Severe Pulmonary Vein Stenosis Resulting From Ablation for Atrial Fibrillation

Circulation | October 28, 2016 | Volume: 134 | Issue: 23 | Pages: 1812-1821

10.1161/circulationaha.116.021949 | PMID 27793993

Background: The frequency of pulmonary vein stenosis (PVS) after ablation for atrial fibrillation has decreased, but it remains a highly morbid condition. Although treatment strategies including pulmonary vein dilation and stenting have been described, the long-term impacts of these interventions are unknown. We evaluated the presentation of severe PVS, and examined the risk for restenosis after intervention using either balloon angioplasty (BA) alone or BA with stenting. Methods: This was a prospective, observational study of 124 patients with severe PVS evaluated between 2000 and 2014. Results: All 124 patients were identified as having severe PVS by computed tomography in 219 veins. One hundred two patients (82%) were symptomatic at diagnosis. The most common symptoms were dyspnea (67%), cough (45%), fatigue (45%), and decreased exercise tolerance (45%). Twenty-seven percent of patients experienced hemoptysis. Ninety-two veins were treated with BA, 86 were treated with stenting, and 41 veins were not treated. A 94% acute procedural success rate was observed and did not differ by initial management. Major procedural complications occurred in 4 of the 113 patients (3.5%) who underwent invasive assessment, and minor complications occurred in 15 patients (13.3%). Overall, 42% of veins developed restenosis including 27% of veins (n=23) treated with stenting and 57% of veins (n=52) treated with BA. The 3-year overall rate of restenosis was 37%, with 49% of BA-treated veins and 25% of stented veins developing restenosis (hazard ratio, 2.77; 95% confidence interval, 1.72–4.45; P <0.001). After adjustment for age, CHA2DS2-VASc score, hypertension, and the time period of the study, there was still a significant difference in the risk of restenosis for BA versus stenting (hazard ratio, 2.46; 95% confidence interval, 1.47–4.12; P <0.001). Conclusions: The diagnosis of PVS is challenging because of nonspecific symptoms and the need for dedicated pulmonary vein imaging. There is no difference in acute success by type of initial intervention; however, stenting significantly reduces the risk of subsequent pulmonary vein restenosis in comparison with BA.
Effect of Ventricular Arrhythmia Ablation in Patients With Heart Mate II Left Ventricular Assist Devices: An Evaluation of Ablation Therapy

Journal of Cardiovascular Electrophysiology | October 21, 2016 | Volume: 28 | Issue: 1 | Pages: 68-77

10.1111/jce.13114 | PMID 27766717

VT Ablation in LVAD RecipientsBackgroundPatients with advanced heart failure (HF) are predisposed to ventricular arrhythmias (VAs), particularly following implantation of a left ventricular assist device (LVAD). There is minimal evidence for appropriate management strategies.ObjectivesThis study aimed to compare the burden of VA and response to ablation performed either before or following LVAD implantation.MethodsWe created a retrospective cohort of patients who underwent both VA ablation and Heart Mate II (Thoratec, Pleasanton, CA, USA) LVAD implantation at Mayo Clinic (Rochester, MN, USA). Patients were stratified based on whether they underwent VA ablation before (pre‐LVAD) or after LVAD (post‐LVAD) implantation. Descriptive analyses assessed 6‐month arrhythmia burden in relation to LVAD implantation and VA ablation.ResultsA total of 9 patients underwent both LVAD implantation and VA ablation. There were 3 and 6 patients, respectively, in the pre‐LVAD and post‐LVAD cohorts. Among patients in the pre‐LVAD cohort, the median number of VAs tended to increase after ablation (9 vs. 72) and decreased after LVAD implantation (72 vs. 63). Similarly among patients in the post‐LVAD cohort, the median burden of VAs increased after LVAD implantation (1 vs. 22) and the median burden decreased after ablation (22 vs. 13). Two of 6 patients had substrate related to the LVAD inflow cannula site, while other substrate was not related directly to the cannula.ConclusionsIn patients with progressive HF and LVAD implantation, ablation is associated with reduced VA rates. In LVAD patients, most VAs arise from substrate unrelated to the inflow cannula site.
Acute Sinus Node Dysfunction after Atrial Ablation: Incidence, Risk Factors, and Management

