Citations 351

Outcomes in Patients With Cardiovascular Implantable Electronic Devices and Bacteremia Caused by Gram-Positive Cocci Other Than Staphylococcus Aureus

Circulation: Arrhythmia and Electrophysiology | September 18, 2010 | Volume: 3 | Issue: 6 | Pages: 639-645

10.1161/circep.110.957514 | PMID 20852296

Background— Infection is a serious complication of cardiovascular implantable electronic device (CIED) placement and requires device removal for attempted cure. Methods and Results— We studied the rate, risk factors, and outcomes of CIED infection in 74 consecutive patients with bacteremia caused by Gram-positive cocci (GPC) other than Staphylococcus aureus between 2001 and 2007. CIED infection was defined as the presence of signs of infection at the generator site, lead vegetations seen on echocardiography, or microbiological growth from device cultures. Twenty-two (30%) of 74 patients with non– S aureus GPC bacteremia had CIED infections. Coagulase-negative staphylococci (CoNS) accounted for 73% of CIED infections. The rate of CIED infection in patients with CoNS bacteremia was almost 2-fold that of non-CoNS GPC bacteremia (36% versus 20%, P =0.13). The number of leads, the presence of abandoned leads, and prior generator replacement were associated with CIED infection. Among 33 patients without identifiable CIED infection at initial evaluation who did not undergo device removal, 5 (15%) had relapsing bacteremia within 12 weeks of completing antibiotic therapy. CoNS accounted for all relapses, and none had evidence of CIED infection at relapse. Conclusions— Patients with a CIED and bacteremia caused by GPC other than S aureus frequently had evidence of underlying CIED infection on clinical evaluation that included transesophageal echocardiography. This was particularly true among those with CoNS bacteremia. No evidence of underlying CIED infections was identified in the subgroup of patients who did not have manifestations of CIED infection on initial evaluation but subsequently had relapsing bacteremia caused by CoNS.
Effect of Long-Term Right Ventricular Pacing in Young Adults With Structurally Normal Heart

Circulation | April 5, 2010 | Volume: 121 | Issue: 15 | Pages: 1698-1705

10.1161/circulationaha.109.866343 | PMID 20368525

Background— Right ventricular pacing increases the risk of heart failure in adults with structural heart disease. The impact of prolonged right ventricular pacing in adults without structural heart disease is not fully characterized and may depend on interactions of pacing with abnormal substrate predisposing to ventricular dysfunction. Methods and Results— We assessed the effect of right ventricular pacing in patients who underwent pacemaker implantation for isolated congenital atrioventricular block between 1964 and 2005. To assess for immunologic contribution to cardiac dysfunction, outcomes were compared between patients with (Ab + ) and without (Ab − ) antinuclear antibody during adulthood and an age- and sex-matched Olmsted County, Minnesota, population. Of 103 patients (mean±SD age, 32±19 years), 18 were Ab + . Long-term survival free of new heart failure after pacemaker implantation in isolated congenital atrioventricular block patients was worse than in the matched population ( P <0.001). This difference was attributable to the development of heart failure in 12 Ab + patients (67%; P <0.001), without differences between Ab − patients (2%) and the matched population (2%; P =0.7). Compared with baseline, at last follow-up, left ventricular ejection fraction did not decline in Ab − (53±9% to 57±12%) but decreased in Ab + (52±10% to 38±12%; P =0.03) patients. Survival was similar in Ab − patients and the Minnesota population (98%; P =0.7) but worse in Ab + patients (79%; P <0.01). Conclusions— The natural history of patients with isolated congenital atrioventricular block who require pacing depends upon their antibody status. Antinuclear antibody status was a predictor for the development of heart failure and death. Long-term right ventricular pacing alone does not appear to be associated with development of heart failure, deterioration in ventricular function, or reduced survival in Ab − isolated congenital atrioventricular block patients.
Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | June 5, 2008 | Volume: 1 | Issue: 1 | Pages: 30-38

10.1161/circep.107.750315 | PMID 19808391

Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Catheter Ablation for Atrial Fibrillation in Patients With Obesity

