Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT

American Journal of Physiology-Heart and Circulatory Physiology | December 22, 2017 | Volume: 275 | Issue: 3 | Pages: H1103-H1114

10.1152/ajpheart.1998.275.3.h1103 | PMID 9724319

A microcomputed tomography (micro-CT) scanner, which generates three-dimensional (3-D) images consisting of up to a billion cubic voxels, each 5–25 μm on a side, and which has isotropic spatial resolution, is described. Its main components are a spectroscopic X-ray source that produces selectable primary emission peaks at ∼9, 18, or 25 keV and a fluorescing thin crystal plate that is imaged (at selectable magnification) with a lens onto a 2.5 × 2.5-cm, 1,024 × 1,024-pixel, charge-coupled device (CCD) detector array. The specimen is positioned close to the crystal and is rotated in 721 equiangular steps around 360° between each X-ray exposure and its CCD recording. Tomographic reconstruction algorithms, applied to these recorded images, are used to generate 3-D images of the specimen. The system is used to scan isolated, intact, fixed rodent organs (e.g., heart or kidney) with the image contrast of vessel lumens enhanced with contrast medium. 3-D image display and analysis are used to address physiological questions about the internal structure-to-function relationships of the organs.
Volume quantification of chest wall motion in dogs

Journal of Applied Physiology | December 21, 2017 | Volume: 65 | Issue: 5 | Pages: 2213-2220

10.1152/jappl.1988.65.5.2213 | PMID 3209565

We employed high-speed multisliced X-ray-computed tomography to determine the relative volume contributions of rib cage (delta Vrc) and diaphragmatic motion (delta Vdi) to tidal volume (VT) during spontaneous breathing in 6 anesthetized dogs lying supine. Mean values were 40 +/- 6% (SE) for delta Vrc and 62 +/- 8% of VT for delta Vdi. The difference between VT and changes in thoracic cavity volume was taken to represent a change in thoracic blood volume (2 +/- 3% of VT). To estimate how much of delta Vrc was caused by diaphragmatic contraction and how much of delta Vdi was caused by rib cage motion, delta Vrc and delta Vdi were determined during bilateral stimulation of the C5-C6 phrenic nerve roots in the apneic dog and again during spontaneous breathing after phrenicotomy. Thoracic cavity volume (Vth) measured during hypocapnic apnea was consistently larger than Vth at end expiration, suggesting that relaxation of expiratory muscles contributed significantly to both delta Vrc and delta Vdi during spontaneous inspiration. Phrenic nerve stimulation did not contribute to delta Vrc, suggesting that diaphragmatic contraction had no net expanding action on the rib cage above the zone of apposition. Spontaneous breathing after phrenicotomy resulted in small and inconsistent diaphragmatic displacement (8 +/- 4% of VT). We conclude that the diaphragm does not drive the rib cage to inflate the lungs and that rib cage motion does not significantly affect diaphragmatic position during spontaneous breathing in anesthetized dogs lying supine.
Chest wall motion during spontaneous breathing and mechanical ventilation in dogs

Journal of Applied Physiology | December 21, 2017 | Volume: 66 | Issue: 3 | Pages: 1179-1189

10.1152/jappl.1989.66.3.1179 | PMID 2708243

We measured the volume change of the thoracic cavity (delta Vth) and the volumes displaced by the diaphragm (delta Vdi) and rib cage (delta Vrc) in six pentobarbital-anesthetized dogs lying supine. A high-speed X-ray scanner (dynamic spatial reconstructor) provided three-dimensional images of the thorax during spontaneous breathing and during mechanical ventilation with paralysis. Tidal volume (VT) was measured by integrating gas flow. Changes in thoracic liquid volume (delta Vliq, presumably caused by changes in thoracic blood volume) were calculated as delta Vth - VT. Absolute volume displaced by the rib cage was not significantly different during the two modes of ventilation. During spontaneous breathing, thoracic blood volume increased during inspiration; delta Vliq was 12.3 +/- 4.1% of delta Vth. During mechanical ventilation, delta Vliq was nearly zero. Configuration of the relaxed chest wall was similar during muscular relaxation induced by either pharmacological paralysis or hyperventilation. Expiratory muscle activity produced 50 +/- 11% of the delta Vth during spontaneous breathing. We conclude that at constant VT the volume displaced by the rib cage is remarkably similar during the transition from spontaneous breathing to mechanical ventilation, while both diaphragmatic volume displacement and changes in intrathoracic blood volume decrease by a similar amount.
Measuring arterial wall perfusion using photon-counting computed tomography (CT): improving CT number accuracy of artery wall using image deconvolution

Journal of Medical Imaging | December 8, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.044006 | PMID 29250564

Detection of increased vasa vasorum in artery walls: improving CT number accuracy using image deconvolution

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323O

10.1117/12.2255676 | PMID 28413240

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 | PMID 28042589

Arterial wall perfusion measured with photon counting spectral x-ray CT

SPIE Proceedings | October 4, 2016 | Volume: 9967 | Issue: No issue available | Pages: 99670B

10.1117/12.2238817 | PMID 27807391

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector

SPIE Proceedings | October 3, 2016 | Volume: 9969 | Issue: No issue available | Pages: 99690J

10.1117/12.2236501 | PMID 27795606

Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 | PMID 26835839

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels

Investigative Radiology | January 27, 2016 | Volume: 51 | Issue: 7 | Pages: 421-429

10.1097/rli.0000000000000251 | PMID 26818529

Objectives The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. Materials and Methods A research dual-source PCD-CT scanner was used, where the “A” tube/detector subsystem used an EID and the “B” tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. Results For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. Conclusions The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.