Citations 48

Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch

Catheterization and Cardiovascular Interventions | October 27, 2016 | Volume: 89 | Issue: 2 | Pages: 306-314

10.1002/ccd.26783 | PMID 27785879

ObjectivesTo report our experience with intravascular and hybrid intra‐operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation.BackgroundVenous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery.MethodsA retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015.ResultsOverall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8–46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5–45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure‐related mortality. At follow‐up (median 2, range 0.02–10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re‐stenosis (mean Doppler gradient; 2–3 mmHg) occurred in two patients who have not required re‐intervention. Trivial baffle leak was noted in four patients. Baffle re‐intervention was only occurred in one patient. One patient with pre‐procedural Class IV symptoms died 3.5 months after stent implantation.ConclusionsThis study is the largest reported experience of intravascular and intra‐operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
Transcatheter valve implantation for right atrium‐to‐right ventricle conduit obstruction or regurgitation after modified Björk–fontan procedure

Catheterization and Cardiovascular Interventions | July 28, 2016 | Volume: 89 | Issue: 2 | Pages: 298-305

10.1002/ccd.26648 | PMID 27465501

BackgroundThe most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra‐anatomic graft, is obstruction or regurgitation of the RA–RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA–RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA–RV modified Fontan pathway.MethodsThrough a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra‐anatomic RA–RV conduit or valve.ResultsAll patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow‐up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed.ConclusionPercutaneous transcatheter valve deployment to treat a dysfunctional RA–RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.
Non‐infectious thrombosis of the melody® valve: A tale of two cities

Catheterization and Cardiovascular Interventions | July 20, 2016 | Volume: 88 | Issue: 4 | Pages: 600-604

10.1002/ccd.26339 | PMID 27436491

Bioprosthetic valve thrombosis is an uncommon complication. We report two young women with prior uncomplicated percutaneous pulmonary valve replacement (Melody®, Medtronic, Inc. Minneapolis, MN) who later developed symptomatic pulmonary emboli and pulmonary valve dysfunction without evidence of infection. Thrombophilia risk factors included oral contraceptive use and mild thrombophilia. Both experienced recovery of valve function following anticoagulation. Acute changes in Melody® valve function should prompt a thorough investigation for and treatment of potential thrombotic causes. © 2016 Wiley Periodicals, Inc.
Ebstein anomaly, left ventricular non‐compaction, and early onset heart failure associated with a de novo α‐tropomyosin gene mutation

American Journal of Medical Genetics Part A | May 13, 2016 | Volume: 170 | Issue: 8 | Pages: 2186-2190

10.1002/ajmg.a.37745 | PMID 27177193

Ebstein anomaly of the tricuspid valve (EA) can be associated with left ventricular non‐compaction (LVNC), a rare congenital cardiomyopathy. We report a 2 year‐old female with EA and severe tricuspid regurgitation, LVNC, pulmonary hypertension, and chronic biventricular systolic heart failure, who died during evaluation for cardiac transplantation. Gene panel testing revealed a heterozygous de novo missense mutation in TPM1, which encodes the cardiac sarcomeric thin filament protein α‐tropomyosin. The c.475G>A variant results in a p.Asp159Asn substitution, altering a highly conserved residue predicted to be damaging to protein structure and function. TPM1 is the second gene linked to EA with LVNC in humans, implicating overlap in the molecular basis of structural and myopathic heart disease. © 2016 Wiley Periodicals, Inc.
Long‐term follow‐up after PFO device closure

Catheterization and Cardiovascular Interventions | March 31, 2016 | Volume: 89 | Issue: 1 | Pages: 124-133

