrelation of the pre-compounded data across angular direction. The original microbubble/blood flow signal is then weighted by the similarity measurement on a pixel-by-pixel basis to generate images with an improved signal contrast. The robustness of the proposed methods was first demonstrated in both phantom experiments and in vivo microbubble data from kidney transplant. We further validated their feasibility in blood flow imaging without the use of microbubbles based on in vivo data of human liver and kidney. Significant contrast improvement was observed, facilitating better visualization and detection of both microbubble and noncontrast microflow signals, which indicates a great potential of the methods for improved microvascular imaging and widespread clinical translation.
Ultrasound‐targeted microbubble destruction mediates PDE5i/NO integration for cavernosum remodeling and penile rehabilitation

Bioengineering & Translational Medicine | July 3, 2023 | Volume: 8 | Issue: 5 | Pages: No page available

10.1002/btm2.10568 | PMID 37693040

AbstractErectile dysfunction (ED) caused by cavernous nerve injury (CNI) is refractory to heal mainly ascribed to the adverse remodeling of the penis induced by ineffectual microvascular perfusion, fibrosis, and neurotrophins scarcity in cavernosum. Phosphodiesterase type V inhibitors (PDE5i) have been regarded as an alternative candidate drug for avoiding penile neuropathy. However, the therapeutic efficacy is severely limited due to poor accumulation under systemic medication and endogenous nitric oxide (NO) deficiency in cavernosum. Herein, an innovative liposomal microbubble (MB) loaded with both Sildenafil (one of PDE5i) and NO was designed. Ultrasound‐targeted MB destruction (UTMD)‐mediated efficient release and integration erectogenic agents into corpus cavernosum with high biosafety. On a bilateral CNI rat model, the multifunctional MB‐cooperated UTMD improved microvascular perfusion in penis, simultaneously, alleviated hypoxia and oxidative stress, indicating successful activation of NO–cyclic guanosine monophosphate pathway. Also, evaluation of the endothelial/muscular composition, intracavernosal pressure, and neural integrity in the penis proved that coordinated intervention reversed the abnormal structural remodeling and promoted the recovery of functional erection. Our work demonstrates that MB loading Sildenafil and NO combined with UTMD hold great promise to “awaken” the efficacy of PDE5i in neurogenic ED, which provided a superior option for ensuring penile rehabilitation.
High-Volume-Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | June 5, 2023 | Volume: 70 | Issue: 8 | Pages: 799-809

10.1109/tuffc.2023.3282949 | PMID 37276113

Robust Principal Component Analysis with Wavelet-Based Sparsity Promotion to Mitigate Reverberation Clutters for Ultrasound Attenuation Estimation

2022 IEEE International Ultrasonics Symposium (IUS) | December 1, 2022 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/ius54386.2022.9957606

Ultrasensitive US Microvessel Imaging of Hepatic Microcirculation in the Cirrhotic Rat Liver

Radiology | November 22, 2022 | Volume: 307 | Issue: 1 | Pages: No page available

10.1148/radiol.220739 | PMID 36413130

Three-Dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array

BME Frontiers | July 19, 2022 | Volume: 2022 | Issue: No issue available | Pages: No page available

10.34133/2022/9879632 | PMID 37850186

Objective . To develop a 3D shear wave elastography (SWE) technique using a 2D row column addressing (RCA) array, with either external vibration or acoustic radiation force (ARF) as the shear wave source. Impact Statement . The proposed method paves the way for clinical translation of 3D SWE based on the 2D RCA, providing a low-cost and high volume rate solution that is compatible with existing clinical systems. Introduction . SWE is an established ultrasound imaging modality that provides a direct and quantitative assessment of tissue stiffness, which is significant for a wide range of clinical applications including cancer and liver fibrosis. SWE requires high frame rate imaging for robust shear wave tracking. Due to the technical challenges associated with high volume rate imaging in 3D, current SWE techniques are typically confined to 2D. Advancing SWE from 2D to 3D is significant because of the heterogeneous nature of tissue, which demands 3D imaging for accurate and comprehensive evaluation. Methods . A 3D SWE method using a RCA array was developed with a volume rate up to 2000 Hz. The performance of the proposed method was systematically evaluated on tissue-mimicking elasticity phantoms and in an in vivo case study. Results . 3D shear wave motion induced by either external vibration or ARF was successfully detected with the proposed method. Robust 3D shear wave speed maps were reconstructed for phantoms and in vivo . Conclusion . The high volume rate 3D imaging provided by the 2D RCA array provides a robust and practical solution for 3D SWE with a clear pathway for future clinical translation.
Reverberation clutter signal suppression in ultrasound attenuation estimation using wavelet-based robust principal component analysis

Physics in Medicine & Biology | March 31, 2022 | Volume: 67 | Issue: 9 | Pages: 095018

10.1088/1361-6560/ac62fd | PMID 35358950

Abstract Objective . Ultrasound attenuation coefficient estimation (ACE) has diagnostic potential for clinical applications such as quantifying fat content in the liver. Previously, we have proposed a system-independent ACE technique based on spectral normalization of different frequencies, called the reference frequency method (RFM). This technique does not require a well-calibrated reference phantom for normalization. However, this method may be vulnerable to severe reverberation clutter introduced by the body wall. The clutter superimposed on liver echoes may bias the estimation. Approach . We proposed to use robust principal component analysis, combined with wavelet-based sparsity promotion, to suppress the severe reverberation clutters. The capability to mitigate the reverberation clutters was validated through phantom and in vivo studies. Main Results . In the phantom studies with added reverberation clutters, higher normalized cross-correlation and smaller mean absolute errors were attained as compared to RFM results without the proposed method, demonstrating the capability to reconstruct tissue signals from reverberations. In a pilot patient study, the correlation between ACE and proton density fat fraction (PDFF), a measurement of liver fat by MRI as a reference standard, was investigated. The proposed method showed an improvement of the correlation (coefficient of determination, R = 0.82) as compared with the counterpart without the proposed method ( R = 0.69). Significance : The proposed method showed the feasibility of suppressing the reverberation clutters, providing an important basis for the development of a robust ACE with large reverberation clutters.
Curvelet Transform-Based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy

IEEE Transactions on Medical Imaging | March 28, 2022 | Volume: 41 | Issue: 9 | Pages: 2385-2398

10.1109/tmi.2022.3162839 | PMID 35344488