Circulation | May 13, 2008 | Volume: 117 | Issue: 20 | Pages: 2583-2590

10.1161/circulationaha.107.716712 | PMID 18474813

Background— Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results— Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped by body mass index (lean, <25 kg/m 2 ; overweight, 25 to 29.9 kg/m 2 ; obese, ≥30 kg/m 2 ). Outcome and quality of life were measured with a general health survey (Medical Outcomes Study 36-item Short-Form General Health Survey [SF-36]); patients were assessed before ablation and at 3 and 12 months after the procedure. Two hundred twenty-eight study patients (44%) were overweight, and 201 (38%) were obese. Twelve months after curative ablation, 72% of patients were free of atrial fibrillation without the use of antiarrhythmic agents; 84% were arrhythmia free when those receiving medication were included. Atrial fibrillation was eliminated in 75%, 72%, and 70% of the lean, overweight, and obese patients, respectively, at 12 months ( P =0.41, trend test). SF-36 scores were lower for patients with higher body mass index ( P <0.05) at baseline. SF-36 scores improved in every functional domain for all body mass index groups after ablation. The mean SF-36 total physical score increased from 59±20 at baseline to 77±19 in 12 months ( P <0.001). The total mental health score improved from 66±18 to 79±16 in 12 months ( P <0.001). Conclusions— Catheter ablation of atrial fibrillation was effective in obese patients. Coexistence of atrial fibrillation and obesity indicated lower SF-36 scores, but the improvement in quality of life was consistent across all body mass index categories.
Atrial Therapies Reduce Atrial Arrhythmia Burden in Defibrillator Patients

Circulation | September 28, 2007 | Volume: 104 | Issue: 9 | Pages: 1023-1028

10.1161/hc3401.095039 | PMID 11524396

Background Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. Methods and Results Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies “on” or “off” and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had ≥30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant ( P =0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted ( P =0.01). Conclusions In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.
Long-Term Progression and Outcomes With Aging in Patients With Lone Atrial Fibrillation

Circulation | June 4, 2007 | Volume: 115 | Issue: 24 | Pages: 3050-3056

10.1161/circulationaha.106.644484 | PMID 17548732

Background— The long-term natural history of lone atrial fibrillation is unknown. Our objective was to determine the rate and predictors of progression from paroxysmal to permanent atrial fibrillation over 30 years and the long-term risk of heart failure, thromboembolism, and death compared with a control population. Methods and Results— A previously characterized Olmsted County, Minnesota, population with first episode of documented atrial fibrillation between 1950 and 1980 and no concomitant heart disease or hypertension was followed up long term. Of this unique cohort, 76 patients with paroxysmal (n=34), persistent (n=37), or permanent (n=5) lone atrial fibrillation at initial diagnosis met inclusion criteria (mean age at diagnosis, 44.2±11.7 years; male, 78%). Mean duration of follow-up was 25.2±9.5 years. Of 71 patients with paroxysmal or persistent atrial fibrillation, 22 had progression to permanent atrial fibrillation. Overall survival of the 76 patients with lone atrial fibrillation was 92% and 68% at 15 and 30 years, respectively, similar to 86% and 57% survival for the age- and sex-matched Minnesota population. Observed survival free of heart failure was slightly worse than expected ( P =0.051). Risk for stroke or transient ischemic attack was similar to the expected population risk during the initial 25 years of follow-up but increased thereafter ( P =0.004), although CIs were wide. All patients who had a cerebrovascular event had developed ≥1 risk factor for thromboembolism. Conclusions— Comorbidities significantly modulate progression and complications of atrial fibrillation. Age or development of hypertension increases thromboembolic risk.
Design and analysis issues in cardiac arrhythmia trials: insights from the Detect Supraventricular Tachycardia Trial

Clinical Trials | February 27, 2007 | Volume: 4 | Issue: 1 | Pages: 74-80

10.1177/1740774506075866 | PMID 17327247

Background The Detect Supraventricular Tachycardia (Detect SVT) trial was a randomized single blind study in subjects receiving a dual chamber implantable cardioverter defibrillator (ICD). The primary goal was to evaluate whether dual chamber enhancements result in greater discrimination between supraventricular tachycardia (SVT) and ventricular episodes when compared to ventricular-only enhancements. Purpose The purpose of this report is to describe our experiences from an analytic perspective, including overall study design, the value of blinded episode review, and the statistical analysis plan. Methods The Detect SVT study was a parallel group study, with blinded central review of all arrhythmia episodes occurring over a six-month period. The primary response was the proportion of inappropriate detections (SVT episodes that are inappropriately classified as ventricular by the device). Results A parallel group design was essential as unplanned crossovers were very differential. The blinded review of episodes was a major use of resources, with over 2300 episodes observed. This review did not materially alter the findings, however, the avoidance of any perceived bias was a major strength. The value of collecting large numbers of episodes on a single subject was found to be minimal. A Kaplan–Meier analysis of the number of SVT episodes until first inappropriate detection was found to add additional information. Limitations The recommendations reported here relate to cardiac arrhythmia trials, or other studies with very similar endpoints. These observations are based on the results of a single trial and should be confirmed in other studies. Conclusions The parallel group design was essential, as was accounting for within-subject correlation in the analysis. The blinded review process was also important, but significant resources could be saved by closing-out episode collection after a fixed number of episodes. Lessons learned from the Detect SVT trial may prove useful to others designing trials in this active research area.
Dual-Chamber Versus Single-Chamber Detection Enhancements for Implantable Defibrillator Rhythm Diagnosis