Pacing and Clinical Electrophysiology | August 17, 2016 | Volume: 39 | Issue: 10 | Pages: 1116-1125

10.1111/pace.12934 | PMID 27530090

BackgroundMany patients with atrial fibrillation (AF) or atrial flutter (Aflutter) have concomitant sinus node dysfunction (SND). Ablation may result in injury to the sinus node complex or its blood supply resulting in sinus arrest and need for temporary pacing. We sought to characterize patients who develop acute SND (ASND) during/immediately after AF/Aflutter ablation.MethodsWe performed a retrospective analysis of AF/Aflutter ablation patients between January 1, 2010 and February 28, 2015 to characterize those who required temporary pacemaker (TPM) implantation due to ASND (sinus arrest, sinus bradycardia <40 beats/min, or junctional rhythm with hemodynamic compromise) following atrial ablation.ResultsOf 2,151 patients, eight patients (<0.5%) with ASND manifesting as sinus arrest (n = 2), severe sinus bradycardia (n = 2), and junctional rhythm with hemodynamic compromise (n = 4) were identified (all male, age 66 ± 9.9 years, 4/8 [50%] persistent AF). AF ablation was performed in four, atypical Aflutter in one, and AF/Aflutter in three patients. The ablation set consisted of: pulmonary vein (PV) isolation (n = 6), roof line ablation (n = 6), mitral annulus‐left inferior PV line ablation (n = 5), left atrial appendage‐mitral annulus ablation (n = 1), cavotricuspid isthmus ablation (n = 5), and isolation or ablation near the superior vena cava (SVC, n = 4). Patients with peri‐SVC ablation were more likely to develop ASND (P = 0.03). All patients received TPM; six received permanent pacemaker before discharge, performed 3.5 days postablation (range 2–6 days). At 3‐month device interrogation, all patients were atrially paced >50%.ConclusionASND is a rare complication of atrial ablation. It may be more common when peri‐SVC ablation is performed and may necessitate permanent pacemaker implantation.
Catheter Ablation for Atrial Arrhythmias in Patients With Cardiac Amyloidosis

Journal of Cardiovascular Electrophysiology | July 16, 2016 | Volume: 27 | Issue: 10 | Pages: 1167-1173

10.1111/jce.13046 | PMID 27422772

Catheter Ablation for Atrial Arrhythmias in Patients With CABackgroundCardiac amyloidosis (CA) is associated with increased atrial arrhythmias risk. The efficacy/safety of catheter‐based ablation therapy in patients with CA has not been adequately assessed.Methods and ResultsAll diagnosed CA patients who underwent atrial arrhythmia ablation therapy from 1995 to 2015 were reviewed. Arrhythmia recurrence, NYHA symptoms, and mortality were recorded. A total of 26 patients with CA and atrial arrhythmias were included; there were 7 light‐chain (AL), 17 wild‐type transthyretin (ATTRwt), and 2 mutated transthyretin (ATTRm) amyloidosis patients in total. Of which 13 underwent atrial arrhythmia ablation (CA‐A) and 13 underwent AV nodal ablation (CA‐AVN). In the CA‐A group, there were: 3 with atrial fibrillation (AF); 6 with atrial flutter (AFL); 2 with AF/AFL; and 2 with atrial tachycardia (AT). One‐year and 3‐year recurrence‐free survival were 75% and 60%, respectively. NYHA symptom improvement 6 months postablation was observed in both CA‐A and CA‐AVN groups: 7/10 (70%) and 4/8 (50%), respectively. Eleven patients with CA died (8 in CA‐AVN group vs. 3 in CA‐A group).ConclusionsCatheter‐based ablation for patients with CA appears to provide important symptomatic relief. However, mortality from the underlying disease remains a significant issue for the amyloid light‐chain subtype.
Effect of Left Atrial Ablation Process and Strategy on Microemboli Formation During Irrigated Radiofrequency Catheter Ablation in an In Vivo Model

Circulation: Arrhythmia and Electrophysiology | January 14, 2016 | Volume: 9 | Issue: 1 | Pages: No page available

