Citations 34

Vibro-Acoustography: Quantification of Flow with Highly-Localized Low-Frequency Acoustic Force

Ultrasonic Imaging | March 2, 2013 | Volume: 23 | Issue: 4 | Pages: 249-256

10.1177/016173460102300403 | PMID 12051277

The intersection of two ultrasound beams with slightly different frequencies results in generation of a localized radiation force and stimulates emission of audio signals from targeted objects. Vibro-acoustography uses this phenomenon to probe elastic properties of objects. Vibro-acoustography of contrast microbubbles in degassed water produced quantitative flow measurements from analysis of their acoustic emission. We used a dual-beam transducer generating bursts of 40-kHz vibrations. The vibrations resulted from interference of 3.48-MHz and 3.52-MHz confocal beams intersecting at the center of a thin plastic conduit. We tested flows of 13, 48, 85, and 120 mL/min of contrast microbubbles at concentrations from 1.2 times 10 5 to 6 times 10 5 bubbles/mL. The amplitude of the acoustic emission was linear with microbubble concentrations up to a value of 3.6 times 10 5 bubbles/mL. A replenishment method for microbubble contrast and flow rate analysis was used with radiation force bursts deployed at 0.05, 0.1, 0.2, 0.5, 1, and 2-second pulsing intervals. The relation between the pulsing intervals and the peak amplitude was fitted by an exponential curve and a rate constant calculated for each tested flow rate. The rate constant values were linearly correlated with the tested flows. The vibro-acoustography method provides objective, quantitative, and highly-localized assessment of flow using contrast microbubbles.
Weighted Least-Squares Finite Element Method for Cardiac Blood Flow Simulation with Echocardiographic Data

Computational and Mathematical Methods in Medicine | January 16, 2012 | Volume: 2012 | Issue: No issue available | Pages: 1-9

10.1155/2012/371315 | PMID 22312412

As both fluid flow measurement techniques and computer simulation methods continue to improve, there is a growing need for numerical simulation approaches that can assimilate experimental data into the simulation in a flexible and mathematically consistent manner. The problem of interest here is the simulation of blood flow in the left ventricle with the assimilation of experimental data provided by ultrasound imaging of microbubbles in the blood. The weighted least-squares finite element method is used because it allows data to be assimilated in a very flexible manner so that accurate measurements are more closely matched with the numerical solution than less accurate data. This approach is applied to two different test problems: a flexible flap that is displaced by a jet of fluid and blood flow in the porcine left ventricle. By adjusting how closely the simulation matches the experimental data, one can observe potential inaccuracies in the model because the simulation without experimental data differs significantly from the simulation with the data. Additionally, the assimilation of experimental data can help the simulation capture certain small effects that are present in the experiment, but not modeled directly in the simulation.
Transcranial Doppler ultrasound blood flow velocity and pulsatility index as systemic indicators for Alzheimer's disease

Alzheimer's & Dementia | March 16, 2011 | Volume: 7 | Issue: 4 | Pages: 445-455

10.1016/j.jalz.2010.09.002 | PMID 21388892

BackgroundMultiple lines of evidence suggest that cardiovascular co‐morbidities hasten the onset of Alzheimer's disease (AD) or accelerate its course.MethodsTo evaluate the utility of cerebral vascular physical function and/or condition parameters as potential systemic indicators of AD, transcranial Doppler (TCD) ultrasound was used to assess cerebral blood flow and vascular resistance of the 16 arterial segments comprising the circle of Willis and its major tributaries.ResultsOur study showed that decreased arterial mean flow velocity and increased pulsatility index are associated with a clinical diagnosis of presumptive AD. Cerebral blood flow impairment shown by these parameters reflects the global hemodynamic and structural consequences of a multifaceted disease process yielding diffuse congestive microvascular pathology, increased arterial rigidity, and decreased arterial compliance, combined with putative age‐associated cardiovascular output declines.ConclusionsTCD evaluation offers direct physical confirmation of brain perfusion impairment and might ultimately provide a convenient and a noninvasive means to assess the efficacy of medical interventions on cerebral blood flow or reveal incipient AD. In the near term, TCD‐based direct assessments of brain perfusion might offer the prospect of preventing or mitigating AD simply by revealing patients who would benefit from interventions to improve circulatory system function.
Intracranial atherosclerosis as a contributing factor to Alzheimer's disease dementia

Alzheimer's & Dementia | March 16, 2011 | Volume: 7 | Issue: 4 | Pages: 436-444

10.1016/j.jalz.2010.08.228 | PMID 21388893

BackgroundA substantial body of evidence collected from epidemiologic, correlative, and experimental studies strongly associates atherosclerotic vascular disease (AVD) with Alzheimer's disease (AD). Depending on the precise interrelationship between AVD and AD, systematic application of interventions used to maintain vascular health and function as a component of standard AD therapy offers the prospect of mitigating the presently inexorable course of dementia. To assess this hypothesis, it is vital to rigorously establish the measures of AVD that are most strongly associated with an AD diagnosis.MethodsA precise neuropathological diagnosis was established for all subjects, using a battery of genetic, clinical, and histological methods. The severity of atherosclerosis in the circle of Willis was quantified by direct digitized measurement of arterial occlusion in postmortem specimens and was compared between AD and nondemented control groups by calculating a corresponding index of occlusion.ResultsAtherosclerotic occlusion of the circle of Willis arteries was more extensive in the AD group than in the nondemented control group. Statistically significant differences were also observed between control and AD groups with regard to Braak stage, total plaque score, total neurofibrillary tangle score, total white matter rarefaction score, brain weight, Mini‐Mental State Examination scores, and apolipoprotein E allelic frequencies.ConclusionsOur results, combined with a consideration of the multifaceted effects of impaired cerebral circulation, suggest an immediate need for prospective clinical trials to assess the efficacy of AD prevention using antiatherosclerotic agents.
P2‐107: Intracranial Atherosclerosis as a contributing factor to Alzheimer's disease Dementia

