Context.— Serum tests used for the screening and diagnosis of monoclonal gammopathies include serum protein electrophoresis (SPE; agarose gel or capillary zone), immunofixation (IFE) and immunosubtraction capillary electrophoresis, serum free light chains, quantitative immunoglobulins, and heavy/light–chain combinations. Urine protein electrophoresis and urine IFE may also be used to identify Bence-Jones proteinuria. Objective.— To assess current laboratory practice for monoclonal gammopathy testing. Design.— In April 2016, a voluntary questionnaire was distributed to 923 laboratories participating in a protein electrophoresis proficiency testing survey. Results.— Seven hundred seventy-four laboratories from 38 countries and regions completed the questionnaire (83.9% response rate; 774 of 923). The majority of participants (68.6%; 520 of 758) used agarose gel electrophoresis as their SPE method, whereas 31.4% (238 of 758) used capillary zone electrophoresis. The most common test approaches used in screening were SPE with reflex to IFE/immunosubtraction capillary electrophoresis (39.3%; 299 of 760); SPE only (19.1%; 145 of 760); SPE and IFE or immunosubtraction capillary electrophoresis (13.9%; 106 of 760); and SPE with IFE, serum free light chain, and quantitative immunoglobulins (11.8%; 90 of 760). Only 39.8% (305 of 767) of laboratories offered panel testing for ordering convenience. Although SPE was used by most laboratories in diagnosing new cases of myeloma, when laboratories reported the primary test used to follow patients with monoclonal gammopathy, only 55.7% (403 of 724) chose SPE, with the next most common selections being IFE (18.9%; 137 of 724), serum free light chain (11.7%; 85 of 724), and immunosubtraction capillary electrophoresis (2.1%; 15 of 724). Conclusions.— Ordering and testing practices for the screening and diagnosis of monoclonal gammopathy vary widely across laboratories. Improving utilization management and report content, as well as recognition and development of laboratory-directed testing guidelines, may serve to enhance the clinical value of testing.
Myocardial Cobalt Levels Are Elevated in the Setting of Total Hip Arthroplasty
Journal of Bone and Joint Surgery | November 15, 2017 | Volume: 99 | Issue: 22 | Pages: e118
Background: Arthroplasty implants commonly contain elemental metal that may undergo wear-related release. Recently, cases of hip implant-associated myocardial injury have been reported. However, we are not aware of any previous study that has systematically measured myocardial metal levels or examined the relationship with total hip arthroplasty (THA). Methods: Archives of our institution were queried for autopsies of individuals who had undergone THA between 1990 and 2013. Myocardial tissue samples were analyzed for cobalt (Co) and chromium (Cr) levels with inductively coupled plasma mass spectroscopy. Seventy-five Co/Cr-on-polyethylene THA cases were included (mean age at time of death = 77.4 years; 49% women) as were 73 non-arthroplasty controls matched for age, sex, and history of hypertension and diabetes mellitus. Results: Significantly higher median myocardial concentrations of Co were observed in individuals with THA compared with controls (0.12 versus 0.06 μg/g, p < 0.0001). The median Co concentration was 69% higher in patients who had undergone THA revision (0.169 μg/g) than in those who underwent primary THA (0.100 μg/g; p = 0.004). In general, higher Co levels were observed in those with multiple replaced joints, although this finding only trended toward significance. Cardiomegaly, interstitial fibrosis, and decreased ejection fraction were observed more frequently in the postmortem samples of patients with implants than in those of controls (p = 0.0002, 0.044, and 0.0039, respectively). Conclusions: We believe this to be the first study to quantify metal levels in cardiac tissue in patients with and without joint replacement. The elevated Co levels, in concert with cardiomegaly and increased interstitial fibrosis found during autopsy, in the arthroplasty cohort are novel, important findings. Although Co levels were significantly elevated above those in controls, the majority were below those seen in clinical case reports of death from Co cardiotoxicity associated with metal-on-metal prostheses. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities
The detection and quantification of monoclonal‐proteins (M‐proteins) are necessary for the diagnosis and evaluation of response in plasma cell dyscrasias. Immunoglobulin enrichment‐coupled with matrix‐assisted laser desorption ionization time‐of‐flight mass‐spectrometry (MASS‐FIX) is a simple and inexpensive method to identify M‐proteins, but its clinical generalizability has not yet been elucidated. We compared MASS‐FIX to protein electrophoresis (PEL), serum/urine immunofixation‐electrophoresis (IFE), and quantitative serum free‐light chain (FLC) for the identification of M‐proteins in different clinical diagnoses. Paired serum and urine samples from 257 patients were tested. There were six patients for whom s‐IFE and FLC ratio were positive and serum MASS‐FIX was negative, but when serum and urine MASS‐FIX results were combined, only one patient with light chain‐MGUS was missed. Serum/urine‐MASS‐FIX detected M‐proteins in 18 patients with negative serum/urine‐PEL/IFE and serum‐FLC, 10 of whom had multiple myeloma or AL amyloidosis, who were mistakenly thought to have complete hematologic response by serum/urine‐PEL/IFE and serum‐FLC. Nearly half of the AL amyloidosis patients had atypical spectra, which may prove to be a clue to the diagnosis and pathogenesis of the disease. In conclusion, MASS‐FIX has a comparable sensitivity with PEL/IFE/FLC methods and can help inform the clinical diagnosis.
Erratum to: Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
Journal of the American Society for Mass Spectrometry | March 23, 2017 | Volume: 28 | Issue: 5 | Pages: 839-839
AbstractImmunoglobulin light chain (AL) amyloidosis is a fatal complication of B‐cell proliferation secondary to deposition of amyloid fibrils in various organs. Urinary exosomes (UEX) are the smallest of the microvesicles excreted in the urine. Previously, we found UEX of patients with AL amyloidosis contained immunoglobulin light chain (LC) oligomers that patients with multiple myeloma did not have. To further explore the role of the LC oligomers, UEX was isolated from an AL amyloidosis patient with progressive renal disease despite achieving a complete response. LC oligomers were identified. Mass spectrometry (MS) of the UEX and serum identified two monoclonal lambda LCs. Proteomics of the trypsin digested amyloid fragments in the kidney by laser microdissection and MS analysis identified a λ6 LC. The cDNA from plasma cell clone was from the IGLV‐ 6‐57 family and it matched the amino acid sequences of the amyloid peptides. The predicted mass of the peptide product of the cDNA matched the mass of one of the two LCs identified in the UEX and serum. UEX combined with MS were able to identify 2 monoclonal lambda LCs that current clinical methods could not. It also identified the amyloidogenic LC which holds potential for response assessment in the future.
Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
Journal of the American Society for Mass Spectrometry | February 28, 2017 | Volume: 28 | Issue: 5 | Pages: 827-838