10.1161/circep.115.003226 | PMID 26763224

Background— Formation of microemboli during catheter ablation has been suggested as a cause for asymptomatic cerebral emboli. However, it is unknown which part of the process and ablation setting/strategy is most strongly related to this occurrence. Methods and Results— A total of 27 pigs were used. Catheter/sheath manipulations in left atrium were performed in 25 of 27 pigs outfitted with microemboli monitoring systems. Ablations using open-irrigated radiofrequency catheters were performed in 18 of 25 pigs. Two of 27 pigs did not undergo left atrial procedures and were injected with microembolic materials in the carotid artery to serve as positive controls. In total, 334 sheath/catheter manipulations (transseptal puncture, sheath flushing, catheter insertion, pulmonary vein venography, and sheath exchange) and 333 radiofrequency applications (power setting, 30/50 W; point-by-point/drag ablations) were analyzed. High microbubble volume in the extracorporeal circulation loop and a high number of microembolic signals in carotid artery were observed during sheath/catheter manipulations especially in saline/contrast injections at fast speed and ablations with steam pop. Fast sheath flushing produced significantly higher microbubble volume than slow sheath flushing (median, 12 200 versus 121 nL; P <0.0001). A total of 44 of 126 (35%) blood filters in the circulation loop showed microparticles (thrombus/coagulum and tissue). Most of them were seen after radiofrequency application especially in 50-W ablations, drag ablations, and steam pop. Brain magnetic resonance imaging showed positive-embolic lesions in control pigs. Conclusions— Formation of microbubbles was the greatest during fast saline/contrast injections and steam pops, whereas high-power radiofrequency applications, drag ablations, and steam pops produced most of the microparticles.
Treatment Planning Studies in Patient Data With Scanned Carbon Ion Beams for Catheter‐Free Ablation of Atrial Fibrillation

Journal of Cardiovascular Electrophysiology | December 8, 2015 | Volume: 27 | Issue: 3 | Pages: 335-344

10.1111/jce.12888 | PMID 26638826

Noninvasive AF Ablation With Carbon IonsIntroductionCatheter ablation with isolation of the pulmonary veins is a common treatment option for atrial fibrillation but still has insufficient success rates and carries several interventional risks. These treatment planning studies assessed if high‐dose single fraction treatment with scanned carbon ions (12C) can be reliably delivered for AF ablation, while sparing risk structures and considering respiratory and contractile target motion.Methods and ResultsTime resolved CT scans of complete respiratory and cardiac cycles of 9 and 5 patients, respectively, were obtained. Ablation lesions and organs at risk for beam delivery were contoured. Single fraction intensity‐modulated particle therapy with target doses of 25 and 40 Gy were studied and motion influences on these deliveries mitigated. Respiration had a large influence on lesion displacement (≤ 2 cm). End expiration could be exploited as a stable gating window. Smaller, but less predictable, heartbeat displacements (< 6 mm) remained to be mitigated because cardiac contraction resulted in insufficient dose coverage (V95 < 90 %) if uncompensated. Repeated irradiation (12C beam rescanning) during breath hold was used to accommodate contractile motion, resulting in good dose coverage. Dose depositions to all organs at risk were carefully examined and did not exceed values for X‐ray cancer treatment.ConclusionTreatment planning of 12C with delivery of physical ionizing radiation doses that have been described to induce complete block is feasible for AF ablation, considering human anatomy, dose constraints, and encasing underlying motion patterns from respiration and cardiac contraction at the LA–PV junction into treatment planning.
Patterns of Anticoagulation Use and Cardioembolic Risk After Catheter Ablation for Atrial Fibrillation

Journal of the American Heart Association | November 6, 2015 | Volume: 4 | Issue: 11 | Pages: No page available