Alzheimer's & Dementia | June 25, 2009 | Volume: 5 | Issue: 4S_Part_10 | Pages: No page available

10.1016/j.jalz.2009.04.418

P2‐106: Echocardiography vortex formation time reveal cardiac diastolic transmitral flow dysfunction in Alzheimer's disease patients

Alzheimer's & Dementia | June 25, 2009 | Volume: 5 | Issue: 4S_Part_10 | Pages: No page available

10.1016/j.jalz.2009.04.417

Letter by Sengupta et al Regarding Article, “Mechanisms of Preejection and Postejection Velocity Spikes in Left Ventricular Myocardium: Interaction Between Wall Deformation and Valve Events”

Circulation | February 16, 2009 | Volume: 119 | Issue: 6 | Pages: No page available

10.1161/circulationaha.108.811182 | PMID 19221225

Carbohydrate Dependent Targeting of Cancer Cells by Bleomycin−Microbubble Conjugates

Journal of the American Chemical Society | February 2, 2009 | Volume: 131 | Issue: 7 | Pages: 2438-2439

10.1021/ja8091104 | PMID 19187019

Arterioventricular Coupling and Ventricular Efficiency After Antihypertensive Therapy

Hypertension | December 25, 2007 | Volume: 51 | Issue: 2 | Pages: 275-281

10.1161/hypertensionaha.107.097964 | PMID 18158354

Patients with hypertension exhibit impaired energetic coupling between the ventricle and the arterial system, leading to reduced cardiac mechanic efficiency and exercise capacity. We tested whether blood pressure normalization with current antihypertensive therapy can improve arterioventricular coupling. Eighteen hypertensive patients without other cardiovascular disease were examined before and after antihypertensive therapy. Transthoracic echocardiography was performed. Central aortic pressure waveforms, including end-systolic pressure, were derived from radial artery applanation tonometry. Afterload was increased with isometric handgrip exercise. Central aortic end-systolic pressure and ventricular volumes at rest and handgrip were used to calculate ventricular elastance, effective arterial elastance, arterioventricular coupling (effective arterial elastance/ventricular elastance), and mechanical efficiency. After 142±67 days, systolic blood pressure decreased from 150.9±14.6 to 119.8±9.2 mm Hg ( P <0.00001), diastolic blood pressure from 85.9±14.8 to 68.8±8.4 mm Hg ( P =0.00002), and cardiac output from 5.8±1.7 to 4.9±1.8 L/min ( P =0.03). Resting left ventricular end-systolic volume, ejection fraction, and septal thickness did not change. Ventricular elastance increased from 1.7±1.0 to 3.2±1.4 mm Hg/mL ( P =0.00002), whereas effective arterial elastance decreased from 1.4±0.5 to 1.2±0.4 mm Hg/mL ( P =0.02). Effective arterial elastance/ventricular elastance decreased in all patients, from 1.1±0.8 to 0.4±0.2 ( P =0.0002). Efficiency improved at rest (72.9±5.8% versus 83.5±5.7%; P <0.00001) and during handgrip (63.5±7.8% versus 78.9±7.1%; P <0.00001). In hypertensive patients, optimal brachial and central blood pressure reduction shifts arterioventricular coupling from cardiac output maximization to ventricular mechanical efficiency optimization. This occurs before significant changes in ventricular geometry and may be responsible for early clinical improvements.
Rapid Three-Dimensional Echocardiography

Circulation | September 28, 2007 | Volume: 103 | Issue: 24 | Pages: 2882-2884

10.1161/hc2401.092234 | PMID 11413074

Background —Clinical applicability of conventional ultrasonographic systems using mechanical adapters for 3D echocardiographic imaging has been limited by long acquisition and processing times. We developed a rapid (6-s) acquisition technique that collects apical tomograms using a continuously internally rotating transthoracic transducer. This study was performed to examine the clinical feasibility of rapid-acquisition 3D echocardiography to estimate left ventricular end-diastolic and end-systolic volumes using electron-beam computed tomography as the reference standard. Methods and Results —We collected a series of 6 to 11 apical echocardiographic tomograms, depending on heart rate, in 11 patients. There was good correlation, low variability, and low bias between rapid 3D echocardiography and electron-beam computed tomography for measuring left ventricular end-diastolic volume ( r =0.96; standard error of the estimate, 21.34 mL; bias, −4.93 mL) and left ventricular end-systolic volume ( r =0.96; standard error of the estimate, 14.78 mL; bias, −6.97 mL). Conclusions —The rapid-acquisition 3D echocardiography extends the use of a multiplane, internally rotating handheld transducer so that it becomes a precise and clinically feasible tool for assessing left ventricular volumes and function. A rapid-image acquisition time of 6 s would allow repeated image collection during the course of a clinical echocardiographic examination. Additional work must address rapid and automated data processing.