10.1002/ccd.26518 | PMID 27027873

ObjectivesTo describe medium‐ to long‐term follow‐up of patients undergoing device closure of patent foramen ovale (PFO) for stroke or transient ischemic attack (TIA).BackgroundTranscatheter device closure of PFO continues to be used for secondary prevention of cryptogenic stroke or TIA, but data are lacking regarding long‐term outcomes.MethodsWe reviewed the Mayo Clinic Rochester PFO database for patients who underwent device closure of PFO for secondary prevention of stroke/TIA from December 2001 to June 2012. Demographic, clinical, procedural, and follow‐up data were reviewed. Recurrence rate of stroke/TIA were calculated. Data were analyzed to identify risk factors of recurrent neurologic events.ResultsSeven hundred and thirty patients (mean age 53 years; 40% female) were included in our study. Most patients (72%) had cryptogenic stroke as their qualifying event for PFO closure. There were no procedure‐related deaths or strokes. The most commonly used device was the Amplatzer Septal Occluder (82%). Median follow‐up was 6 years. A 3.9% of patients had documented residual right‐to‐left shunting at last echocardiogram. Recurrent stroke and/or TIA were reported in 45 patients, (6.3% of patients with follow‐up data). Patients who experienced recurrent stroke/TIA were older and had a higher rate of diabetes and hypertension than those who did not. The presence of residual shunt did not correlate with risk of recurrent events.ConclusionsDevice closure of PFO can be performed safely with very good long‐term resolution of atrial shunting. Recurrent neurologic events after PFO closure may reflect additional comorbid risk factors unrelated to the potential for paradoxical embolism. © 2016 Wiley Periodicals, Inc.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 | PMID 26994123

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.
Techniques and Outcomes for the Treatment of Paravalvular Leak

Circulation: Cardiovascular Interventions | July 24, 2015 | Volume: 8 | Issue: 8 | Pages: No page available

10.1161/circinterventions.115.001945 | PMID 26206850

Transcatheter closure of postmyocardial infarction, iatrogenic, and postoperative ventricular septal defects: The Mayo Clinic experience

Catheterization and Cardiovascular Interventions | May 29, 2015 | Volume: 86 | Issue: 7 | Pages: 1264-1270

10.1002/ccd.25989 | PMID 26033272

Objectives To determine event‐free survival after transcatheter closure of ventricular septal defect (VSD), and to identify predictors of adverse events (AE) in post myocardial infarction VSD (post‐MI VSD) subgroup. Background There are limited data on mid‐term follow‐up after transcatheter VSD closure. Methods Retrospective review of 27 cases of transcatheter VSD closure (post‐MI = 18 and non‐ischemic = 9) performed from 1999 to 2013. We defined AE as death, device embolization, hemolysis requiring blood transfusion, heart block and reintervention. Results In the post‐MI VSD subgroup, mean age and follow‐up was 69 ± 11 and 7.3 ± 7 years, respectively. AE occurred in 8 (44%) patients (death‐3, device embolization‐1, hemolysis‐1, surgical VSD closure‐2, reintervention‐1). Event‐free survival was 56% at 1 month and 5 years, and all AE occurred in the periprocedural period. Cardiogenic shock (HR: 3.21, CI: 1.82–5.41, P = 0.002), and VSD closure in acute phase (HR: 2.14, CI: 1.12–4.31, P = 0.004) were independent predictors of AE. In the non‐ischemic VSD subgroup, mean age and follow‐up was 49 ± 15 and 8.7 ± 8 years, respectively. AE occurred in 3 (33%) patients (late death‐1, surgical VSD closure‐2). For the entire cohort, freedom from death was 89% and 85% at 1 month and 5 years, and event‐free survival was 70% and 61% at 1 month and 5 years. Conclusions Transcatheter closure of post‐MI VSD carries a moderate risk of periprocedural complications but low event rates afterwards. By comparison, device closure of non‐ischemic VSD has lower periprocedural morbidity but some patients continued to experience AE during follow‐up. © 2015 Wiley Periodicals, Inc.
Embolization of Veno-venous Collaterals after the Fontan Operation Is Associated with Decreased Survival

Congenital Heart Disease | May 23, 2015 | Volume: 10 | Issue: 5 | Pages: E230-E236

10.1111/chd.12276 | PMID 26010433

Transcatheter tricuspid valve‐in‐valve in patients with transvalvular device leads

Catheterization and Cardiovascular Interventions | May 6, 2015 | Volume: 87 | Issue: 4 | Pages: No page available

10.1002/ccd.25990 | PMID 25946058

ObjectiveTo describe the effects of percutaneously implanted valve‐in‐valve in the tricuspid position for patients with pre‐existing transvalvular device leads.MethodsIn this case series, we describe implantation of the Melody valve and SAPIEN XT valve within dysfunctional bioprosthetic tricuspid valves in three patients with transvalvular device leads.ResultsIn all cases, the valve was successfully deployed and device lead function remained unchanged. In 1/3 cases with 6‐month follow‐up, device lead parameters remain unchanged and transcatheter valve‐in‐valve function remains satisfactory.ConclusionsTranscatheter tricuspid valve‐in‐valve is feasible in patients with pre‐existing transvalvular devices leads. Further study is required to determine the long‐term clinical implications of this treatment approach. © 2015 Wiley Periodicals, Inc.