10.1161/jaha.115.002597 | PMID 26541393

Background There is significant practice variation in oral anticoagulation ( OAC ) use following catheter ablation for atrial fibrillation. It is not clear whether the risk of cardioembolism increases after discontinuation of OAC following catheter ablation. Methods and Results We identified 6886 patients within a large national administrative claims database who underwent catheter ablation for atrial fibrillation between January 1, 2005, and September 30, 2014. We assessed the effect of time off of OAC by CHA 2 DS 2 ‐ VAS c score (after adjusting for other comorbidities) on risk of cardioembolism, using Cox proportional hazards models. There was an increase in the use of non–vitamin K OAC after ablation from 0% in 2005 to 69.8% in 2014. OAC discontinuation was high, with only 60.5% and 31.3% of patients remaining on OAC at 3 and 12 months, respectively. The rate of discontinuation was higher in low‐risk patients (82% versus 62.5% at 12 months for CHA 2 DS 2 ‐ VAS c 0–1 versus ≥2, respectively; P <0.001). Stroke occurred in 1.4% of patients with CHA 2 DS 2 ‐ VAS c ≥2 and 0.3% of those with CHA 2 DS 2 ‐ VAS c 0 or 1 over the study follow‐up. The risk of cardioembolism in the first 3 months after ablation was increased among those with any time off OAC (hazard ratio 8.06 [95% CI 1.53–42.3], P <0.05). The risk of cardioembolism beyond 3 months was increased with OAC discontinuation among high‐risk patients (hazard ratio 2.48 [95% CI 1.11–5.52], P <0.05) but not low‐risk patients. Conclusion The overall risk of stroke in postablation patients is low; however, OAC discontinuation after ablation is common and is associated with increased risk of cardioembolism for all patients within the first 3 months and for high‐risk patients in the long term. Continuing OAC for at least 3 months in all patients and indefinitely in high‐risk patients appears to be the safest strategy.
Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters

Journal of Cardiovascular Electrophysiology | September 11, 2015 | Volume: 27 | Issue: 1 | Pages: 102-109

10.1111/jce.12835 | PMID 26359632

Flex Tip Comparative AblationIntroductionNext‐generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety.MethodsEndocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain.ResultsAverage lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P‐value = 0.013) despite equal mean power and radiofrequency time. High‐temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High‐temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size.ConclusionsThe FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.
Impact of Freezing Time and Balloon Size on the Thermodynamics and Isolation Efficacy During Pulmonary Vein Isolation Using the Second Generation Cryoballoon

Circulation: Arrhythmia and Electrophysiology | June 17, 2015 | Volume: 8 | Issue: 4 | Pages: 836-845

10.1161/circep.115.002725 | PMID 26082516

Background— The differences in ablation characteristics of freezing time and balloon size using second generation cryoballoon are still unknown. Methods and Results— Twenty-six dogs underwent pulmonary vein (PV) isolation. Balloon and tissue temperatures (left atrial–PV junction, phrenic nerve, and internal esophagus) were monitored. The ablation duration was randomized to either 3 or 4 minutes, which did not show significant differences in temperature profiles, PV isolation success rate, complications, or histological changes. Twenty dogs underwent cryoablation using 28-mm cryoballoon, 6 dogs were done using the 23-mm cryoballoon. Positioning of the 23-mm cryoballoon was more distal in the PV, which resulted in better PV occlusion. Temperature profiles showed lower temperatures in the 23-mm cryoballoon than in the 28-mm cryoballoon (inner balloon, median [range]: −51.5 [−66.0 to −31.0] versus −43.0 [−64.0 to −26.0]°C, P <0.001; balloon surface: −43.0 [−60.0 to −15.8] versus −6.5 [−46.2 to 28.9]°C, P <0.001; left atrial–PV junction: −6.7 [−20.0 to 21.4] versus 15.8 [−14.4 to 35.1]°C, P <0.001), and trended toward a higher PV isolation success rate in the 23-mm cryoballoon. Histologically, deeper extensions of ablative lesions into the PV were seen with 23-mm cryoballoon, and larger ablative lesions were seen in the left atrial antrum using 28-mm cryoballoon. Conclusions— The efficacy of 3-minute ablation was not significantly different from 4-minute ablation in dogs. The 23-mm cryoballoon had a greater cooling effect than the 28-mm cryoballoon for small PVs, but showed narrower ablative lesions in the left atrial antrum.
Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy

Circulation: Arrhythmia and Electrophysiology | January 22, 2015 | Volume: 8 | Issue: 2 | Pages: 429-438

10.1161/circep.114.002436 | PMID 25609687

Background— Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results— Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions— This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.