Circulation | June 13, 2006 | Volume: 113 | Issue: 25 | Pages: 2871-2879

10.1161/circulationaha.105.594531 | PMID 16769912

Background— Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. Methods and Results— Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner. Programming minimized ventricular pacing. The primary end point was the proportion of SVT episodes inappropriately detected from the time of programming until crossover or end of study. On a per-episode basis, 42% of the episodes in the single-chamber arm and 69% of the episodes in the dual-chamber arm were due to SVT. Mortality (3.5% in both groups) and early study withdrawal (14% single-chamber, 11% dual-chamber) were similar in both groups. The rate of inappropriate detection of SVT was 39.5% in the single-chamber detection arm compared with 30.9% in the dual-chamber arm. The odds of inappropriate detection were decreased by almost half with the use of the dual-chamber detection enhancements (odds ratio, 0.53; 95% confidence interval, 0.30 to 0.94; P =0.03). Conclusions— Dual-chamber ICDs, programmed to optimize detection enhancements and to minimize ventricular pacing, significantly decrease inappropriate detection.
Association of Atrial Fibrillation and Obstructive Sleep Apnea

Circulation | July 13, 2004 | Volume: 110 | Issue: 4 | Pages: 364-367

10.1161/01.cir.0000136587.68725.8e | PMID 15249509

Background— Obstructive sleep apnea (OSA) is associated with recurrent atrial fibrillation (AF) after electrocardioversion. OSA is highly prevalent in patients who are male, obese, and/or hypertensive, but its prevalence in patients with AF is unknown. Methods and Results— We prospectively studied consecutive patients undergoing electrocardioversion for AF (n=151) and consecutive patients without past or current AF referred to a general cardiology practice (n=312). OSA was diagnosed with the Berlin questionnaire, which is validated to identify patients with OSA. We also assessed its accuracy compared with polysomnography in a sample of the study population. Groups were compared with the 2-tailed t , Wilcoxon, and χ 2 tests. Logistic regression modeled the association of AF and OSA after adjustment for relevant covariates. Patients in each group had similar age, gender, body mass index, and rates of diabetes, hypertension, and congestive heart failure. The questionnaire performed with 0.86 sensitivity, 0.89 specificity, and 0.97 positive predictive value in our sample. The proportion of patients with OSA was significantly higher in the AF group than in the general cardiology group (49% versus 32%, P =0.0004). The adjusted odds ratio for the association between AF and OSA was 2.19 (95% CI 1.40 to 3.42, P =0.0006). Conclusions— The novel finding of this study is that a strong association exists between OSA and AF, such that OSA is strikingly more prevalent in patients with AF than in high-risk patients with multiple other cardiovascular diseases. The coinciding epidemics of obesity and AF underscore the clinical importance of these results.
Obstructive Sleep Apnea and the Recurrence of Atrial Fibrillation

Circulation | May 13, 2003 | Volume: 107 | Issue: 20 | Pages: 2589-2594

10.1161/01.cir.0000068337.25994.21 | PMID 12743002

Background— We tested the hypothesis that patients with untreated obstructive sleep apnea (OSA) would be at increased risk for recurrence of atrial fibrillation (AF) after cardioversion. Methods and Results— We prospectively obtained data on history, echocardiogram, ECG, body mass index, hypertension, diabetes, NYHA functional class, ejection fraction, left atrial appendage velocity, and medications in patients with AF/atrial flutter referred for DC cardioversion. Forty-three individuals were identified as having OSA on the basis of a previous sleep study. Data regarding the use of continuous positive airway pressure (CPAP) and recurrence of AF were obtained for 39 of these patients. Follow-up data were also obtained in 79 randomly selected postcardioversion patients (controls) who did not have any previous sleep study. Twenty-seven of the 39 OSA patients either were not receiving any CPAP therapy (n=25) or were using CPAP inappropriately (n=2). Recurrence of AF at 12 months in these 27 patients was 82%, higher than the 42% recurrence in the treated OSA group (n=12, P =0.013) and the 53% recurrence (n=79, P =0.009) in the 79 control patients. Of the 25 OSA patients who had not been treated at all, the nocturnal fall in oxygen saturation was greater ( P =0.034) in those who had recurrence of AF (n=20) than in those without recurrence (n=5). Conclusions— Patients with untreated OSA have a higher recurrence of AF after cardioversion than patients without a polysomnographic diagnosis of sleep apnea. Appropriate treatment with CPAP in OSA patients is associated with lower recurrence of AF.